| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP \\"B\\" ) |
| 2 | Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 2.5 sq.mm. + 1x 2.5 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 3 | Wiringfor light/power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single corecable insurface/recessed medium class PVC conduit along with 1No.4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Supplying and fixing 5/6 amps modular switch on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. |
| 5 | Supplying and fixing 5/6 amps modular socket on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. |
| 6 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (Suitable for the BLDC type fans) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 8 | Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240V, onsurface/ recess, complete with tinned copper busbar, neutral busbar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator (16 way , Double door) |
| 9 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \\"C\\"-series Miniature Circuit Breaker suitable for inductive load of single pole in the existing MCB-DB complete with connections, testing & commissioning etc. as reqd. (single pole) |
| 10 | Supplying & fixing 63 amps rating,double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 11 | Supplying and fixing 63 amps rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 12 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 13 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 14 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC Please Enable Macros to View BoQ information |