| 1 | Civil Work : Earth work in excavation of foundation in all kinds of soil including stoney earth and gravels mixed with stone boulders (except sheet rock & boulders requiring blasting) with all leads and lifts including dressing and levelling the bed and depositing the excavated materials at places away from work site with all leads including cost of all labour T&P required for the work etc complete and as per the direction of the Engineer in charge. |
| 2 | Supplying and filling in foundation and plinth with sand including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 3 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge. |
| 4 | Fly Ash Brick masonary with Flyash Bricks of 23cm.x 11cm.x 8cm. size having crushing strength not less than 75 Kg/Cm2. in cement mortar (1:4) in superstructure including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, taxes & royalties of all materials, labour with T&P etc. complete in all respect. |
| 5 | R.C.C. work of proportion M-20 grade having minimum compressive strength in work test of 200 Kg/Cm2 at 28 days using 20 mm and down graded size black hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering and laying concrete and compacting by using vibrators watering, curing for 28 days, centring & shuttering and finishing the exposed surface smooth providing grooves or beads where necessary in all floors including cost, conveyance, royalties and taxes of all materials , cost of all labour with cost of all T&P required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or steel & binding wires and labour charges for strengthening, cutting, bending grills and placing in proper position etc complete as per direction of Engineer-in-Charge. Column base Footing |
| 6 | Column Ground Floor |
| 7 | Column First Floor |
| 8 | Plinth Bend |
| 9 | Beam Ground Floor |
| 10 | Beam First Floor |
| 11 | Lintel Ground Floor |
| 12 | Lintel First Floor |
| 13 | Roof Slab Ground Floor |
| 14 | Roof Slab First Floor |
| 15 | Fly Ash Brick masonary with Flyash Bricks of 23cm.x 11cm.x 8cm. size having crushing strength not less than 75 Kg/Cm2 in cement mortar (1:6) in superstructure including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, taxes & royalties of all materials, labour with T&P etc. complete in all respect.G.F |
| 16 | Fly Ash Brick masonary with Flyash Bricks of 23cm.x 11cm.x 8cm. size having crushing strength not less than 75 Kg/Cm2 in cement mortar (1:6) in superstructure including splays, cuttings, circular moldings, watering & curing for 8 days, cost, conveyance, taxes & royalties of all materials, labour with T&P etc. complete in all respect.F.F |
| 17 | Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-charge. Ground Floor |
| 18 | Cutting, straightening coiled or bent up M.S. Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-charge... First Floor |
| 19 | 20mm thick cement plaster (1:4) finished smooth to brick or stone masonry after racking out joints, including watering, curing, cost, conveyance, taxes, royalties & labour with T&P etc. complete. |
| 20 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor |
| 21 | Providing 12 mm thick cement plaster with cement mortar of mix (1:7) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. First Floor |
| 22 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor |
| 23 | Providing 16 mm thick cement plaster with cement mortar of mix (1:7) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. First Floor |
| 24 | Wall Painting two coats with approved colour of weather seal coat over a coat of primer painted outside surfaces of wall of approved shade and quality etc including shand papering, polishing the surface, all cost, conveyances of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of the Engineer-in-Charge..Ground Floor |
| 25 | Wall Painting two coats with approved colour of weather seal coat over a coat of primer painted outside surfaces of wall of approved shade and quality etc including shand papering, polishing the surface, all cost, conveyances of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of the Engineer-in-Charge..First Floor |
| 26 | Painting two coats with plastic emulsion paint over a coat of primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge Ground Floor. |
| 27 | Painting two coats with plastic emulsion paint over a coat of primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge First Floor. |
| 28 | Finishing wall surface of walls with acrylic putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging changes with cost of all materials, labour etc complete..Ground floor |
| 29 | Finishing wall surface of walls with acrylic putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging changes with cost of all materials, labour etc complete..First floor |
| 30 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all materials & T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. Ground Floor |
| 31 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 11mm as per approved drawing and design with cost of all materials & T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. First Floor |
| 32 | Painting two coats with enamel paints of approved colour, shade over a coat of primer over new/ old wood work and new iron work including all cost of primer and paint, sand papering, polishing the surface, all cost, conveyance of all materials and cost of all labour with T&P complete as per specification & direction of Engineering-in-Charge.Ground floor |
| 33 | Painting two coats with enamel paints of approved colour, shade over a coat of primer over new/ old wood work and new iron work including all cost of primer and paint, sand papering, polishing the surface, all cost, conveyance of all materials and cost of all labour with T&P complete as per specification & direction of Engineering-in-Charge.First floor |
| 34 | Supplying, fitting and fixing vertified tile in floors of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:4) (1 cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge.Ground floor |
| 35 | Supplying, fitting and fixing vertified tile in floors of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:4) (1 cement:5 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge.First Floor |
| 36 | Fixing of Marble tile in Dado with with cement morter(1:3) with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.Groud Floor |
| 37 | Fixing of Marble tile in Dado with with cement morter(1:4) with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.First Floor |
| 38 | Filling F&P with excavated materials including all cost, conveyance,royalty & taxes etc.compete of all materials to work site as per specification approved by the department & direction of Engg-in-charge |
| 39 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. |
| 40 | Dismentalling brick or stone masonry in lime or cement mortar under 3m height.scaffolding, staging charges with cost conveyance cess and royalties of all materials and labour with T&P required for the work etc. complete in all respect in all floors. |
| 41 | 2.5 cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm downgraded size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge Ground Floor |
| 42 | 2.5 cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 7mm downgraded size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge First Floor |
| 43 | Providing and laying 60mm thick factory made cement concrete interlocking paver block with strong vibratory compaction of approved size & design colour & shape including cost of all materials labour T&P etc complete . |
| 44 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. First Floor |
| 45 | E.I:-Supply,Installation, Testing & Commissioning of of 6 Passenger lift gearless with Machine room Capacity,Elevator G+1+TF Floors with ACVVVF drive/Control for constant load of 800 kg ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/kone/Schindler/Thysenkrupp |
| 46 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Polycab/Finolex/L&T/Anchor/Havells/V-Guard) Group-B L.P- 2 F.P- C.B.P- |
| 47 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Polycab/Finolex/L&T/Anchor/Havells/V-Guard) Group-C L.P-3 F.P-1 C.B.P- |
| 48 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches two nos connection(6 modular) (computer board) (make-Anchor/ Legrand /Roma) |
| 49 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Polycab/Finolex/L&T/Anchor/Havells/V-Guard/) 2 X 1.5sq.mm +1 X 1.5sqmm |
| 50 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 51 | 2 X 16sq.mm + 1 X 10sqmm. |
| 52 | Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories |
| 53 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 54 | S/L of 8 SWG Copper wire |
| 55 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.)8way, Double door |
| 56 | Supply and fixing of 5Amp to 32A rating 240V \\"B\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)Single pole (SP) |
| 57 | Single pole and Neutral (SP&N) |
| 58 | S/F of 1P+N and 3P+N SPDs with dedicated protection of the neutral pole discharge the common and differential mode overvoltages that may occur in installations with TT and TNS systems, when there is a voltage surge. Type 1+2 AC Surge Protection Devices,(SPD) High Discharge Current : Imax 50 kA (L – N)70 kA (N – E),Compact Size : Integrated Type-1 & Type-2 protection in small module width. Ideal in all reduced-size plants. Protection : Voltage protection level 1.5 kV, The multi-pole single-piece surge arrester range is adapted for TT, TN-S, TN-C earthing systems. . The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and is 340VAC between phase and earth. Make- Schnider electric/ Havells/ Anchor/ Hager |
| 59 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-100A FP RCCB with 300milli ampere ratings Outgoings- 63 A FPMCB two nos, 32A SP MCB 10KA-3Nos.(Make-L&T/ Schneider/Legrand/Eq) |
| 60 | S/F of 20W 4' LED fitting Surface LED Light fitting (Make-Havels/Philips/Panasonic) |
| 61 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PANASONIC/Havells/WIPRO ,PHILIPS )The luminaire should be Replacement Warranty will be 2 years |
| 62 | S/F of 25W LED street light fitting(Make-Havels/panasonic/Philips/Bajaj/ Crompton) |
| 63 | Supply and fixing of fan (make-Usha/Orient/V-Guard/Khaitan/Havells/Crompton/Almonard/V-Guard)Wall mounted fan 400mm |
| 64 | Supply of PVC/XLPE Aluminium armored cables ISI marked.(Make- Glowstar/ Polycab/Havells)50sq.mm 3 1/2 core |
| 65 | Cable laying on wall surface with steel shaddle 25sqmm to 120sqmm |
| 66 | S/F of 100AMP 25KA MCCB of Hager/Legrand/C&S Make with MS box including both side connections with all complete Please Enable Macros to View BoQ information |