| 1 | Please Enable Macros to View BoQ information |
| 2 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability / authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .LED Street Light fixture with Minimum lumen output 3700 lm |
| 3 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR1.5 Sq. mm 2 Core |
| 4 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .32 mm Dia. |
| 5 | Providing & Fixing of mechanical/digital time switch having following day/week programme and minimum100 hours reserve andAC1rating of 16-20 amperes including making connection,programming conforming to IEC60730-1 and 60730 2-7 etc.as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/work ,refer Annexure\\"A\\"attached with this BSROne day & week reserve (Analog type) |
| 6 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.Pole Power contactors with following AC 3 Rating40 Amp |
| 7 | Providing & Fixing of 240/415V AC MCB with positive isolation of 10 kA breaking capacity(B/C/D tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, ISI marked IS8828(1996)/conforming to IEC60898-12002,IEC60947 2, low watt losses,trip free mechanisum,energy limiting of class3 as per IEC, minimum phase termination capacityof 35sq.mm., conductorl ine load reversibility,IP20contact protection and fitted in existing distribution board/sheets,minimum electrical operation 20,000 upto 20A rating and10,000 upto 63A, 5000 for80A& above rating including making connections,testing etc.as required. OEM shall have submit NABL/CPRI /ERDA accrediated lab type test reports &All as per pre approved byEngineer incharge.For additional technical parameters of product /workreferAnnexure 'A' attached with this BSRSingle Pole MCB (with B/C curve tripping Characteristics)6 A to 32 A rating |
| 8 | Providing & Fixing of 240/415V isolator ISI marked IS:13947 III/conforming to IEC 60947-3, suitable for AC22A utilization category,4KVimpulsewithstandvoltage, truecontact indication, Redcolourdolly/ lever shall have single mould covering overall poles for operation , twopositiondin railmounting, minimum phase termination capacity of 35sq.mm.IP20 contact protection and fitted in existing distribution board/sheet including making connections,testingetc.asrequired.OEM shall have submit NABL /CPRI /ERDAaccrediated lab type test reports &All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSRFour pole isolator 40 A rating |
| 9 | P&Fixing Powder coated CRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes,Din-rail etc. as required.For additional technical parametersof product /work refer Annexure 'A' attached with this BSR1.6 mm thick |
| 10 | Providing&FixingofISOcertified company madeTP&N415Vside handle operated double break fuse switch unit insheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC60947-3:1999 (W/OHBCfuses) includingmakingconnectionswithsuitablelugs, testing etc.asrequired. Appropriate type test certificate/ OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technicalparametersofproducts/work , refer Annexure\\"A\\" attached with this BSR.63 A rating |
| 11 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 12 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR8 SWG G.I. (Hot Dipped) Wire |
| 13 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed UnArrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR10 Sq MM 4 Core |