| 1 | MRL55-BARUWAIL JOYNUL HOUSE TO BARUWIL B0RO MOSHJID |
| 2 | Construction of RCC Bridge Span - 1 x 24.75m at Ch. 15.00m over Nala |
| 3 | Clearing and Grubbing Road LandClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, sapling sand trees of girth upto 300mm, removal of stumps of such trees cut earlier and disposal of unserviceable material sand stacking of serviceable material to be used or auctioned, upto a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness as per Technical Specification Clause 201. [SOR 25-26] [Item No. 2.2(i-a)] i. By Manual Means (a) In area of non thorny jungle |
| 4 | Construction of Embankment with Material Obtained from Roadway CuttingConstruction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5. [SOR 25-26] [Item No. 3.3] |
| 5 | Construction of Embankment with Material Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 [SOR 25-26] [item No. 3.4 (i)] (i) Private Land |
| 6 | Earthwork in Hill RoadExcavation in Hilly Areas in Soil by mechanical means. Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 [SOR 25-26] [item No. 8.3 / II / A] |
| 7 | Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. [SOR 25-26][item No. 3.14 (i)] (i) Private Land |
| 8 | Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. [SOR 25-26][item No. 4.1 (A) (ii)] (A) (iii) For Grading III Material |
| 9 | Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (PugMill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base / base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. [SOR 25-26][item No. 4.9] By Mechanical Means with 1 km lead |
| 10 | Prime Coat :Low porosityProviding and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base/WBM/WMM including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. [SOR 25-26] [Item No. 5.1 (i)] (i) Low porosity |
| 11 | Tack CoatProviding and applying tack coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503 [SOR 25-26][Item No. 5.2 (ii)] |
| 12 | Mix Seal SurfacingProviding, laying and rolling of close-graded premix surfacing material of 20mm thickness composed of 11.2mm to 0.9mm (Type-A) or 13.2mm to 0.9mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10kN static roller and finishing to required level and grades as per Technical Specification Clause 509 [SOR 25-26][Item No. 5.11 II B (ii)] By Mechanical Means, Type B, Bitumen (S-65) |
| 13 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 [SOR 25-26][Item 10.16] |
| 14 | Providing and Fixing PMGSY Logo Board at finishing point of RoadProviding and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint. [SOR 25-26][As per Analysis] |
| 15 | Providing and Fixing Title information Board of PMGSY Project (RCC)Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering.Providing & Fixing Up-gradation Board. [SOR 25-26][As per Analysis] |
| 16 | Providing and Fixing Citizen information Board of PMGSY Project(RCC)\\"A\\"Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint. [SOR 25-26][As per Analysis] |
| 17 | Providing and fixing of typical PMGSY Maintenance information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering. [SOR 25-26][As per Analysis] |
| 18 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703. [SOR 25-26][Item No. 10.10]Ordinary Kilometer stone (precast) [SOR 25-26][Item No. 10.10(ii)] |
| 19 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703. [SOR 25-26][Item No. 10.10]200m Stone (precast) [SOR 25-26][Item No. 10.10(iii)] |
| 20 | Traffic SignsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI Pipe 50mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701 [SOR 25-26][Item No. 10.2 / A / II]600mm equilateral triangle [SOR 25-26][Item No. 10.2 / A / II (ii)] |
| 21 | Traffic SignsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI Pipe 50mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701 [SOR 25-26][Item No. 10.2 / A / II]600mm circular [SOR 25-26][Item No. 10.2 / A / II (iii)] |
| 22 | Rumble StripsProvision of 15 nos.rumble strips covered with premix bituminous carpet,15.2 mm high at centre,250mm wide placed at 1m centre to centre at approved location to control speed, marked with white strips of road marking paint.The rate per sqm of premix carpet and road marking may be adopted from Chapters 5&10 respectively for the quantities calculated from approved drawings. [SOR 25-26][Item No. 10.18] |
| 23 | Cross Drainage :WorksExcavation for StructuresEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. [SOR 25-26][Item No. 9.1 & 11.1 / I (i)] |
| 24 | Plain/reinforced concrete in foundations Providing concrete for plain / reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. With natural Gravel, P.C.C Grade M 10, Nominal mix 1:3:6. [SOR 25-26][Item No. 9.7 / 11.4 / II / A / (i)] |
| 25 | Type B (First Class) BeddingLaying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105. [SOR 25-26][Item No. 9.2 (B) (i)] |
| 26 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding. [SOR 25-26][Item No. 9.3 (ii)] (ii) 1000 mm dia |
| 27 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. [SOR 25-26][Item No. 12.5 / II / C (i)] C. With Natural Gravel (i) RCC Grade M 20, For height upto 5 m |
| 28 | Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203. [SOR 25-26][Item No. 11.4 / II / C / i] C. With natural Gravel PCC Grade M 20 (i) Nominial mix (1:2:4) |
| 29 | Turfing with SodsFurnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309.. [SOR 25-26][Item No. 3.12] |
| 30 | Bridge Works: Dismantling of Structures Dismantling of existing structures like culverts,bridges,retaining walls and other structure comprising of masonry,cement concrete,woodwork,steelwork,including T&P and scaffolding wherever necessary,sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with a lllifts and lead of 1000m as per Technical Specification Clause202. [SOR 25-26] [Item No. 2.5 / I / (c) ] I. By Manual Means (c) Reinforced Cement Concrete |
| 31 | Excavation for StructuresExcavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. [SOR 25-26][Item No. 17.4 / I / (A)] i. In Ordinary Soil (ii) ii. 3.00m to 6.00m depth |
| 32 | Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1200 mm). [SOR 25-26][Item No. 17.29] |
| 33 | Pile load test on single vertical pile in accordance with IS:2911(Part-IV). [SOR 25-26][Item No. 17.37 (a)] (a) Initial and Routine load test |
| 34 | Pile intrigity test intrigity testing of all piles by using of pile driving analyliser or equivalent as approved by Engineer in charge and detailed in specification. Test to be carried out by an approved reputed agency . Item included all incidental work to execute the job.. [N.H. : 2020-21][Item No. 16.55] |
| 35 | Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format, complete as directed by the department.. [SOR 25-26][Item No. 18.43] |
| 36 | Non-destructive testing with rebound hammer for detection of damage zone in reinforced concrete structures and furnishing the findings thereof in proper comprehensible format. [N.H. : 2020-21][Item No. 16.53] |
| 37 | Levelling course for Pile cap. [SOR 25-26][Item No. 17.40] |
| 38 | Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. [SOR 25-26][Item No. 17.38 / C / (ii)] C. RCC Grade M30 Using Batching Plant (ii) Transit Mixer and Concrete Pump |
| 39 | Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. [SOR 25-26][Item No. 17.41 (a)] (a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
| 40 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301. [SOR 25-26][Item No. 14.2] |
| 41 | Providing and laying Pitching on slopes laid over prepared Filter media asper drawing and technical specifications clause 1302. [SOR 25-26][Item No. 14.5 / I] I. Stone Boulder |
| 42 | Providing and laying Filter material underneath Pitching in slopes complete asper drawing and technical specifications clause 1302. [SOR 25-26][Item No. 14.6] |
| 43 | Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. [SOR 25-26][Item No. 17.46 (N) / (G) (b) Case II] G. RCC Grade M30 (b) Height 5m to 10m Case-II - With Batching Plant, Transit Mixer and Concrete Pump |
| 44 | Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. [SOR 25-26][Item No. 17.46 (N) / (H) (b) Case II] H. RCC Grade M 35 (b) Height 5m to 10m Case II - With Batching Plant, Transit Mixer and Concrete Pump |
| 45 | Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent). [SOR 25-26][Item No. 17.47] |
| 46 | Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawings and technical specification Clause 1207.1 [SOR 25-26] [Item No. 17.55] |
| 47 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. [SOR 25-26] [Item No. 17.50 / A] (A) Granular material |
| 48 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. [SOR 25-26][Item No. 12.9] |
| 49 | Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. [SOR 25-26] [Item No. 17.58 (N) / D/ Case II / (ii) / b] RCC/PSC Grade M35For T-beam & slab Using Batching Plant, Transit Mixer and Concrete Pump. Height 5m to 10m |
| 50 | Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. [SOR 25-26][Item No. 17.59 (a)] (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
| 51 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. [SOR 25-26][Item No. 17.61] |
| 52 | Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. [SOR 25-26] [Item No. 17.64] |
| 53 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). [SOR 25-26][Item No. 17.77] |
| 54 | Drainage spouts complete as per drawing and technical specifications Clause 1209 [SOR 25-26][Item No. 17.67] |
| 55 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification [SOR 25-26][Item No. 17.68] |
| 56 | Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification [SOR 25-26][Item No. 17.69 (a)] (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) Please Enable Macros to View BoQ information |