| 1 | Supply and painting of the exterior surface of the buildings which includes masonry walls, RCC columns, beams, sunshade, down take pipe, roof gutter, jally and other masonry surface etc Details as per Sl No 1 in BOQ |
| 2 | Providing painting for all fittings and accessories including wooden windows, doors, ventilators, MS supports & frames, grills, gates and all other parts need to be painted at suit to site Details as per Sl No 2 in BOQ |
| 3 | Supply & painting interior surface of buildings including masonry walls, RCC columns, beams, ceiling, gable wall, sun shades, roof gutter, PVC pipes etc.Details as per Sl No 3 in BOQ |
| 4 | Supply & painting interior surface of plant buildings including masonry walls, RCC columns, beams, ceiling etc., as directed by Engineer in charge, prepared & applied as per manufacturer’s recommendation with one coat of epoxy primer (dual pack) and two or more coats of epoxy finish paint. Details as per Sl No 4 in BOQ |
| 5 | Repair of cracks (interior & exterior) of more than 1mm width at masonry surface of structure in buildings Details as per Sl No 5 in BOQ |
| 6 | Providing masonry repair work in structure using CM 1:5, standard size concrete blocks or bricks of good quality after chipping & removal of damaged structure including racking out of joints, finishing to proper lines and levels . Details as per Sl No 6 in BOQ |
| 7 | Providing plastering in CM 1:5 mixing & application of mortar, finishing smooth to proper line & level for masonry wall, 12mm average thick, using good quality plastering grade M-sand Details as per Sl No 7 in BOQ |
| 8 | Supply and painting of MS structural roof trusses, rafters, purlins, bracings, stiffeners, joint plates, columns and other roof supports, accessories etc., with one coat of epoxy based primer Details as per Sl No 8 in BOQ |
| 9 | Supply & fixing PVC pipe of 140 mm dia or nearest, 4 kg/cm2 pressure rating for rain water down take from roof gutter, including suitable specials such as bends, tees, elbows, solvent cement etcDetails as per Sl No 9 in BOQ |
| 10 | Supply, fabrication & erection of MS structural for replacement of damaged structural members in steel structure such as purlins, rafters, cleats, ties, column supports, bracings, stiffeners, monkey ladder, stiffener, gusset plates, platform supports etc Details as per Sl No 10 in BOQ |
| 11 | Dismantling of masonry structure, floor, slab, columns, beams (concrete/brick/rubble) etc. Details as per Sl No 11 in BOQ |
| 12 | Providing & laying of Reinforced Cement Concrete RCC (M25 Grade as per IS 456) for repair works in masonry surface Details as per Sl No 12 in BOQ |
| 13 | Supply & Laying reinforcement High yield strength deformed (HYSD) bars Fe 500 grade, cutting to required size, . Details as per Sl No 13 in BOQ |
| 14 | Providing form work / leak proof shuttering for all RCC & micro concrete works Details as per Sl No 14 in BOQ |
| 15 | Engaging diamond wheel core cutting machine for providing 25mm -150mm dia hole in masonry structure to a thickness of 300mm for drainage holes on floor Details as per Sl No 15 in BOQ |
| 16 | Supply & Pouring micro concrete of M40 grade (min.) at the locations to be repaired in RCC beams & columns, after completely removing rust particles all-round the existing re-bar Details as per Sl No 16 in BOQ |
| 17 | Supply & application (re-plastering) of dual shrinkage compensated fiber reinforced thixotropic repair mortar (of minimum compressive strength 40N/mm2 in 28 days in RCC slab ceiling by chipping & removing existing damaged concrete layer Details as per Sl No 17 in BOQ |
| 18 | Fabrication, Supply & fixing of gates / doors / stands using GI hollow sections (square/rectangular/round) in position for panel board / operator cabins, plant building etc. & other locations of various buildings inside factory premises or disposal yard, storage godown as directed by Engineer in charge. Details as per Sl No 18 in BOQ |
| 19 | Labour charges for cutting and fixing of wooden chequered boards/ PVC foam board / polycarbonate sheet for working platform, operator cabins, MCC panel boards Details as per Sl No 19 in BOQ |
| 20 | Labour charges for cleaning of roof gutter, terrace / roof area, floor drainage, cutting of plants & vegetation on masonry structure etc., from the building, disposing all waste material in disposal yard etc. Details as per Sl No 20 in BOQ |
| 21 | Labour charges for repairing of wooden windows / doors / ventilators in buildings inside the factory premises by engaging skilled carpenter Details as per Sl No 21 in BOQ |
| 22 | Dismantling of MS structural by appropriate cutting method (cold cutting/gas cutting etc.).The work includes cutting, removing of MS structural like columns, beam, platform, purlins, rafters, cladding, louvers etc Details as per Sl No 22 in BOQ Please Enable Macros to View BoQ information |