| 1 | Compound walling:- Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kind of soil |
| 2 | ordinary rock 30% |
| 3 | hard rock 20% |
| 4 | Providing and Laying soling of aggragate 40mm thick including ramming of soil etc. |
| 5 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Random Rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) and curing complete at window sills, ceiling level and the like: Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 7 | Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete |
| 8 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 9 | Solid block (boundry wall) |
| 10 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size). |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand) |
| 13 | Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement |
| 14 | Structural steel work riveted, bolted or welded in built up sections, trusses andframed work, including |
| 15 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 16 | Providing and fixing traditionally carved wood work (Shingstak) over doors andwindows including all accessories as per the direction of the Engineer in-charge,complete with; 2nd class kail wood |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 18 | Painting the top wall with ancient architectur design with approved quality paint of standard quality. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of formwork for : Foundations, footings, bases for columns |
| 20 | Columns, piers, abutments, pillars, posts and struts |
| 21 | CARRIAGE: cement from average lead of 55 km by MT |
| 22 | sand from average lead of 55 km by MT |
| 23 | Aggregate from avg lead of 55 km by MT |
| 24 | Manual carriage from average lead of 250Mtr by MT: Cement |
| 25 | Aggregate |
| 26 | Stone |
| 27 | Bricks |
| 28 | Washroom: Earth work in excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 70% |
| 29 | Hard rock 30% |
| 30 | Filling available excavated Earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 31 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand |
| 32 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 33 | Soiling stone column excavation |
| 34 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 37 | Columns, pillars, piers, abutments, posts and struts. |
| 38 | Lintel, beams, plinth beam, girders, bressumes and cantilever. |
| 39 | Suspended floors, Roofs, Landings, Balconies and Access Platforms. |
| 40 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize) |
| 41 | Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions <1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTMD 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 clasS A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer- in-Charge |
| 42 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood |
| 43 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash O.DESCRIPTION UNIT RATE ₹ shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window double panels with S.S. friction hinges (300x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqmupto1.50 sqm) |
| 44 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.250 x 19 x 1.9 mm |
| 45 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. |
| 46 | Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete |
| 47 | Providing and fixing double glazed unit (DGU) inclu conforming to 6mm thick taughen glass on either side with g 12mm air gap including providing EPDM gasket, and shall be processed for reputing glass processer. |
| 48 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 49 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 50 | Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. |
| 51 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 52 | Providing and applying white cement based putty of average thickness 1 mm ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete.2 mm thick |
| 53 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 54 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter |
| 55 | Providing and fixing 150 mm bright finished floor brass door stopper withrubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 56 | Providing and fixing 85x42mm chromium plated brass pull bolt lock with necessary C.P. brass screws, nuts, bolts and washers etc. complete |
| 57 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. |
| 58 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 59 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) W1 Polyester powder coated aluminum (minimum thickness ofpolyester powder coated 50 microns) W1 |
| 60 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :250X10MM |
| 61 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparrent or dyed to required colour and shade with necessary screws etc. complete.100 mm |
| 62 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to bepainted with polyurethane primer (fittings to be paid separately). 18 mm thick |
| 63 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete : 100 mm |
| 64 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm |
| 65 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 66 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 67 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls andfloors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integraltype foot rests.Orissa type pattern W.C Pan of size 580x440 mm |
| 68 | Providing and fixing white vitreous china pedestal for wash basin completelyrecessed at the back for the reception of pipes and fittings. |
| 69 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32mm C.P. brass waste of standard pattern, including painting of fittings and rackets, cutting and making good the walls wherever require :17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps. |
| 70 | Mirror of superior make glass 60x45 cm |
| 71 | UPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe metre.75mm |
| 72 | 110mm |
| 73 | uPVC single equal Tee (without door) 75x75x75 mm |
| 74 | 110x110x110 mm |
| 75 | providing and fixing the aluminium sheet, chicken mesh, glass wool k flex and heat tape over the external pipe including the cost of fixing the materials |
| 76 | providing and fixing the k flex and heat tape over the internal pipe including the cost of fixing the materials |
| 77 | providing the insulation of aluminium cover chicken mesh glass wool around the water tank complete job |
| 78 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylenerandom fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes thecost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Chajge. (Concealed work including cutting chases and making good the walls etc.,) PN-16 Pipe, 25 mm OD (SDR-7.4) |
| 79 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 80 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 81 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 82 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 83 | C.P. brass Toilet paper holder of standard size |
| 84 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 85 | Towel rail C.P. brass 600 x20 mm together with a pair of C.P. brass brackets to fit the size of towel rail |
| 86 | Rectangular shape 600x450 mm precast R.C.C. manhole cover. |
| 87 | Providing and fixing 25 ltr instant water Gyser including cost of fixing all complete job |
| 88 | Providing and fixing FRP water Reservior of 1000 lts capacity of any manifucture brand like sintex etc. Including cost of valves etc all. |
| 89 | Supplying installation testing and commissioning of 2.5HP pump set along with all accessories including 14mm nylon wire rope HDPE pipe adopter,support clamps,GI bends including connections etc as required(Head not less than 200m,discharge minimum 2000 litre per hour/maximum 8000 ltr per hour(Make:- Similar to KSB CORA 100 + UMA 100/Kirloskar/Calama/ Crompton) |
| 90 | Float glass panes 5 mm thick glass panes (weight not less than 12.5 kg/sqm |
| 91 | Structural steel work riveted, bolted or welded in built up sections, trusses andframed work, including |
| 92 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. |
| 93 | Providing and fixing shower rose of approved quality. |
| 94 | CARRIAGE OF MATERIAL::Cement from average lead of 55 km by MT |
| 95 | sand from average lead 30 km by MT |
| 96 | aggreegate from average lead 30 km by MT |
| 97 | Manual carriage:from avg lead of 250 Mtr: Cement |
| 98 | Aggregate |
| 99 | Stone Please Enable Macros to View BoQ information |