| 1 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 2 | One or more coats on old work. |
| 3 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 4 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 5 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 6 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 7 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 8 | Old work (one or more coats) |
| 9 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 10 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 11 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 12 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 13 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 14 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 15 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 16 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 18 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 19 | 12 mm cement plaster of mix : |
| 20 | 1:6 (1 cement: 6 fine sand) |
| 21 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 22 | 1:6 (1 cement: 6 fine sand) |
| 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 24 | 15 mm nominal outer dia .Pipes. |
| 25 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 26 | For thickness of tiles 10 mm to 25 mm |
| 27 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 28 | W.C. pan with ISI marked white solid plastic seat and lid |
| 29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 30 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 31 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 32 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 33 | Flexible pipe |
| 34 | 32 mm dia |
| 35 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 36 | Rectangular shape 453x357 mm |
| 37 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 38 | Providing and fixing toilet paper holder : |
| 39 | C.P. brass |
| 40 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 41 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 42 | 45 cm length |
| 43 | 15 mm nominal bore |
| 44 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 45 | 15 mm nominal bore. |
| 46 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 47 | 15mm nominal bore |
| 48 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 49 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 51 | Size of Tile 600x600 mm |
| 52 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 53 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 54 | 110 mm diameter |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 56 | 110 mm bend |
| 57 | Providing and fixing PVC Nahnitrap of size 100x50 mm i/c jointing with PVC solution and fixing in proper position embediding in CC 1:1.5:3 ( 1cement: 1.5 coarse sand: 3 stone aggreegare 20 mm nominal size) complete as per direction of Engineer-in-charge . |
| 58 | Repair of Manhole cover slab by dismanteling existing damaged RCC slab providing new reinforcement as per direction of Engineer-in Charge ,centring shuttering and laying of RCC slab of area 1.0X1.20 m 20 CM thick with concrete mix 1:1.5 :3 (1 cement: 1.5 coarse sand: 3 stone aggregare 20 mm nominal size)and fixing existing cover in slab with frame complete as per direction of engineer-in -Charge |
| 59 | Closing of exhuast fan round opening of 600 cm dia with bricks and cement mortar 1:6( 1cement: 6 coarse sand) including finishing both sides with cement mortar 1:4 (1cement: 4 coarse sand) including scaffolding ,labour and all T&P involved complete as per direction of Engineer -In-Charge. |
| 60 | Repair of wooden door/windows, kitchen cabinet shutters by chisling ,cutting and by Proving nails etc to make the wooden door shutter workable comlete as per direction of engineer in charge |
| 61 | Dismantling and dismembering aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material like tubular members,glass,board ,beading etcwith in 50 meters lead as directed by Engineer-in-charge. |
| 62 | Refixing of dismembered aluminium/modular partition, glass panes and particle board in the required new position,(excluding doors & windows) making into required shape & size as per site conditions including cost of rubber gasket,cleats, labour steel screws,etc. wherever required all complete, and as per the direction of Engineer-in Charge. |
| 63 | Shifting of Aluminium tubular sections, beadings etc. obtained from dismantling i/c aluminium doors with all fittings, sections with 12mm laminated board and 5mm Thick Glass from Ist Floor of TE Bldg. Ramdarbar to basement of TE Sector-34 Chandigarh, transportation by mechanical means including Loading and Unloading complete i/c Lifting and all leads complete as per directions of Engineer-in-charge. Please Enable Macros to View BoQ information |