| 1 | Dewatering of soak well , septic tanks by using mechanical pump diesel driven with fuel operator and crew of water etc at site all as specified and directed by Engineer in charge.Note for item no-01 to 061.The cleaning shall be carried out with mechanized operation by means of diesel / electric operated vehicle mounted hydraulic operated high pressure suction -cum -jetting machines fitted with pump of required capacity and the sludge sucked out with Super Succer Machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site land at any distance and without any additional cost. 2. The sludge deposited in sewage line shall be fully cleaned and disposed off the same outside the MOD land at any distance and without any additional cost , on the same day when it was taken out.The job shall be carried out with safety precaution equipment and with strict supervision .3. During the mechaized operation , the service provider /Contractor shall be equiped with Gas monitor , nylon rope ladder , torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine . 4. The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provision of water for jetting & removal of sludge /silt /liquid /mud & sand (in foul position )etc. 5. The contractor shall engage the above mentioned T & P and intimate to Enginner - In -Charge in writing with Machine No./ Vehicle No. etc for their record and prior approval .6. A Register shall be maintained showing the Machine No /Vehicle No. and their deployment at site mentioning time and date duly sighned by concern JE , Engr -in- charge and contractor and the same register shall be produced while claiming the payment by the tenderer . |
| 2 | Cleaning of soak well, septic tanks by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at the location notified by the local Municipal Corporation/ Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soil and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. |
| 3 | Cleaning of blockage of 150mm bore sewer lines (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding of sewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well all as specified and directed . |
| 4 | Cleaning of all manholes upto 3.00 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. |
| 5 | Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. |
| 6 | Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC's, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes of any dia by rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board). To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helper from 0900 hours to 1700 hours at Complaint cell of AGE B/R-II area mentioned in the contract on daily basis, with manual/ pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), complete all as specified and directed. |
| 7 | Excavation in trenches n. exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier hole etc not exc 10 sqm on plan and not exc 1.5 m depth and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Returning filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and directed. |
| 9 | Removing of excavated materials to a distance 1.5km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes (SGSW,DWC, AC or RCC) of 150mm bore sizes, set in cement mortar complete all as specified and directed. |
| 11 | Demolition and breaking up drain pipes (SGSW,DWC, AC or RCC) of 100mm bore sizes, set in cement mortar complete all as specified and directed. |
| 12 | M&L for salt glazed stone ware drain pipe grade A 150 mm internal dia (ISI marked) laid in trenches and jointed in cement mortar (1:1) and tested complete all as specified and directed. |
| 13 | S & F for reinforced concrete pipes, class NP-2, 150mm internal dia laid and jointed complete with collers, complete all as specified and directed. |
| 14 | S&F for DWC (Double Wall Corrugated) Sewerage HDPE Pipes as per IS 16205 of Size 100 mm internal dia laid in trenches and jointed and tested as per manufacturer instruction complete all as specified and directed. |
| 15 | S&F for DWC (Double Wall Corrugated) Sewerage HDPE Pipes as per IS 16205 of Size 150 mm internal dia laid in trenches and jointed and tested as per manufacturer instruction complete all as specified and directed. |
| 16 | M&L for cement concrete type C2 (1:3:6) with 100 mm thick bedding to drain pipes of 150 bore sizes including packing under and hunching against the sides of pipes after they are laid and tasted; in cement concrete complete all as specified and directed. |
| 17 | M&L for cement concrete type C2 (1:3:6) with 150 mm thick bedding to drain pipes of 150 bore sizes including packing under and hunching against the sides of pipes after they are laid and tasted; in cement concrete complete all as specified and directed. |
| 18 | M&L for Cutting into existing manholes for connecting new drains pipes of 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching complete all as specified and directed. |
| 19 | M&L for Cutting into existing manholes for connecting new drains pipes of 100mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching complete all as specified and directed. |
| 20 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 21 | M & L, brick work with fly ash bricks Modular bricks size, straight or curved on plan exc. 6.0M mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 22 | M & L, brick work with fly ash bricks Modular bricks size, straight or curved on plan exc. 6.0M mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 23 | All as per Item No 21 above but except bricks. (Bricks recd from demolition) complete all as specified and directed |
| 24 | M & L for brick work with fly ash bricks, Modular bricks size, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed. |
| 25 | Taking down of cement plaster in any description on brick or stone wall etc, incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 26 | M&L for rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, complete all as specified and directed of Engineer-in-Charge. |
| 27 | Repair to plaster by using readymix mixture of thickness 15 mm and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 28 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 29 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thick above or below ground level complete all as specified and directed. |
| 30 | M&L for 50mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor surface finished even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate as in Surface channel or drains including necessary form works , stops ,moulds etc complete all as specified and directed. |
| 32 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed. |
| 33 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 34 | M & L for RCC Type B1 1:2:4 using 20 mm graded stone agg as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 35 | M&L for Precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, shelves and similar articles set in CM 1:4 complete all as specified and directed. Note:- Reinforcement shall be measured & paid separately |
| 36 | M&L for cement concrete 1:2:4, type B-2, using 40 mm graded stone aggregate as in flooring,in foundations, filling and mass concrete complete all as specified and directed. |
| 37 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintel up to 1.5m clear span, cills, steps, bands, coping including weathering, slightly rounded or champhered, angle and throating as directed and other similar work all as specified including necessary form work complete all as specified and directed. |
| 38 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed. |
| 39 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide complete all as specified and directed |
| 40 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 41 | ditto all as per Item No 40 above but 6mm to 8mm dia. complete all as specified and directed. |
| 42 | ditto all as per item No 40 above but 5mm dia and over upto and including 10 mm dia in stirrups,apacers and binders.complete all as specified and directed. |
| 43 | M&L for factory made RCC man hole cover /drain cover with cover frame comprising of 75mm thick cover, including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole, demolition of existing coverwith cover frame and removal of debris from site complete all as specified and directed. Note : The factory made RCC cover shall be ISI marked and as approved. |
| 44 | Removal of debrish exc. 1.50 km but not exc. 5 km and depositing where directed at a level complete all as specified and directed. |
| 45 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 46 | M & L glazed ceramic joint free coloured tiles in vertical surfaces 600x300x7mm thick, set and joiunted in neat cement slurry and pointed in coloured cement to match over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed. |
| 47 | M & L coloured Non Skid ceramic jointless tiles of 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but not exc. 0.18 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed. |
| 48 | M&L for non skid ceramic (coloured) jointless tiles of 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed. |
| 49 | Dismantling of stone slabs and tiles laid dry of any description or thickness in floor, aprons etc complete all as specified and directed. |
| 50 | M&L for machine pressed precast concrete interlocking paver block, ruberised, glossy finish any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed. |
| 51 | M&L for sand under floor or paving laid in layers not exc 15cm thick, spread, levelled and rammed complete all as specified and directed. |
| 52 | M & L for coloured chequered tile glass moulded glossy finished of size 300x300x25mm thick set and jointed in neat cement slurry and pointed with mixture of white & gray cement in equal portion & no pigment over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 53 | M&L for heavy duty exterior vitrified tiles of size 300 x300x10mm laid over 15 mm thick screed bed in CM 1:6 jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tile complete all as specified and directed |
| 54 | Dismantling fencing post of any size and any description complete all as specified and directed |
| 55 | Dismantling of chain link fencing fencing wire mesh, any type of any description complete all as directed |
| 56 | Excavation in post hole (or similar hole) each n exc 0.50 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer n. exc 25 cm etc and getting out soft/ loose soil complete all as specified and directed |
| 57 | M&L for PCC 1:3:6 type B2 using 40 mm graded stone aggregate as in foundations filling and mass concrete filling, etc complete all as specified |
| 58 | S&F for mild steel work as in posts and struts etc in fencing including cutting tops to shapes as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified |
| 59 | S&F mild steel framed work as in doors / gates / steel frames / chowkats etc. of angle or other section with gusset plates, rails, braces, etc., complete conforming to Grade E - 410 (Fe 250), drilled for fixing of steel sheeting or other covering including necessary welding etc and fixing in position complete, all as specified & directed. |
| 60 | S&F in repair galvanised two strand steel barbed wire with 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rail strain-ing bolts including, securing or tying at crossing with and provision of galvanised mild steel wire, staplesor steel pins, etc. complete all as specified and as directed . |
| 61 | Supply only Chain Link MS galvanized fencing of any size and any type as approved complete all as specified and directed |
| 62 | Fixing Only Chain Link fencing including line wires, any mess, size and type to any type of standards, rails, straining bolts, etc including provision of binding wires, complete all as specified and directed |
| 63 | M&L for two coats of synthetic enamel paint over a coat of Red oxide primer surfaces including preparation of surfaces all as specified and directed. |
| 64 | M&L for preparing new plastered surface of wall and applying three coats of white wash in any height of building complete all as specified and directed. |
| 65 | M&L for preparation of new plastred surfaces of and applying two coats of cement base paint of approved shade/ tint, complete all as specified and directed. |
| 66 | Dismantling of Trellis work (Jafri)/RCC jali complete all as specified and directed |
| 67 | M&L for Providing precast cement concrete type B-O using 12.50 mm graded stone aggregate louvres and jallies set in CM 1:4, 35mm thick (measured solid), including all mould- ings but excluding framecomplete all as specifed and as directed. |
| 68 | Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete, all as specified & directed. |
| 69 | S&F of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. |
| 70 | S & F of Factory made single extruded WPC (Wood PolymerComposite) solid plain/ decorative flush door shutter of 30mm sizecomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 71 | S & F, 100 mm size butt hinges, stainless steel, and fixed all as specified and directed. |
| 72 | S&F Aluminium anodised barrel tower bolts of extruded section 150mm long complete, |
| 73 | S&F Aluminium handles cast type anodised of 150mm complete. |
| 74 | Dismantling loose /disintegrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and dobbing out with PCC 1:1:5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed. |
| 75 | Demolition of cement concrete (unreinforced) of any description from sunken floor (ground or Ist floor) and removing and depositing materials exc 150 mtrs and n.exc 250 mtrs away complete all as specified and directed. |
| 76 | M&L for mass concrete filling using PCC (1:5:10) type E2 in sunken floor complete all as specified and directed. |
| 77 | M&L for 20mm thick cement plaster in CM 1:4 mixed with water proofing compound @ 3% and applying water proofing treatment on sunken portion with acrylic based polymer modified cementitious composit compound as specified and approved & cement slurry two layers, Ist layer @ 0.488 Kg/Sqm mixed with composit compound @ 0.253 Kg/Sqm & the second layer slurry @ 0.242 kg/Sqm mixed 0.126 Kg of compound complete with min 4 hours allowed to air cure between these layers and applying 200 u polyfilm with adhesive complete all as specified and directed. |
| 78 | Taking down rain water pipes (any size or pattern) incl all fittings, shoes, bends, swan neck etc complete all as specified and directed. |
| 79 | S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed. |
| 80 | S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed. |
| 81 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 82 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 83 | S&F of 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed. |
| 84 | S&F of 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed. |
| 85 | S & F in repair PVC (SWR) floor trap of size 110/110mm, complete all as specified and directed. |
| 86 | S & F in repair for 110mm PVC (SWR) WC connector bent type, complete all as specified and directed. |
| 87 | S&F in repair 110mm bore PVC (SWR) bend, any radius, complete all as specified and directed. |
| 88 | S&F in repair 75mm bore PVC (SWR) bend, any radius, complete all as specified and directed. |
| 89 | S&F in repair 110mm bore PVC (SWR) vent cowl, complete all as specified and directed. |
| 90 | S&F steel water tubes medium grade, galvanised with all fittings 15mm bore fixed complete to concilled in walls and ceiling or laid in floors including taking up or down steel tubing and connections, 15mm bore complete all as specified and directed. |
| 91 | S&F steel water tubes medium grade, galvanised with all fittings 20mm bore fixed complete to walls and ceiling or laid in floors trenches including taking up or down steel tubing and connections, 20mm bore complete all as specified and directed. |
| 92 | S&F in repairs vitreous china squatting pan \\"Orissa\\" pattern size 580mmx440mm white with integral foot rests including connection to trap, and to flushing pipe, anti syphonage pipe, etc complete making good to floors and complete all as specified and as directed. |
| 93 | S & F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete all as specified and as directed. |
| 94 | S&F in repair for plastic water closet seat cover , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 95 | S&F as in repair PVC valve less, syphonic action type flushing cistern, ISI marked, 10 lit capacity, low level white with inlet, ball valve , float and handle including brackets and flush pipe fixed etc complete all as specified and as directed. |
| 96 | S&F in repair vitreous China Urinal, bowl type (back or corner wall type) size of 465x355x265mm white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinalto plugs with and including 60 mm long brass screws, pointing around urinal back in cement, complete all as specified and directed. |
| 97 | M&L in repair for Vitreous china wash basin, white, flat, back, size 580x450mm excluding taps, waste, china & plug & porcelain stopper but including brackets complete all as specified and directed. |
| 98 | S&F, in repair for waste coupling, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed 32mm bore, complete all as specified and directed. |
| 99 | S&F, in repair 32 mm bore Low density PVC flexible pipe for Wash hand basin/sink etc complete all as specified and directed. |
| 100 | S & F, in repair PVC connections 15 mm size with PTMT nuts of length 450 mm all as specified and directed. |
| 101 | S & F in repair CP grating with or witout waste hole size 100 mm fixed with white cement in tiles flooring complete all as specified and directed. |
| 102 | S & F in repair stainless steel sink coupling size 75/100mm dia all as specified and directed. |
| 103 | Dismantling RCC/PVC water tanks and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., all as directed. |
| 104 | S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks, white colour, Triple layered (cylindrical, vertical with closed top) hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete, all as specified and directed. |
| 105 | S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed. |
| 106 | S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, complete all as specified and directed. |
| 107 | Dismantling of AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges complete all as specified and directed. |
| 108 | Dismantling timber scantlings framed work 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 109 | Dismantling timber scantlings framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position complete all as specified and directed. |
| 110 | S&F of Pre-painted galvalume aluminium zinc coating base corrugated steel sheets 0.50mm thick of any approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 111 | S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 112 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 113 | S&F rolled steel section as in main and cross beams, hip and jack rafters, purlin where connected to common rafters and similar works conforming to grade Fe 410-w (Gde-E-250 quality A) complete, all as specified and directed. |
| 114 | Dismantling wall and ceiling board( fiber, plug, insulation, etc) or insulation boards/ slabs/ blankets, any thickness incl cover fillets. |
| 115 | M&L false ceiling with 4 mm thick E-board white prelaminated set embossed reinforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600 x 600 mm having 24 mm wide T- section, runner made of 0.33 mm GI sheet and angle made of 0.45 mm GI sheet, suspended with 2 mm dia GI wire complete all as specified and directed. |
| 116 | S&F Solid PVC Wall Lining consisting of 5mm thick Panel with wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 117 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified Please Enable Macros to View BoQ information |