| 1 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 2 | Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule 'A' Sec-I. |
| 3 | Lump sum price worked out by the contractor for RAMP/ PATHWAY/ HARDSTANDING WORKS as listed in Schedule 'A' Sec-II. |
| 4 | Lump sum price worked out by the contractor for FENCING/ STEEL GATE WORKS as listed in Schedule 'A' Sec-III. |
| 5 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Sec-IV. |
| 6 | Lump sum price worked out by the contractor for RAIN WATER HARVESTING as listed in Schedule 'A' Sec-V. |
| 7 | Lump sum price worked out by the contractor for EXCAVATION AND EARTH as listed in Schedule 'A' Sec-VI. |
| 8 | SCHEDULE 'A' SEC-VII – Misc Items |
| 9 | M&L for Aluminium Profile sheet for gate etc of any thickness and colour as approved complete fixed to frame work all as specified and directed. |
| 10 | S&F Aluminium Composite Panel (ACP) sheet 3mm thickness of approved colour/shade fixed to frame work at height of 3 to 5 mtrs complete all as specified and directed. |
| 11 | S&F 3D Acrylic LED letters/ alphabets with module light of size 300mm height and 50mm thickness of approved colour/ shade/ font/ pattern fixed to frame work at height of 3 to 5 mtrs all as specified and directed. |
| 12 | M&L for factory made rubber moulded pre-cast cement concrete block of size 300x300x100 thick of garde M-30 as in drainage channel/ saucer drains at edges and 75mm at centre with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar with & including in CM 1:4 complete with joints to match including embedding in the ground to depths indicated and tamping ground around and also for removing any surplus spoil to a distance n. exc. 50 mtrs complete all as specified and directed. |
| 13 | M&L for pre-polished machine pressed rubber moulded precast cement concrete intelocking modular paver block in combo design of 200x100x60mm & 100x100x60mm or 300x200x60mm, 200x200x60mm & 200x100x60mm of approved shades of colour/ pigmnet in aprroved pattern with minimum M-35 Grade including over including 25mm thick layer of sand cushion complete all as specified and directed. |
| 14 | Dismantling Wall and false ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness/description, including cover fillets/frame work of any description or complete all as specified and directed. |
| 15 | S&F false ceiling of 12.5mm th gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer's instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by AO and including supply and fixing of items all as specified as below :-Note : The complete item shall be got executed through the authorised applicator of manufacturer only complete all as specified and directed. |
| 16 | S&F Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. |
| 17 | S&F Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. |
| 18 | S&F Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} |
| 19 | S&F Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. |
| 20 | S&F Single layer of 12.5mm tapered edge Plain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. |
| 21 | Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. |
| 22 | M&L for applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 0.50 to 1.50 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 23 | M&L for preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceilings surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 24 | S&F anodised aluminium snap grid frame work (size of grid 605x605mm) for false ceiling all as specified including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 25 | M&L for 12 to 12.50mm thick semi-perforated/pin holed particle board/tiles, 600x600 ± 5 mm in size fixed in false ceiling as per manufacturer's instructions to existing frame work or on snap grid as in repairs complete all as specified and directed. |
| 26 | M&L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring) Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost. |
| 27 | All as per serial item No 20 above herein before but one 3 pin, socket outlet, 5 amps, independent, with cables 1.5 sq.mm size complete all as specified and directed. |
| 28 | Supply and Fixing LED light fittings 1 x 36 Watt, 230 V, AC decorative strip type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as specified and directed. |
| 29 | M&L switch piano, flush type single pole, one way 5 Amp complete all as specified and directed |
| 30 | M&L for Socket outlet 3 pin, 5A, flush type complete all as specified and directed. |
| 31 | M&L Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, retuning filling, Removal of surplus soil, charcoal and common salt mixed refilling of soil etc all included complete all as specified and directed. |
| 32 | S&F ceiling fan BLDC type alongwith fan regulator and all connected accessories complete all as specified and directed. |
| 33 | M&L for drilling of bore of size 150 mm dia by direct rotary mechanical system for injection well in any kind of soil strata including hard stone / boulders all as specified and directed. Note : 01Nos of bore to be done, each of depth upto 40 mtrs. The drilling carried out with Rotary drilling method (Direct/Reverse) to the depth of 40 Metre. The bore hole should be electrically logged for precise delination of aquifers (coarse granular and fine grained sediments) to be taped for recharging purpose. The actual design of recharge well will depend on the results on strata chart and electrical log. The PVC pipe and screen of 150mm dia having 1.5mm slot width may be used against granular zones, as it has more open area for the entrance of water. |
| 34 | M&L for reaming of bore well from 150 mm dia to 300 mm dia hole below the ground level upto 40 mtrs in any kind of strata of soil / boulders / rocks etc all as specified and directed. Note : 01 Nos of bore to be done, each of depth upto 40 mtrs at different locations complete all as specified and directed. |
| 35 | Supply, assembling and lowering HDPE blind casing pipe, wall thickness not less than 10 mm, heavy grade of size 150mm dia material grade PE 80 PN 6 socketed including, fitting rivetting, jointing and lowering in bore hole, conforming to IS 12818 complete all as specified and directed. |
| 36 | All as per item No 29 here in before but slotted pipe having slots of size 1.5mm width complete all as specified and directed. |
| 37 | Supply and fixing PVC / MS bail plug assembly suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed. |
| 38 | Supply and fixing PVC/MS well cap alongwith 1\\" dia nut ball 150 mm bore suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed. |
| 39 | M&L for mild steel cross of size 200 mm x 200 mm with 150 mm branches made out of MS pipe heavy grade, having internal treads complete all as specified and directed. |
| 40 | Supply and fixing mild steel clamp, 1050mm long made out of mild steel flat of size 100 mm wide, 15 mm thick suitable for casing pipe of 150 mm dia, in two halves with suitable bolts, nuts and washers, including two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed. |
| 41 | Supply and fixing of collector pipe for recharge pit, made out of slotted MS pipe medium grade of size 150 mm dia till including collector pipe covered with PVC mesh complete all as specified and directed. |
| 42 | M&L for development of injection bore with compressed air with diesel engine operated compressor for number of houres till free flow of water in well as injected in bore complete all as specified and directed. |
| 43 | M&L for pea gravel size 2 mm aggregate free from admixture, dust clay and screened properly, complete all as specified and directed. |
| 44 | Supply and install inverter type split units indoor and outdoor complete with cordless remote control unit and with in built air filter for better indoor air quality with minimum 5 star rating single phase 240 Volts 50 HZs of 2 Ton complete with all fixing acessories.(a) Room evaporator indoor unit with speed blower fan of approipriate capacity including PCB , thremostatic control , air filter and drain for condensing water.(b) Outdoor condensing unit with condensor fan motor of appropriate capacity - 01 No. Air cooled condensor of capacity 2 TR - 01 No.Shall be installed outside the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installing of ACs.(c ) Refrigerant cooper pipe of suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit withy control valves & safety acessories invcluding complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable.(d) Making good the disturbed surface to match with the existing surface complete all as specified and directed. |
| 45 | Supply and install Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5 KVA complete all as specified and directed. |
| 46 | M&L for sub main wiring with two runs of 4 Sqmm (2x4 sqmm )1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC casing caping with all accessories fix in walls/roofs/floors etc with one run of 4 Sqmm (1x4 sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 4 Sqmm ,one run of 2.5 Sqmm ( 2x4 sqmm + 1x4 sqmm ) cable and one meter of conduit will be measured as one unit again. |
| 47 | Supply and fix of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. Please Enable Macros to View BoQ information |