| 1 | Demolition of brick work built in cement mortar or cement lime mortar including all of quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified. |
| 2 | Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed |
| 3 | Demolition of reinforcement cement concrete of any position not otherwise specifically provided complete all as specified and directed. |
| 4 | M & L brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:4 complete all as specified and as directed. |
| 5 | Ditto all as per item No 4 above but except bricks(Old size Bricks obtained from item No 1 above shall be used) |
| 6 | M & L brick work with fly ash bricks, straight or curved on plan exc 6M mean radius in half brick thick wall, old size brick built in cement mortar 1:4 complete all as specified and as directed. |
| 7 | M&L 15mm thick rendering in cement mortar (1:4) mixed with liquid water proofing compound on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed (Liquid water proofing compound shall be measured and paid separately under respective item). |
| 8 | Taking down cement plaster on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc but lime plaster any description complete all as specified and directed |
| 9 | M&L for rendering 15mm thick on other than fair faces of brick work in CM1:6,finished even and smooth without using extra cement complete all as specified and directed |
| 10 | M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed |
| 11 | M&L for cement concrete type C1 1:3:6 (20 mm graded stone aggregate) in surface channels complete all as specified and directed. |
| 12 | M & L for 40mm thick cement concrete type B-1 1:2:4 (20mm graded aggregate) as in floors,finished even & smooth using extra cement complete all as specified and directed |
| 13 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified. |
| 14 | M&L for TMT bars 10 mm dia and over for reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, and binding with and incl MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-415 or Fe-500 complete all as specified and directed. |
| 15 | M&L TMT bars of 6 to 8mm dia and over cut to lenth, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. |
| 16 | M&L for 150 mm reinforced concrete pipes, class NP2, laid and jointed complete with collars including jointing with cement joints and haunching with PCC 1:4:8 type D-2 using 40mm graded stone aggregate for 150mm bore NP2 pipe line including taking up broken sewage pipe line , all as specified and directed.Note:( Excavation and earth work shall be measured and paid separately under respective items) |
| 17 | M&L for 200 mm reinforced concrete pipes, class NP2, laid and jointed complete with collars including jointing with cement joints and haunching with PCC 1:4:8 type D-2 using 40mm graded stone aggregate for 200mm bore NP2 pipe line including taking up broken sewage pipe line , all as specified and directed. Note:( Excavation and earth work shall be measured and paid separately under respective items) |
| 18 | M&L for 300 mm reinforced concrete pipes, class NP2, laid and jointed complete with collars including jointing with cement joints and haunching with PCC 1:4:8 type D-2 using 40mm graded stone aggregate for 300mm bore NP2 pipe line including taking up broken sewage pipe line , all as specified and directed.Note:( Excavation and earth work shall be measured and paid separately under respective items) |
| 19 | M&L for providing pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for man holes and drains) including necessary form work set in CM 1:4 complete all as specified and directed.(Note :- Reinforcement shall be measured and paid separately). |
| 20 | M&L framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors; laders, framed balusters ; walk way: railings ; frame work of water tanks conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 21 | M&L for preparation of new steel and iron surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 22 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 M in depth and getting out in soft/loose soil complete all as specified and directed. |
| 23 | Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 24 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified andd directed. |
| 25 | M&L three coat of white washing newly plastered wall surfaces including preparation of surfaces complete all as specified and directed. |
| 26 | Taking down 100mm / 75mm dia AC rain water pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. (Measured over all as fixed along the centre line over the fittings and accessories) |
| 27 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall with & including existing / new PVC clamps complete all as specified and directed. |
| 28 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed. |
| 29 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall with & including existing / new PVC clamps complete all as specified and directed. |
| 30 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed. |
| 31 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed. |
| 32 | S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed. |
| 33 | S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal complete with access door with cement joint complete all as specified and directed. |
| 34 | S&F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal complete with access door with cement joint complete all as specified and directed. |
| 35 | S&F 110mm PVC (SWR) branch piece, double (double Y) equal or unequal complete with access door with cement joint complete all as specified and directed. |
| 36 | S&F 75mm PVC (SWR) branch piece, double (single Y) equal or unequal complete with access door with cement joint complete all as specified and directed. |
| 37 | S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 38 | S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 39 | M&L 75mm thick cement concrete type C2, 1:3:6 (40mm graded stone aggregate) as in sub-floors, sub-bases, etc.complete all as specified and directed. |
| 40 | S&F 60 mm thick, machine pressed rubber moulded, glossy coloured, precast conctete interlocking paver block any shape and size of M-35 grade of approved shade laid over 50mm thick sand cushion and filled with fine sand complete all as specified and directed. |
| 41 | Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed. Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed. Please Enable Macros to View BoQ information |