| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | M&L for disconnecting the electrical connections from LT panel board, taking out from sump well 40 HP electric motor pump set non clogging self priming 100x125 mm size Horizontal/ vertical type disconnecting input and output sewage connections by manual/mech arrangements, dismantling the motor and carrying to workshop for repair and carrying back the after repair, reconnecting with pump set, fixing on foundation in sump well and testing, commissioning to the entire satisfaction of Engineer-in-Charge (including taking out pumping set from sumpwell and lowiring the same after suitable repair) complete all as specified and directed. |
| 3 | All as per serial item No 2 here-in-before but 20 HP pump set non clogging self priming 100 x 125 mm size complete all as specified and directed. |
| 4 | All as per serial item No 2 here-in-before but 12.5 HP pump set non clogging self priming type (Horizontal/Vertical type) complete all as specified and directed. |
| 5 | All as per serial item No 2 here-in-before but 10 HP pump set non clogging self priming type (Horizontal/Vertical type) complete all as specified and directed. |
| 6 | All as per serial item No 2 here-in-before but 7.5 HP pump set non clogging self priming type (Horizontal/Vertical type) complete all as specified and directed. |
| 7 | All as per serial item No 2 here-in-before but 5 HP pump set non clogging self priming type (Horizontal/Vertical type) complete all as specified and directed. |
| 8 | All as per serial item No 2 here-in-before but 2 HP pump set non clogging self priming type (Horizontal/Vertical type) complete all as specified and directed. |
| 9 | M & L for rewinding the electric induction motor 3 phase 400/415 Volts 40 HP, 50 C/S by opening the same carefully removing all windings and cleaning the slots properly and rewinding the same with copper binding wire of existing guage including providing paper insulation sheets, bamboo sticks and applying two coat of varnish for proper insulation, reassembling the motor, testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge (including taking out induction motor and lowering after suitable repair) complete all as specified and directed. |
| 10 | All as per serial item No 09 here-in-before but 12.5 HP motor complete all as specified and directed. |
| 11 | All as per serial item No 09 here-in-before but 2 HP motor complete all as specified and directed. |
| 12 | M & L for rewinding the submersible electric motor 3 Phase 400/415 Volts 05 /7.5 HP 50 C/S by opening the same carefully removing all winding and cleaning the slots properly and rewinding the same with PVC insulated copper binding wire of existing guage including replacement of oil seal & water seal, refilling of oil, lubricants as per existing sizes, ressembling the motor, testing and commissiong of motor on full load to the entire satisfaction of Engr-in-Charge (including taking out and lowering in position in well of submersible Pumping set) complete all as specified and directed. |
| 13 | All as per item No. 12 hereinbefore but capacity of motor 12.5 HP (including taking out and lowering in position in well of submersible pumping set) complete all as specified and directed. |
| 14 | All as per item No.12 hereinbefore but capacity of motor 35 HP (including taking out and lowering in position in well of submersible pumping set) complete all as specified and directed. |
| 15 | Supply only for replacement ball bearing/roller bearing of existing size and make in electric induction motor, 40 HP including applying correct grade grease before replacement and cleaning the motor parts properly complete all as specified and directed. |
| 16 | All as per serial item No 15 here-in-before but 20 HP complete all as specified and directed. |
| 17 | All as per serial item No 15 here-in-before but 12.5 HP complete all as specified and directed. |
| 18 | All as per serial item No 15 here-in-before but 10 HP complete all as specified and directed. |
| 19 | All as per serial item No 15 here-in-before but 7.5 HP complete all as specified and directed. |
| 20 | All as per serial item No 15 here-in-before but 5 HP complete all as specified and directed. |
| 21 | All as per serial item No 15 here-in-before but 2 HP complete all as specified and directed. |
| 22 | Supply only for replacement cooling fan of electric induction motor 40 HP to suit the existing size of fan in replacement of fan nut bolt, keys etc complete all as specified and directed. |
| 23 | All as per serial item No 22 here-in-before but 20 HP complete all as specified and directed. |
| 24 | All as per serial item No 22 here-in-before but 12.5HP complete all as specified and directed. |
| 25 | Disconnecting the electric connection from LT Panel board, dismantling pump set non clog self priming 100 x 125 mm size horizontal/vertical type suitable for 40 HP motor complete after diconnecting input and output sewage connections by manual/mechanical arrangements and taking out pump from sump well including dismantling the pump and replacement of unserviceable part ie , steel metal bushes,bearing , nut bolts washer etch cleaning and ressembling the pump and type of machine work ie making shaft and reaming bushes etc, and transporting back the same after repair,reinstalling with motor, fixing on foundation in well and testing, commissiong to the entire satisfaction of Engr-in-Charge (including taking out and lowering in position in well of pumping set) complete all as specified and directed. |
| 26 | All as per serial item No 25 here-in-before but 20 HP complete all as specified and directed. |
| 27 | All as per serial item No 25 here-in-before but 10 to 12.5 HP complete all as specified and directed. |
| 28 | All as per serial item No 25 here-in-before but 2 to 7.5 HP complete all as specified and directed. |
| 29 | M & L for replacement of cast iron sluice valve 100 mm dia PN-1.6 as per IS-780 with brass spindle and iron wheel head including providing new nut, bolt, washers and rubber insertion sheets on both ends and taking down the existing unserviceable valves complete all as specified and directed. |
| 30 | All as per serial item No 29 here-in-before but 150 mm dia complete all as specified and directed. |
| 31 | Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 12.5 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 12.5 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and as directed. |
| 32 | Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 20 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 20 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and as directed. |
| 33 | Supply and replacement of Automatic Star Delta starter 3 phase, 415 volt for centrifugal pump set 40 HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 40.0 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and as directed. |
| 34 | Supply and replacement of DOL starter 3 phase, 415 volt for centrifugal pump set 5 HP with over load relay, magnetic coil duly fixed in enclosure having relay setting suitable for 5 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and as directed. |
| 35 | Dismantling the Monoblock/Tulu pump set 1.00 HP, single phase 230 Volt and carrying the pump to workshop for repair, replacement of required parts such as CI impeller, nut bolts, bushes, packing sheet etc.,servicing to motor, greasing etc including rebinding of the copper winding and making ready for fixing, bringing back the pump set and fixing in foundation and testing to the entire satisfaction of Engr-in-Charge and complete all as specified & directed. |
| 36 | M&L for prepration outer old surface of CI pipes of any size at STP Plant and applying two coat of synthetic enamel paint compete all as specified and as directed. |
| 37 | M&L for prepration outer and inner old surface of LT Panel of any size at STP Plant and applying two coat of synthetic enamel paint compete all as specified and as directed. |
| 38 | M&L for prepration of steel/iron surface of Areator motor with gear including gear boxes alongwith connected equipments and applying two coats of synthitic enamel paint with spray painting machine complete all as specified and as directed. |
| 39 | M&L for prepration of steel/iron/ surface of section line , discharge line, pump, motor with frame and all type of fixture i.e sluice valve, non return valve etc,at installaion no 5,6,7,11,12,13,14,& 15 (08 Nos) & STP Plant and applying one coat of synthetic enamel paint with spray paint machine including marking the direction of flow of Sewage complete installaton with colour code complete all as specified and directed. |
| 40 | Taking up/out cast iron pipe of 100 & 150 mm bore water mains (including all fittings) with spigot and socketed ends or flanged ends including burning out joints and recovering lead or dismantling flanged joints of pipes complete all as specified and directed. |
| 41 | S&F for centrifiugally cast (spun) Ductile iron pressure pipe 150 mm bore with spigot and socketed ends or flanged ends ISI stamping/marking with IS 8329/2000 classification K7 , instandard length of 5.5-6.0 m suitable for push on joint ( gasket D) with cement mortar lining in pipes complete all as specified and as directed. |
| 42 | S&F for centrifiugally cast (spun) Ductile iron pressure pipe 100 mm bore with spigot and socketed ends or flanged ends ISI stamping/marking with IS 8329/2000 classification K7 , in standard length of 5.5 - 6.0 m suitable for push on joint ( gasket D) with cement mortar lining in pipes including joint and jointing material complete all as specified and as directed |
| 43 | M&L in repair for DI fittings upto 150 mm bore flanged & spigot socketed DI pipes such as bends ,Tapers ,Tee pieces ( single & double branch ) any type ,angle/radius, straight connecting pieces etc but all ends flanged inluding jointing with jointing material complete all as specified and as directed. Note:- Excavation, earth work will be measured and paid separately in respective items of this schedule . |
| 44 | M&L for cutting existing cast iron pipe of 100 mm bore of any description for insertion of fittings and setting the pipe in proper alignment complete all as specified and directed. Note:- Excavation earth work and fittings will be measured and paid separately in respective items of this schedule . |
| 45 | M&L for cleaining of sewage wells of size 6 to 8 metre dia x 5 to 7 metre depth (approximate) at Sump well no. 2,5,6,7,10 11,12,13,14,15 and STP all wells removing soild sludge/ sewage wastage from well manually/ mechnically and disposed off out side MOD Land any means complete all as specified and directed. |
| 46 | S&F PVC extra flexible suction hose pipe 100 mm complete all as specified and directed. |
| 47 | S&F in repair of nut bolt with washer of any size complete all as specified and directed. |
| 48 | Repair/replacement of unserviceable phase preventor of existing size of motor capacity 5 HP to 40HP complete all as specified and directed. |
| 49 | M & L in repair for taking out induction motor,opening the same carefully removing all windings and cleaning the slots properly and rewinding the electric induction motor 3 phase 400/415 Volts 5 HP, 50 C/S with copper binding wire of existing guage including providing paper insulation sheets, bamboo sticks and applying two coat of varnish for proper insulation,reassembling the motor, testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge and lowering/refixing the same in original position complete all as specified and as directed. |
| 50 | M& L in repair for taking out induction motor and repairs the gear box of ariator motors by greasing ,replacement of bearing , shaft of Gear box,iron coupling and other minor /major items required to make to make it fully functional testing and commissioning of motor on full load to the entire satisfaction of Engr-in-Charge and lowering/refixing the same in original position complete all as directed by Engr-in-Charge. |
| 51 | M&L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3.5 Core laid in trenches under floors/ along/over poles et cincluding removing the existing unserviceable cable to the entire satisfaction of Engr-in-Charge.Note:- Excavation and earth work, sand cushioning, cable cover will be measured and paid separately in respective items of this schedule |
| 52 | S&F PVC Insulated & PVC sheathed Industrial cable 3 core size 10 Sq mm 415 v for Submersible motors including taking down/out exisiting unservicable cable of any size & make complete all as specified and as directed. |
| 53 | S&F in replacement PVC Insulated & PVC sheathed Industrial cable 3 core size16 Sq mm 415 v forSubmersible motors including taking down/out exisiting unservicable cable of any size & make complete all as specified and as directed. |
| 54 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of cable, pipes and for getting out to the entire satisfaction of Engr-in-Charge |
| 55 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 56 | Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed. |
| 57 | M&L for laying, spreading dry fine river sand in trenches as cushioning for ptotection of cable, 8 cm before laying of cable and 15 cm after laying of cable complete all as specified and as directed. Note:- For payment punned depth will be measured. |
| 58 | Supply and laying unreinforced precast concrete cable cover, class HVP, type-1 with peak, size 250mmx150mmx40mm laid flat adjacent and abutting to each other across the length of cable laid dry complete all as specified and as directed. |
| 59 | S&F in repair Star Delta starter MU 2 ,3 phase, 415 volt for submersible motors & pump set15HP with over load relay, contactor ML 1.5 magnetic coil duly fixed in enclosure having relay setting suitable for 15 HP pump set including taking down exisiting unservicable starter of any make & type complete all as specified and as directed. |
| 60 | M&L for laying/ fixing GI tubing 40 mm bore light grade in trenches/ floors/ alongwalls/ poles etc for passing through cables including taking out unserveciable cable complete all as specified and as directed. |
| 61 | M&L in repair for opening the air compressor and its components for repair,repair the components and replace the u/s parts if any,reassembling the Air compressor and make it fully functional, testing and commissioning to the entire satisfaction of Engr-in-Charge and complete all as specified & directed. |
| 62 | M&L in repair for opening the filteration plant and its components for repair ,replace the u/s parts if any, replace the pea gravels of size 5 to10 mm, reassembling the filteration plant and make it fully functional, testing and commissioning to the entire satisfaction of Engr-in-Charge and complete all as directed & specified. |
| 63 | S&F Lead Acid battery 12 Volts 180 AH complete all as specified and directed. |
| 64 | Supply only of calcium Hypochlorite (calcium based granular disinfectant) for water treatment, more stale than chlorine gas and stronger than bleaching powder and sodium hypochlorite) packing in 45 kg plastic drum complete all as specified and as directed. |
| 65 | Supply and mixing of poly electrolite complete all as specified and as directed. |
| 66 | Attending Day to day complaints of LT panel board of sewage pumps & motors of various capacity at pumps at different lolations,checking and maintained the of continuity of motors, If the comaplint is not rectified within stipulated time contractor will bear penality of Rs 500/- per day per complaint complete all as specified and as directed.Note :- (i) Necessary tools and plants ,ladder etc reqired will be provided by contractor .(ii) Transport reqd by the staff will be provided by contractor. Please Enable Macros to View BoQ information |