| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 4 | Brick work with common burnt clay F .P .S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with epoxy. (epoxy to be paid seprately) |
| 6 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with Epoxy etc., complete.(Epoxy to be paid sepratley) Size of Tile 1000x1000 mm |
| 7 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 8 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge Extruded section profile size 42x50 mm |
| 9 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of he shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer in-charge. (For W.C. and bathroom door shutter). |
| 10 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum Two track two panels sliding window with Aluminium channel wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approvedby Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). |
| 11 | Providing and fixing baby diaper change station complete in all respects.Build Quality- 304 stainless steel, vandal-proof body ,Load Capacity- Up to 50 kg with Adjustable straps, rounded safety edges as approved by the Engg In Charge |
| 12 | Providing and fixing hand dryer complete in all respects.Operation Type Automatic (sensor-based, touch-free),Drying Time Typically 10–15 seconds Motor Technology High-speed, energy-efficient motor Material Options Stainless steel / Steel / Impact-resistant casing,Noise Control Optimised airflow design for reduced noise Mounting Type Wall-mounted as approved by the Engg In Charge |
| 13 | Providing and fixing roll tissue dispenser complete in all respects. Material - ABS Plastic, with capacity Length of Roll- 250 – 300 Mtrs as approved by the Engg In Charge |
| 14 | Supplying and fixing Janitor Sink & spout in janitor room with concealed stop cock including cutting and making good the walls etc. at all floors and height as per instructions of EIC as a complete job. (For janitor room) |
| 15 | Supplying and fixing grab bar in disabled toilet including cutting and making good the walls. Material Stainless Steel with chrome finish. as approved by the Engg In Charge. |
| 16 | Providing and fixing 450 mm long braided hose for making wash basin connections with Nipple, 15mm Nut, O-Ring & Rubber Washer (Suitable for Basin Mixers), chrome finish and as approved by the Engg In Charge. |
| 17 | Providing and fixing mirror of superior glass (of approved quality) and cut to required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing |
| 18 | Providing, fixing, testing and commissioning cpvc pipe of grade CTS-SDR 11 conforming to IS : 15778 complete with suitable fitting, like tees, elbows, reducers, flanges, etc. male/ female threaded brass adopters, elbows, tees, pass overs, plugs etc., solvent joint as per manufacturer's recommendations, necessary painted clamp, structural support, including chasing, cutting and making good the walls, etc., complete. 15 MM DIA |
| 19 | Providing, fixing, testing and commissioning cpvc pipe of grade CTS-SDR 11 conforming to IS : 15778 complete with suitable fitting, like tees, elbows, reducers, flanges, etc. male/ female threaded brass adopters, elbows, tees, pass overs, plugs etc., solvent joint as per manufacturer's recommendations, necessary painted clamp, structural support, including chasing, cutting and making good the walls, etc., complete. 20 MM DIA |
| 20 | Providing, fixing, testing and commissioning cpvc pipe of grade CTS-SDR 11 conforming to IS : 15778 complete with suitable fitting, like tees, elbows, reducers, flanges, etc. male/ female threaded brass adopters, elbows, tees, pass overs, plugs etc., solvent joint as per manufacturer's recommendations, necessary painted clamp, structural support, including chasing, cutting and making good the walls, etc., complete. 25 MM DIA |
| 21 | Providing, fixing testing and commissioning full bore brass ball valve suitable for 10 kg/sqcm working pressure with lever and female screwed ends, of approved quality. 15 mm dia |
| 22 | Providing, fixing testing and commissioning full bore brass ball valve suitable for 10 kg/sqcm working pressure with lever and female screwed ends, of approved quality. 20 mm dia |
| 23 | Providing, fixing testing and commissioning full bore brass ball valve suitable for 10 kg/sqcm working pressure with lever and female screwed ends, of approved quality. 25 mm dia |
| 24 | Supply and fix Unplasticised PVC pipes of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.32 mm dia |
| 25 | Providing, Fixing, Testing & Commissioning of uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) 110 mm dia |
| 26 | Providing, Fixing, Testing & Commissioning of uPVC SWR pipes (Type-A) confirming to IS 13592 along with all required fittings like tees, bends, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings with clamps complete including angle supports and cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Rain water pipe) 110 mm dia |
| 27 | Supply, installation , testing & commissioning in position SWR PVC P trap of self cleaning design of following sizes. Making proper connection with Cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as per specifications including cost of cutting and making good the walls and floors after installation of P traps wherever required. 110 mmx110mm |
| 28 | Supply, installation, testing & commissioning 100mmx63mm PVC waste reducing elbow including cutting chases, making holes in the floor/ slab, restoring the same after installation complete as per approved specifications and connection to pvc pipe |
| 29 | Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket including socketed joint complete as per approved specifications For 110 mm dia pipe |
| 30 | Providing and fixing 125 mm dia, 1 mm thick stainless steel grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete. |
| 31 | Providing and fixing Toilet cubical(of following standard dimension which includes 600mm door size width) made up of thermosetting resign treated high pressure ,self supporting decorative compact laminates with permanently incorporate anti-bacterial agents(under JIS Z2801:2000 certification) during manufacturing .Compact board should be resistance to water immersion through permissible increase on thickness and mass <0.60% and board density >1.35kg/cm3 and fulfilled the criteria of green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/97 and EN438-6 with classification of BS1D0 standard. Pilaster to be supported with SS(grade316) adjustable foot and intermediate panels will attached to the wall with the help of approved SS(grade316) channels and all required hardware, made up of stainless steel as per manufacturer’s specification.. Door knob, gravity hinges,Thumb turn locksets with occupancy indicators ,coat hooks with door stoper , U channel, top rail with corner connector, adjustable foot/pedestal,Rubber noice deafening tape, screw & wall plugs should be approved under the instruction of Engineer-in-charge. The top fitting should consist of SS round top rail which will get fixed with pilaster, with SS panel tube holder ,SS corner bend (connected with top rail ) will be use in corner of cubical in absence of brick wall, SS wall fixing is used only on the wall which will hold the SS top rail. All screw will of 304 grade in SS with stain finish. All pilasters are supported by SS bottom cladding . The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150 mm.Finish and colour of Toilet cubical should be approved under guidance of engineer-in-charge. Toilet cubical with standard dimension of 2025mm(H)x1000mm(W)x1500mm(Depth), which includes 600mm door size width or as per drawing.('L') ,Toilet cubical I- shape(front partition)with standard dimension of 2025mm(H)x1000mm (W) which includes door size width or as per drawing.('I'), All aspect specified by the manufacturers , Greenlam sturdo Classique Evergreen model / Merino Restrooms/Century Cubicles (CenturyPly) or equivalent. |
| 32 | 12mm Cement plaster in cement mortar 1:6 (1 cement : 6 sand) in single coat on the fair/Rough side of brick/ concrete/ stone walls for plastering upto all floor level including arrises,internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. |
| 33 | 15mm Cement plaster in cement mortar 1:6 (1 cement : 6 sand) in single coat on the fair/rough side of brick/ concrete/ stone walls for plastering upto all floor level including arrises,internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. |
| 34 | Providing and plastering, 6mm Cement plaster to ceiling In Cement mortar 1:3 (1 Cement:3 Sand) including carraige of materials with all leads and lifts as per Engineer-In- Charge. |
| 35 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOCcontent less than 50 gram/litre. |
| 36 | Finishing walls with Premium Acrylic Smooth exterior paintwith Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 39 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers |
| 40 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 41 | Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 42 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 43 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 300 mm diameter |
| 44 | Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 45 | The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 46 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 47 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C Makes:- (KEI/Anchor/Plaza , JAGUAR/Legrand(Myrius)/Schneider(Livia) |
| 48 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Makes:- KEI/Anchor/Plaza 2x1.5 Sq. mm. |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Makes:- KEI/Anchor/Plaza 2x4 Sq. mm. |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Makes:- KEI/Anchor/Plaza 2x10sq.mm |
| 51 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5 Sq. mm. Make:- KEI/Anchor/Plaza |
| 52 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- Anchor/L&T/Schneider. Single pole. 6-32 Amp. Cat-A. |
| 53 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- Anchor/L&T/Schneider. Double pole 63 Amp. Cat-A. |
| 54 | Supplying and fixing following rating & pole, 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- Anchor/L&T/Schneider. Double pole 63 Amp. Cat-A. |
| 55 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Makes:- Anchor/L&T/Schneider. Double door-12 way |
| 56 | Providing and Fixing of IP40 LED fixture of 15 watt +/- 1 W LED recess Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 4000 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Makes: WIPRO/JAQUAR/PANASONIC |
| 57 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: |
| 58 | Supplying and fixing following modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make: Jaquar/Legrand(Myrius) |
| 59 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredMake: Jaquar/Legrand(Myrius) |
| 60 | Providing and Fixing of LED profile light suspended/surface mounted unique tappered profile product high on esthetics and performance housing with micro texture powder coating 12 watt with minimum system lumen efficacy of 100 lm/W with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 4000 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 61 | Supplying and fixing following size/modules,G.I box alongwith modular base & cover for modular switches in recess etc.as required |
| 62 | GI Chemical earthing / grounding protection system for Electrical system including GI wire 8 swg as required complete in all respect. |
| 63 | Providing & fixing E sence group light sensor 10amp recess smart PIR occupancy detector with switching photo cell with analog output as required complete in all respect. list price wipro 2022 as per cat no. GLPSAN01IR010A |
| 64 | Providing and preparing a complete set of \\"Good for Construction\\" (GFC) Architectural and Interior Design Drawings for the toilet block, including the development of a detailed Window & Door Schedule, Sanitary & Plumbing Interior Details, and a coordinated Lighting Plan,etc, provided in both Hard Copy and CAD/PDF formats as directed by Engg In Charge. Please Enable Macros to View BoQ information |