| 1 | Excavation in foundations in Ordinary Soil (Loam Clay or sand) including lift upto 1.5m. (5 fts.) and lead upto 30 m. (100 fts.) & including filling, watering and ramming of excavated Earth into the trenches or into the Space between the building and sides of foundation trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-incharges upto a distance of 30m. (100fts.) from the foundation trenches. (Rate including Royalty of earth also.) |
| 2 | Earth work in cutting or in embankment in ordinary soil excavation to be in the from of regular pits not exceeding 0.50M. in depth and earth work in embankemnt to be in 20cm. layers including remmeing and dressing the surface to required levels and slopes and also including 1.50M lift and 30M. lead. The earth from cutting to be used in making embankment or to be deposited as spoil banks with in 30M. distances as directed by the Engineer incharge. Excluding Royality. SI. 253(a) |
| 3 | Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered Depth exceeding 3m but not exceeding 4.5 m |
| 4 | Extra for every additional lift of 1.5 m or part thereof in : Ali kinds of soil |
| 5 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. |
| 6 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 7 | Cement Concrete with 2cm guage approved stone ballast, coarse sand & cement in the proportion of 4:2:1 in foundation and under floor including supply of all materials , labour , T&P etc. required for proper completion of the work. |
| 8 | Cement Concrete with 4cm guage approved stone ballast, coarse sand & cement in the proportion of 8:4:1 in foundation and under floor including supply of all materials , labour , T&P etc. required for proper completion of the work. |
| 9 | Providing and laying in position specified grade of Reinforced Cement Concrete excluding the cost of shuttering, finishing and reinforcement - all work upto plinth level |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone III) :3 graded stone aggregate 20 mm nominal size) Excluding Royality |
| 11 | Reinforced Cement Concrete works in walls, (any thickness) excluding the cost of shuttering, finishing and reinforcement |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone III) :3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced Cement Concrete works in Beams, suspended floors, excluding the cost of shuttering, finishing and reinforcement |
| 14 | Centering and shuttering including strutting, propping etc and removal of form for all heights |
| 15 | Foundations, footings, bases of columns etc. for mass concrete |
| 16 | Walls (any thickness ) incl. attached pilasters, butteresses, plinth and string course etc |
| 17 | Suspended floors, roots, landings, balcnies and access platform |
| 18 | Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 19 | Steel Reinforcement for RCC work including Straightening, sutting, bending, placing in position and binding all complete upto plinth level |
| 20 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 21 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). |
| 22 | All works upto plinth level |
| 23 | All works above plinth level upto floor V level |
| 24 | First Class - 150 brick work in 1:6 cement and Coarse sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour and tools and plants etc.required for proper completion of the work. |
| 25 | As in item (303) above, but in 1:4 cement and Coarse sand mortar. |
| 26 | As in item (309) above, but for wall of one brick thick add for extra labour. |
| 27 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer. |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 29 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer- in charge. |
| 30 | Cement concrete flooring with metallicstone agregate) finished with a floating coat of neat cementincluding cement slurry, etc. but excluding the cost of nosing ofsteps etc. complete. |
| 31 | 12 mm cement plaster of mix : |
| 32 | 1:4 (1 cement : 4 coarse sand) |
| 33 | Neat cement punning |
| 34 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 35 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 36 | Finishing walls with premium acrylic smooth exterior paint with required shade : New work (Two or more coat applied @1.43lit/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 37 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 38 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 39 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality : H D - 20 : Circular shape 560 mm internal diameter |
| 40 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 41 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per complete as per clause 401G-III, MORTH CI-401,Table 400 |
| 42 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory rolle to achieve the desired density, as per MoRT&H specification clause No. 406JMF Shall be got design form any reputed from |
| 43 | Providing and applying tack coat with SS 1 grade bitumen emulsion on prepared surface of granular sub base including cleaning of surface and spraying primer. |
| 44 | On W.M.M. @ 0.70 kg./sqm. |
| 45 | Providing and applying tack coat with bitumen grade VG-10 using emulsion pressure distributor at the rate of 0.25 kg/Sqm on prepared bituminous surface cleaned with mechanical broom |
| 46 | Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG - 30 @ 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H specification clause No. 505 complete in all respects. |
| 47 | 50mm average compacted thickness. |
| 48 | Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder CRMB 55 @ 5.4 Percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects. |
| 49 | 30mm compacted thickness |
| 50 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 51 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer - in- charge. |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 54 | Made of G.I. wire of dia 4 mm |
| 55 | NON- SCHEDULE ITEMS |
| 56 | Supply and fixing almumnium goal post of FIH approved drawing and design incl. all fittings and net |
| 57 | Providing and installation of SS Grade 304 water trays with water out let, around the turf at entrance gate and all carriage complete job |
| 58 | Supply, installation and commissioning of Wireless ztiming Gates by SmarTracks In-Ground System comprising high-quality magnetic sensors embedded at recomended positions along the hockey turf. Including SmarTracks Mobile System with 8 timing gates, 4 diagnostic sensors, and PC-based analysis software for athlete performance assessment, manage and improve players’ performance. |
| 59 | Supplying FIH approved global category Synthetic Hockey Surface with polyethylene fiber and cast in situ shock pad layimg jointing and ixing the same on the bituminous sub base with rubberized under layer as per the FIH requirements and the pasting of synthetic grass as per specification of the global category FIH competition including all marking on the surface as per FIH rules and standard etc. complete as per the instructions of the Engineer-in-charge. # stitches / lm 340 / lm Pile Height 12 mm, Pile Weight 1.500 gr / m² ( tolerance +-10%) total height 14 mm. |
| 60 | PART-B ELECTRICAL WORKS |
| 61 | Supply, Installation, testing and commissioning of Integral LED flood light of with system wattage of 820W (±10W) (@full load) made of Single piece Aluminium pressure die cast housing (The luminaire shall employ all the LED compartments within in one single piece housing and the product should not be an amalgamation of multiple luminaires joined together mechanically.), recyclable non corrosive, resistance to mechanical strength and vibration caused by winds must have gone through the 500hrs marine salt test protection powder coating. Luminaire and Driver should be on same make in order to maintain the compatibility. Solution comprising of multiple lower wattage Luminaire mounted/clubbed together shall not be accepted. Ingress protection must be with a silicon gasket, glue free, against water ingress to endure higher endurability. Nominal voltage range of 220V-240V having system lumen output at Ta=35°c of =105000lm to meet the desired lux level as per the tender requirement having Luminaire system efficacy of ≥125Lumen/watt and Driver efficiency at =85%, providing CRI=70, CCT 5700°K, THD =20%, SDCM =5. The same luminaire shall be available with minimum 7 different beam angles including variants in asymmetric beam angle. |
| 62 | The luminaire shall be suitable for working in ambient temp of -10 to plus 55 degree centigrade (IEC60598). The luminaire must be having Class 1 Electrical insulation, IP66 ingress and IK08 impact protection, Power factor =.95 at full load. Fixture must have life class of 50000 burning hour as per L70B50 at Ta 35c. The nominal Luminaire weight must be between 27KG (±5%), LED make used in the product should be from Signify (Philips), Nichia, Osram. LEDs used shall only be High Power ceramic based single chip 3V LED with silicone dome and typical wattage of LED chip 3W Max, LED efficacy =150Lm/W at If= 700 mA: TJ = 85 °C. Fixture must comply to below standards for different mentioned parameters IEC61347-1 (Driver safety), LED Drivers should have High voltage protection, 440V protection for 8 hr and shall have in-built surge protection of 4KV. The driver shall be potted using Ashphalt / combination of Ashphalt and silicon, EMI/EMC compliant as per IEC-61547. |
| 63 | The luminaire should have 10KV/5KA SPD, should be able to sustain minimum 15 hits of 5KA rating that is total of 45 hits across all the three modes as per IEEE62.41.2. The luminaire driver and It’s SPD shall be of the same make/manufacturer/lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 Standard, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire and Driver. Similar to above Specs in Signify (Philips/Ecolink), Regent/Endo/Abacus/LigmanBajaj, Crompton, wipro, Polycab, Havells, Everady |
| 64 | CablesSupplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Polycab, RR Cable, Finolex, Havells. |
| 65 | 3 x 2.5 sq. mm |
| 66 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Nicco, RPG, Universal, Havells, Polycab, fort Gloster, Diamond |
| 67 | 25 sq. mm 3-1/2 core |
| 68 | 70 sq. mm 3-1/2 core |
| 69 | Conduit |
| 70 | SITC of 25 MM MS flexibale conduit (Polypack, AKG, BEC, Precision) |
| 71 | Supply and making end termination with brass comprassion gland and aluminium lugs for following size of pvc insulated and pvc sheathed / XLPE Aluminium /copper conductor cable of 1.1 Kvgraded |
| 72 | 3CX 2.5sqmm unarmoured CU cable |
| 73 | 3CX 25sqmm Armoured AL cable |
| 74 | 3.5CX 70sqmm armoured AL cable |
| 75 | Earthing |
| 76 | Supply and lying of Chemical/Maintenance free Earthing with complete accessories with 3 meter chemical long40-50mm dia copper electrode with 50 kg chemical compound and earthing fullfil IS3043 for 1 OHM below resistance. |
| 77 | Providing and fixing 25 mm X 5 mm G.I. strip 0n surface or in recess for connection etc. as required. |
| 78 | High Mast Fixed Type |
| 79 | Supply, Installation, testing & commissioning of 35m Hot dip galvanised, polygonal high masts with fixed head frame/cross arms suitable for mounting up to 19No's of LED Flood Light complete with all accessories as per specification. The lights shall be mounted on top surface of each crossarm only. Hanging type mounting of LED lights is to be avoided The height of the mast from base to TOP of head frame shall be 35mtrs. Polygonal high mast tower with fixed head frame along with provision for using man rider (speed should be approx 4m/Min) for accessing the head frame platform. Structural design of the high mast should be carried out as per the technical report no.7/ relevant standard and regulation. The mast should be designed considering base gust wind speed of 47m/s or as per IS 875 and thickness of GI coating should withstand at the speed of 47m/s. Price shall include suitable 1.2m Lightning Arrestor as per requirement and 2 nos of LED Aviation Light. Similar to above specifications in Signify (Ecolink) /Valmont/Ligman/Vakrangee/RR Ispat. Philips, Bajaj, B.P Projects, Crompton. (including civil work ) |
| 80 | Manrider |
| 81 | The Mast should have comprehensive arrangement of motorised climbing mechanism (man rider) cage unit for accessing the head frame for repair / maintenance purpose with all safety arrangement like free fall arrester / overload protection etc.The mobile man rider unit which shall be common to all four masts with a minimum safe load carrying capacity of 300Kgs and sufficient space for carrying two persons with tools and at least one LED Light.The operational requirements are as follows:Climbing speed: 4 Meters / Minute (minimum)Voltage rating: 3-phase, 400V, 50Hz AC Motor Capacity: 300kgs minimum |
| 82 | Feeder Piller high mast |
| 83 | Supplying, installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 3mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below.(L&T, Siemens, Tricolite, C&S. ABB, Ischineider, Crompton.) |
| 84 | Incomer (all MCCCB&MCB should be cat-C(AAA)) |
| 85 | 1 No. 63A, TPN MCCB (15kA) with thermo magnetic releases and all required accessories. |
| 86 | 1 Set phase indication lights (R, Y, B) Solid state type (LED) |
| 87 | 1 No. 0 to 500V, AC, Volt Meter with VSS & control fuses. |
| 88 | 1 No. 0 to 100A, Ammeter with ASS &CT's. of ratio 100/5A and class-1 accuracy. |
| 89 | Auto Manual Switch |
| 90 | BUS BARS:- |
| 91 | 100A 4 wire 3 phase 35KA Aluminium bus bars |
| 92 | OUT GOINGS:- |
| 93 | 1 Nos 32A Four Ploe MCB for Man Rider. |
| 94 | 2 nos. + 1 Spare 10A SPN MCB - for Aviation Light |
| 95 | 19 nos. +2 Spare 10A SPN MCB - for Light fixture |
| 96 | Main Panel |
| 97 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.(L&T, Siemens, Tricolite, C&S, ABB, Ischineider, Crompton. |
| 98 | Incoming(all MCCCB&MCB should be cat-C(AAA) |
| 99 | 200 Amp. MCCB-1 No |
| 100 | Outgoing |
| 101 | 100 Amp. MCCB-1 No & 63 Amp. MCCB-3 Nos. |
| 102 | SITC OF 125 KVA, 11/0.433KV TRANSFORMER (OIL TYPE) |
| 103 | Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge.BHEL, Crompton, ABB, Voit, AMP |
| 104 | 100KVA DG Set Equipment With AMF Panel |
| 105 | Providing, Installing, Testing and Commissioning of 100 KVA ‘Silent Type’ Diesel Generating set along with having Prime Power Rating, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings including making necessary civil foundation etc. complete as required:Jakson, Cummins, Kirloskar, Greaves Power. |
| 106 | Supply of MV cable |
| 107 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 108 | 70 sq. mm 3-1/2 core |
| 109 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 110 | 3½ X 70 sq. mm (38mm) |
| 111 | Providing and laying of DWC - SN8 (IS:16098-II) pipes : 300 mm dia, Pipe in under ground system for provision in electrical line and sprinkler lines leeve purposes and drainage outlet complete in all respect as per direction of engineer in charge. |
| 112 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |