| 1 | SH: I (Routine Maintenance, Operation of DG set and attending complaints)Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying staffs as per details and terms & conditions attached etc. as required for CEO office, Kashmere Gate and Running maintenance & operation, general upkeep, preventive maintenance including minor repair works, as and when required and recording reading in log book for 400 KVA Compact type electrical substation comprising of transformer, HT/LT Panel, ACB, MCCB & allied accessories & keeping the entire installation on functional mode including D.G. set comprising of A.M.F. Panel& allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works by deploying staffs (wireman/E&M Operator- 3 Nos. round the clock, Khallasi - 1 No. general shift on all working day including Sunday and holiday) as per details and terms & conditions attached etc. as required. CEO office, Kashmere Gate. (wireman/E&M Operator- 1 Nos. round the clock, Khallasi - 1 Nos. general shift on all working day including Sunday and holiday). (for 1 Nos. Wireman = 36460 x 3= 109380 & 1 No. Khallasi = 1x 30186 = 30186) i) 160 KVA DG Set (Kirloskar make) -1 No.ii) 82.5 KVA DG Set (Kirloskar make) -1 No.iii) 62.5 KVA DG Set (Kirloskar make) -1 Nos.iv) 400 KVA Compact Sub Station -1 Nos. |
| 2 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying staffs as per details and terms & conditions attached etc. as required for CPO Building (Sindhi & Urdu Academy), Sub Registrar office, NCC Boys and Girls, Naval Battalian and Civil Sub division-III (SRD-I), Kashmere Gate. and Running maintenance & operation, general upkeep, preventive maintenance including minor repair works, as and when required and recording reading in log book for D.G. set comprising of A.M.F. Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works by deploying staffs as per details and terms & conditions attached etc. as required. CPO building (Sindhi and Urdu Academy) office, Kashmere Gate. (wireman/DG Operator- 1 No. general Shift on all working day Excluding Sunday and holiday and Khallasi - 1 Nos. general shift on all working day Excluding Sunday and holiday). (for 1 Nos. Wireman/DG Operator = 31287 x 1= 31287 & 1 No. Khallasi = 1x 25921 = 25921) |
| 3 | SH:II (DG Set)Annual Preventive & Comprehensive/Periodical Maintenance Of following Kirloskar make D.G. Sets installed at following locations (CEO office, CPO Building) alongwith engine, alternator, AMF panel, including batteries, pipeline and other associated accessories etc. complete with routine testing etc. as reqired and attending all major/minor faults or failure or complaint complete in all respect & providing at least one Electrical & Mechanical visit in a month as required, as per terms & condition attached and as per direction of Engineer-In-Chargea) 160 KVA DG Set (Kirloskar make) -1 No. |
| 4 | b) 82.5 KVA DG Set (Kirloskar make) -1 No. |
| 5 | c) 62.5 KVA DG Set (Kirloskar make) (CEO & CPO) -2 Nos. |
| 6 | Carrying out of B-Check/Servicing of following DG set on every six month including providing and fixing of items as per T&C etc complete as required.a) 160 KVA DG Set (Kirloskar make) -1 No. |
| 7 | b) 82.5 KVA DG Set (Kirloskar make) -1 No. |
| 8 | c) 62.5 KVA DG Set (Kirloskar make) (CEO) -2 Nos. |
| 9 | SH: II (EI Work)1 ) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.01) Group C |
| 10 | 2) Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2.01) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | 2.02) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 12 | 2.03) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | 3) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.3.01) Group C |
| 14 | 4) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4.01) 3 x 1.5 sq. mm |
| 15 | 4.02) 3 x 4 sq. mm |
| 16 | 4.03) 3 x 6 sq. mm |
| 17 | 5) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.5.01) 20 mm |
| 18 | 5.02 ) 25 mm |
| 19 | 6) Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6.01 ) 3 Module (100mmX75mm) |
| 20 | 6.02) 6 Module (200mmX75mm) |
| 21 | 6.03) 8 Module (125mmX125mm) |
| 22 | 6.04) 12 Module (200mmX150mm) |
| 23 | 7) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.7.01) 5/6 amps switch |
| 24 | 7.02) 15/16 amp switch |
| 25 | 7.03) 3 pin5/6 amp socket outlet |
| 26 | 7.04) 6 pin15/16 amp socket outlet |
| 27 | 8 ) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 28 | 9 ) Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 29 | 10) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 30 | 11) Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 31 | 12) Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 32 | 13) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.)13.01) 8 way (4 + 24) |
| 33 | 14) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator)14.01) 6 way |
| 34 | 14.02) 8 way |
| 35 | 15 ) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.15.01) Single pole |
| 36 | 15.0) 2 Double pole |
| 37 | 15.03) Triple pole |
| 38 | 16) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.16.01 ) 63 amps |
| 39 | 17 ) Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.17.01) 100 amps |
| 40 | 18) Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.18.01) For 8 way, Double door TPN MCBDB |
| 41 | 19) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 42 | 20) Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 43 | 21) Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 44 | 22) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 45 | 23) Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 46 | 24) Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 47 | 25) LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)25.01) 36 watt |
| 48 | 26) LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim26.01) a) 12 -15 watt |
| 49 | 27) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)27.01) 18-22 watt |
| 50 | 28) Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.28.01) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 51 | 29) Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.29.01 ) 100 mm width X 50 mm depth X 1.6 mm thickness |
| 52 | 30) Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.30.01) 100 mm width X 50 mm depth X 1.6 mm thickness |
| 53 | 31) Supplying, Installation, Testing and Commissioning of following capacity Capacitor in the existing ceiling fan etc. Complete as required.31.01) 2.5 Mfd Capacitor |
| 54 | 31.02) 4 Mfd Capacitor |
| 55 | 32 ) Supplying, installation, testing & commissioning of 450mm sweep size metal body Oscillating type wall fan of with fan regulator and fixing with the help of dash fasteners including connections etc as required. |
| 56 | 33) Supplying, Installation, Testing and Commissioning of following size 1400 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.33.01) 300 mm sweep |
| 57 | 34) Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd. |
| 58 | 35) Supplying and fixing of PVC cable management system / wall trunking with cover of following sizes including internal, external, flat single cover and T- cover , end cap and other accessories on the wall so as to make complete etc as required. 35.01) 100 mm x 50mm |
| 59 | 35.02 ) 50 mm X 50mm |
| 60 | 36 ) Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on Wall/surface etc complete as required.36.01) a) 3 X 10 Sq.mm |
| 61 | 36.02) b) 3 X 16 Sq.mm |
| 62 | 36.03) c) 4 X 25 Sq.mm |
| 63 | 36.04) d) 3.5 X 35 Sq.mm |
| 64 | 36.05) e) 3.5 X 50 Sq.mm |
| 65 | 37) Refilling of the fire extinguishers of following capacity Co2 type fire extinguisher as required.a) 4.5 Kg |
| 66 | 38) Refilling of ABC type fire extinguisher following capacity carring to work shop and after refilling reinstallation at same site.a) 6 Kg |
| 67 | 38.01) b) 50 kg |
| 68 | 39) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 200 watt |
| 69 | 40 ) Less credit of following electrical accessories etc. complete as required.40.01) (a) Assorted copper wire/cable/pipe |
| 70 | 40.02 ) (b) Scrap iron/ conduit/ box |
| 71 | 40.03) (c) DBs (assorted size) |
| 72 | 40.04 ) (d) MCBs (assorted size) |
| 73 | 40.05) (e) MCCBs (assorted size) |
| 74 | 40.06) (f) Switch/Socket (assorted size) |
| 75 | 40.07) (g) Ceiling Fans assorted size |
| 76 | 40.08) (h) Wall Fan (assorted size) |
| 77 | 40.09) (i) Exhaust Fan (assorted size) |
| 78 | 40.10) (j) Fresh Air Fan (assorted size) |
| 79 | 40.11) (k) Batten Lights (assorted size) |
| 80 | 40.12) (l) Downlights (assorted size) |
| 81 | 40.13) (m) Flood Lights (assorted size) |
| 82 | 40.14) (o) Assorted XLPE aluminium cable Please Enable Macros to View BoQ information |