| 1 | Earthwork excavation for foundation by manual means for Isolated,Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering,bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2.00mts and clearing and levelling the site etc., complete complying with standard specification and as directed by the departmental officers. |
| 2 | Supplying and filling in foundation,basement etc with filling crushed stone sand in layers of not more than 15cm thick well watered,rammed and consolidated etc complete complying with standard specification and as directed by the departmental officers. |
| 3 | Cement Concrete 1:5:10 (One Cement,Five crushed stone sand and Ten hard brocken stone jelly) using 40mm gauge hard brocken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15cm thick well rammed,consolidated and including curing etc complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 4 | Brickwork in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer,curing,etc complete complying with standard specification and as directed by the departmental officers.Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 5 | Basement |
| 6 | Gournd Floor |
| 7 | Supplying and erecting steel centering including necessary supports for plane surfaces such as rectangular or square RCC columns etc which require only nominal strutting using mild steel sheets made of 10gauge thick welded with MS angle size 40x40x5mm and supported by Steel Adjustable Telescopic Props of Size 2x2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) etc complete in all floors complying with standard specifcation.Steel Adjustable telescopic props shall be provided as directed by the departmental Officers.(Payment for centering shall be given after the concrete is laid). |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings,column pedestals,plinth beams, grade beams,staircase steps,Sill slabs etc which require only nominal strutting using mild steel sheets of size 90x60cm and 10BG stiffened with welded mild steel angles of size 25x25x3 mm for boarding,laid with silver oak joists of size 10x5cm & 7.5x5cm as support runner, vertical stiffener,side support and Top Horizontal stiffener spaced at about 60 to 90cm centre to centre or at suitable intervals etc complete in all floors complying with standard specifcation.(Payment for centering shall be given after the concrete is laid). |
| 9 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500,Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) a) Below Plinth /Basement level |
| 10 | Cement Concrete 1:1-1/2:3 (One Cement,One and a half crushed stone sand and Three hard brocken stone jelly) using 20mm gauge hard brocken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser,mixing charges for machine mix,laying,vibrating with mechanical vibrators,finishing,curing,etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary and bearing surfaces of walls,beams etc shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra,etc complete complying with standard specification and as directed by the departmental officers - machine mix |
| 11 | Basement |
| 12 | Supplying and fixing Mild Steel grills for windows,ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 13 | Providing Chain link fencing 2\\"x2\\" using 10 gauge Galvanised iron wire with necessary binding wire for tying post including cost of all materials and labour charges etc.complete |
| 14 | Supplying,laying and jointing GI Pipes of approved quality and best variety of “B” class pipe of the following dia including labour fixing GI Specials,(excluding charges for cutting and threading of pipes,cost of such specials) to wall with necessary teak wood plugs,clamps,screws,thread balls,shellac,etc making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessary brick work/concrete and plastering wherever necessary with necessary scaffolding charges.The pipes are to be painted with the 2coats of good variety and approved best quality of synthetic enamel paint over a priming coat of red oxide etc complete in all floors complying with standard specification GI pipes shall be got approved by the Executive Engineer before use on works-Internal water supply-Above Ground Level/External water supply-Above Ground Level |
| 15 | 32mm dia GI pipe for Fencing pole |
| 16 | Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and MS angles of size 35x35x5mm for the shutter frames,stiffeners with 32x6mm MS flat is provided at required intervals in the shutter frame.18-gauge CR sheet laid as panel in the shutter and welded intact MS flat 18x5mm is welded over the 32x6mm MS flat sandwitching the CR sheet in between additional stiffeners with 18x5mm MS flat is provided diagonally at the rear side of the shutter.3nos of Steel Parliament Hinges of Size 12x150mm in case of single leaf and 6nos of Steel Parliament Hinges of Size 125x150mm in double leaves shutter to be provided 6nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frames of the door.Tower bolts 3nos,one at the top,one at lock rail(Inner) and the other at the bottom are provided 1no.Aldrop is provided at lock rail section in the door 2Nos of 200mm handle are to be provided.One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.Incase of double leaf door MS Flat 32x3mm at 1.1Kg/m is provided on the one shutter conceal the gap between the two shutters at an appropriate place in the door.A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing.All members are given a coat of red oxide primer as directed by the departmental officers.The rate includes cost of all materials,labour charges,transportation to site of work,loading,unloading and all other incidental charges etc complete complying with standard specification and as directed by the departmental officers.-Single leaf of size-1.00x2.10m. |
| 17 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand),12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used curing etc complete complying with standard specification and as directed by the departmental Officers. |
| 18 | Supplying and laying of Interlocking Paver Block Stone 60mm thick Over a base layer of crushed stone sandfilling including Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers. |
| 19 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc complete complying with standard specification and as directed by the departmental officers.(The make,quality and colour of paint should be got approved by the Executive Engineer before use on works) |
| 20 | Cement Concrete 1:2:4 (One Cement,Two crushed stone sand and Four hard brocken stone jelly) using 20mm gauge hard brocken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges,centering and shuttering but including Super Plasticiser,mixing charges for machine mix,laying,vibrating with mechanical vibrators,finishing,curing,etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary and bearing surfaces of walls, beams etc shall be finished smooth with Cement Mortar 1:3(One Cement and Three M Sand) and kraft paper laid over it without claiming extra,etc complete complying with standard specification and as directed by the departmental officers -machine mix |
| 21 | Providing and fixing of Retro-Reflectorised board size 4.80x1.20m made of high intensity grade sheeting vide clause 801.3 fixed over ACP sheet 2mm thick with 25x25x6mm stainless steel pipe (304 grade) and 33.40mm stainless steel pipe (304 grade) outer frame around with horizontal centre strut supported on 73mm dia stainless steel pipe firmly fixed to the ground by means of properly designed foundation with M15 grade concrete 45x45x75cm below ground level etc complete Please Enable Macros to View BoQ information |