| 1 | Item Description |
| 2 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. MPPWD USOR ITEM NO 2.1 P.No. 12 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil MPPWD USOR ITEM NO 2.6 P.No. 13 |
| 4 | Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. MPPWD USOR ITEM NO 2.27.2 P.No. 20 |
| 5 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. MPPWD USOR ITEM NO 2.24 P.No. 19 |
| 6 | C.C. upto plinth level With 20mm metal M-15 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level With 20mm nominal size graded stone aggregate. M-15 – Grade concrete MPPWD USOR ITEM NO 4.1.1.3 P.No. 40 |
| 7 | Centering and shuttering Upto plinth Upto plinth: Centering and shuttering Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. MPPWD USOR ITEM NO 4.3.1 P.No. 41 |
| 8 | RCC upto plinth M20 Providing and laying in position specified grade of reinforced cement concrete (nominal / design mix with 20mm nominal size graded stone aggregate) excluding the cost of centering,shuttering, finishing and reinforcement -All work up to plinth level : M-20 Grade Concrete MPPWD USOR ITEM NO 5.1.1 P.No. 78 |
| 9 | RCC in walls, columns, pillars etc Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete MPPWD USOR ITEM NO 5.2.1 P.No. 78 |
| 10 | RCC in beams, floors, staircases etc Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. M-20 Grade Concrete MPPWD USOR ITEM NO 5.3.1 P.No. 78 |
| 11 | Centering and Shuttering upto plinth level Foundations, footings, bases of columns, etc. for concrete upto plinth level MPPWD USOR ITEM NO 5.9.1 P.No. 79 |
| 12 | Centering and Shuttering above plinth level Above plinth upto 3.6 m height from plinth level MPPWD USOR ITEM NO 5.9.2.2 P.No. 79 |
| 13 | Centering and Shuttering Columns Columns, P i l l a rs , Piers, Abutments, Posts and Struts. MPPWD USOR ITEM NO 5.9.6 P.No. 80 |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Mild and medium Mild steel and Medium Tensile steel bars. 1% of All R.C.C. Work =6.57 cum x 1% x 7850 kg/cum =516.37 kg say 560 kg MPPWD USOR ITEM NO 5.16.1 P.No. 82 |
| 15 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etccomplete. Cement Mortar 1:6 (1 cement: 6 sand). MPPWD USOR ITEM NO 6.5.2 P.No. 114 |
| 16 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete.Cement Mortar 1:6 (1 cement: 6sand). MPPWD USOR ITEM NO 6.6.2 P.No. 114 |
| 17 | Structural steel work built up sections Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. size of Main Gate is 2.5meter x 1.80meter and it's Quantity Lum Sum Approximately 175kg. MPPWD USOR ITEM NO 10.2 P.No. 303 |
| 18 | M.S. sheet door and angle iron frame With angles braces Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessaryfittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6mm for diagonal braces MPPWD USOR ITEM NO 10.5.1 P.No. 303 |
| 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix1:6 (1 cement : 6 sand) MPPWD USOR ITEM NO 13.2.2 P.No. 468 |
| 20 | White washing with lime to give an even shade: New work (three or more coats) MPPWD USOR ITEM NO 13.43 P.No. 474 |
| 21 | Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. MPPWD USOR ITEM NO 13.44 P.No. 474 |
| 22 | Scrapping Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. MPPWD USOR ITEM NO 14.27 P.No. 501 |
| 23 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). MPPWD USOR ITEM NO 14.1 P.No. 496 |
| 24 | 15 mm cement plaster on the rough side of single or half brick wall of mix MPPWD USOR ITEM NO 13.2.2 P.No. 468 |
| 25 | White washing with lime to give an even shade: New work (three or more coats) two or more coats MPPWD USOR ITEM NO 13.43 P.No. 474 |
| 26 | On wall Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. MPPWD USOR ITEM NO 13.67.3 P.No. 479 |
| 27 | Synthetic enamel paint on new work Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. MPPWD USOR ITEM NO 13.64 P.No. 479 |
| 28 | Epoxy paint Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work MPPWD USOR ITEM NO 13.56 P.No. 477 |
| 29 | Taking out doors, windows shutters Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: MPPWD USOR ITEM NO 15.15.1 P.No. 526 |
| 30 | M.S. sheet door and angle iron frame Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6mm for diagonal braces wc1 MPPWD USOR ITEM NO 10.5.1 P.No. 303 |
| 31 | Ceramic glazed floor tiles Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. MPPWD USOR ITEM NO 11.49 P.No. 346 |
| 32 | Ceramic glazed wall tiles Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours & shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand) preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc , complete. MPPWD USOR ITEM NO 11.50 P.No. 346 |
| 33 | Polyethylene water storage tank Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank MPPWD USOR ITEM NO 18.28 P.No. 614 |
| 34 | Electric ceiling fan Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE. MPPWD ELECTRICAL USOR ITEM NO 30.1.2 P.No. 70 |
| 35 | LED tube rod fixture Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 18 Watt, Integral i/c batten aluminium body, PC diffuser. MPPWD ELECTRICAL USOR ITEM NO 31.3.3 P.No. 73 |
| 36 | LED tube rod fixture Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. MPPWD ELECTRICAL USOR ITEM NO 31.3.4 P.No. 73 |
| 37 | Wash basin Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White vitreous china wash basin size 630 x 450 mm with sigle 15 mm cp brass pillar tap MPPWD USOR ITEM NO 17.11.2 P.No. 556 |
| 38 | M.S. wire mesh Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. With 12 mm mild steel U beading. MPPWD USOR ITEM NO 9.46.2 P.No. 208 |
| 39 | water tap Providing & fixing including testing water taps.Brass Heavy Duty MPPHE SOR ITEM NO. 3.17.1 P.No. 52 |
| 40 | CPVC pipes for external work Provinding and fixing chlorinated poly vinyl chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of enginner in charge , concealed work including cutting chases and making good the walls etc. (a) 20 mm nominal outer dia pipes MPPWD USOR ITEM NO 18.7.2 P.No. 594 |
| 41 | CPVC pipes for external work Provinding and fixing chlorinated poly vinyl chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of enginner in charge , concealed work including cutting chases and making good the walls etc. (a) 50 mm nominal outer dia pipes MPPWD USOR ITEM NO 18.7.6 P.No. 594 |
| 42 | CPVC pipes internal work Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction 15 mm nominal outer dia Pipes. MPPWD USOR ITEM NO18.6.1.1 P.No. 593 |
| 43 | CPVC pipes internal work Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction 20 mm nominal outer dia Pipes. MPPWD USOR ITEM NO 18.6.1.2 P.No. 593 Please Enable Macros to View BoQ information |