Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for anti-termite treatment to the soil along the external perimeter of the building by forming a chemical barrier @ 2.25 litres of emulsion per running metre of perimeter wall, including excavation of shallow trenches where required, complete all as specified and directed. |
| 2 | M&L for anti-termite treatment to the soil in contact with the external surface of foundation (backfill side) @ 7.5 litres of emulsion per square metre of vertical surface, including necessary preparation, complete all as specified and directed. |
| 3 | M&L for anti-termite treatment to the top surface of filled earth inside plinth area @ 5 litres of emulsion per square metre of surface, complete all as specified and directed. |
| 4 | M&L for anti-termite treatment to the soil under plinth protection @ 5 litres of emulsion per square metre of surface area, complete all as specified and directed. |
| 5 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in hard/dense soil, including getting out excavated material, trimming and levelling bottom of trenches, complete all as specified and directed. |
| 6 | M&L for plain cement concrete (PCC) 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete (RCC) M-30 design mix using 20 mm graded stone aggregate as in column footings, pile caps, and plinth beams, including formwork and vibration for compaction, complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete (RCC) M-30 design mix using 20 mm graded stone aggregate as in columns, including formwork and proper compaction, complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete (RCC) M-30 design mix using 20 mm graded stone aggregate as in beams, cantilevers, bressummers and lintels exceeding 1.5 m span, including formwork and vibration, complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete (RCC) M-30 design mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, |
| 11 | M&L for mild steel TMT bars (CRS) 10 mm dia and over in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 12 | M&L for mild steel TMT bars (CRS) 6 mm to 8 mm dia in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 13 | Ditto- all as per Item no -12 above but for mild steel TMT (CRS) bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers, binders, and the like, complete all as specified and directed. |
| 14 | M&L for formwork (use and waste) to sides and soffits of plinth beams and sides of footings, foundations, etc., for rough finished surfaces of concrete, complete all as specified and directed. |
| 15 | M&L for formwork (use and waste) to sides of columns, pillars, piers, posts, and struts, for rough finished surfaces of concrete, complete all as specified and directed. |
| 16 | M&L for formwork (use and waste) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, and similar work; also splay between floor and beams; fair finished surfaces of concrete flat, complete all as specified and directed. |
| 17 | M&L for formwork (use and waste) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping), for fair finished surfaces of concrete flat, complete all as specified and directed. |
| 18 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs not exceeding 20 cm wide, and to sides of RCC/PCC bands in walls (horizontal or sloping) and similar work exceeding 10 cm but not exceeding 20 cm wide, complete all as specified and directed. |
| 19 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6), complete all as specified and directed. |
| 20 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius, in half brick thick walls, built in cement mortar (1:4), complete all as specified and directed. |
| 21 | M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces in cement mortar (1 : 4), mixed with integral waterproofing compound @ 3 % by weight of cement, finished even and smooth in two layers, complete all as specified and directed. Note ; Water proofing compound should be measured and paid separately. |
| 22 | Supply only integral waterproofing compound (WPC), complete all as specified and directed. |
| 23 | M&L for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar (1 : 6), finished even and smooth without using extra cement, complete all as specified and directed. |
| 24 | M&L for rendering 5 mm thick on fair faces of concrete surfaces in cement mortar (1 : 3) as in ceilings, finished even and smooth without using extra cement, complete all as specified and directed. |
| 25 | M&L for applying two or more coats of 100 % premium acrylic exterior emulsion paint having VOC < 50 g/litre and UV resistance conforming to IS 15489 : 2004, with alkali, fungal and dirt resistance, of required shade (Company Depot-tinted) with silicon additives @ 1.43 litre / 10 sqm over and including one coat of exterior primer @ 0.90 litre / 10 sqm on new surfaces, complete all as specified and directed. |
| 26 | M&L for preparation of new undecorated plastered or unplastered surfaces of ceilings and applying two coats of whitewash, complete all as specified and directed by the Engineer-in-Charge. |
| 27 | M&L for applying two coats of oil-bound distemper on new wall surfaces including preparation of surface, complete all as specified and directed. |
| 28 | M&L for 75 mm thick plain cement concrete (1 : 3 : 6) type C-2 using 40 mm graded stone aggregate, laid in panels as in plinth protection, finished even and smooth without using extra cement, including necessary formwork to edges and filling of joints with bituminous sealing compound, complete all as specified and directed. |
| 29 | M&L for broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and well rammed to a true surface, complete all as specified and directed. |
| 30 | M&L for 75 mm thick plain cement concrete (1 : 4 : 8) type B-1 (nominal mix) using 20 mm graded stone aggregate as in sub-floors, complete all as specified and directed. |
| 31 | M&L for 40 mm thick plain cement concrete (1:2:4) type B-2 using 40 mm graded stone aggregate as in floor sub-base, finished rough to receive floor finish, complete all as specified and directed. |
| 32 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular), each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in area, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4), complete all as specified and directed. |
| 33 | M&L for glazed ceramic coloured tiles in vertical surfaces, of size 350 × 250 × 7 mm or 450 × 350 × 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified and directed. |
| 34 | M&L for double charge premium quality vitrified ceramic tiles 10 mm thick (square or rectangular), polished, each tile exceeding 0.36 sqm but not exceeding 0.42 sqm in area, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4), complete all as specified and directed. |
| 35 | M&L for 20-22 mm thick granite maching cut mirror polished as in steps, window cills, cooking platform, working table etc and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (colour of granite will be decided by the GE/Engr-in-Charge). |
| 36 | Extra over granite work for edge polishing, chamfering, nosing, grooving, bevelling, and similar operations as in steps, jambs, and edges, complete all as specified and directed. |
| 37 | S&F factory made solid PVC prelaminated door frame of size 50 mm × 47 mm, made out of 5 mm thick plain colour PVC sheet of single side prelaminated wood grain printed sheet (used instead of plain colour PVC sheet), edges painted to match with prelam sheet, reinforced with mild steel square tube, supplied and fixed in opening complete as per specification and drawing, all as specified and directed. |
| 38 | S&F factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles), with 2, 4, or 6 mm raised panel design, 4 mm thick PVC prelaminated moulded sheet on the front face and 4 mm plain or prelaminated PVC sheet on the back face, core consisting of PVC battens, supplied and fixed in door frame, complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F aluminium anodised barrel tower bolts of extruded section, length of bolt 200 mm, complete all as specified and directed. |
| 40 | S&F aluminium handles, 200 mm size, cast type, anodised, complete all as specified and directed. |
| 41 | S&F butt hinges 100 mm size, medium weight, stainless-steel type, fixed complete all as specified and directed. |
| 42 | S&F aluminium alloy anodised sliding door bolt, 250 mm long, with hasp, staple (bolt type), fixing clips of sheet or cast/extruded sections, and fixing bolts of extruded sections or cast aluminium alloy, complete all as specified and directed. |
| 43 | S&F vitreous-china wash basin, white, flat-back pattern, size 550 × 400 mm, including 32 mm brass waste coupling, waste pipe, and cast-iron or MS brackets, complete all as specified and directed. |
| 44 | S&F vitreous-china wash-down water-closet pan (pedestal pattern), white, including fixing bolts, syphonic-action low-level PVC flushing cistern of 10-litre capacity (Commander make or equivalent) and 32 mm PVC flush pipe, complete all as specified and directed. |
| 45 | S&F, in repairs, for oval-shaped coloured vitreous-china wash-hand basin (WHB), table-top fancy type, overall size 595 × 380 mm , including 32 mm chromium-plated waste coupling, PVC waste pipe, and granite counter slab of black colour size 1.20 m × 0.60 m, edges rounded, mirror-polished, supported horizontally on 35 mm thick cuddapah stone slab and vertically on two Nos 35 mm thick slabs, complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F vitreous-china water closet (squatting pan) “Orissa” pattern, size 580 × 440 mm, white, with integral footrest and ‘P’ trap (excluding flushing cistern) but including PVC flush pipe and lime-concrete bedding as in repairs, complete all as specified and directed. |
| 47 | S&F vitreous-china European-type wash-down water closet pan (pedestal pattern), white, including plastic water-closet seat (black or white) closed pattern with flat bottom (with MS or CP hinging device), fixing bolts, ‘P’ or ‘S’ trap, and all necessary inlet/outlet connections, including syphonic-action low-level PVC flushing cistern of 10-litre capacity (Commander make or equivalent) and 32 mm PVC flush pipe, complete all as specified and directed. |
| 48 | S&F vitreous-china urinal, half-stall type (back-to-corner wall type), complete, including bedding against wall in cement mortar (1:2), securing with brass screws, pointing around urinal, fixing automatic flushing cistern with brackets, flush pipe, grating, and union for discharge pipe (exclusive of supply pipe to cistern, trap, and waste pipe) (Make: Cera Cat. No. S4020107 or equivalent), complete all as specified and directed. |
| 49 | S&F, in repairs, for seat cover for pedestal water-closet pan, plastic seat (black or white), closed pattern with flat bottom and cover, with mild-steel chromium-plated or aluminised hinging device, complete all as specified and directed. |
| 50 | M&L for urinal spreader of brass body, chromium-plated, fixed with 15 mm dia pipe suitable for urinal, complete, fixed in repair, all as specified and directed (Make : Cera Cat No. F8070201 or technocommercial equivalent). |
| 51 | S&F 15 mm bore galvanized-steel tubes, medium grade, for flush pipes or water-supply pipes, fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 52 | S&F 20 mm bore galvanized-steel tubes, medium grade, for flush pipes or water-supply pipes, fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 53 | &F 15 mm bore chromium-plated fancy-type stop cock (concealed type) with long shank and cup, screwed down, suitable for high pressure for iron pipes or unions, fixed in position (weight not less than 400 g), complete all as specified and directed. |
| 54 | S&F 15 mm bore CP stop valve/angle valve, fancy type, with long shank and cup (concealed type), cast-copper-alloy, screwed down for high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 55 | S&F 15 mm bore chromium-plated fancy-type stop cock (concealed type) with long shank and cup, screwed down, suitable for high pressure for iron pipes or unions, fixed in position (weight not less than 400 g), complete all as specified and directed. |
| 56 | S&F 15 mm bore CP stop valve/angle valve, fancy type, with long shank and cup (concealed type), cast-copper-alloy, screwed down for high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 57 | S&F gun-metal globe or gate valve (ISI marked), 20 mm bore, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed. |
| 58 | S&F ball-type PVC valve, 20 mm bore, high pressure, with polythene float and fly-nut, screwed for iron pipe or brass ferrule, complete all as specified and directed. |
| 59 | S&F rotational-moulded polyethylene water-storage tank, cylindrical vertical with closed top, hoisted and fixed in position, capacity 2000 litres, all as specified in SSR Part I and directed. |
| 60 | S&F PVC connection 15 mm size, with PTMT nuts, length 450 mm, complete all as specified and directed. |
| 61 | Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 62 | S&F stack clamps made out of 50 mm × 5 mm flat iron and 16 mm dia round iron stays, including bolts, nuts, and securing ends of stays to wall or roof, for 100 mm bore PVC (SWR) pipe, complete all as specified and directed. |
| 63 | S&F PVC (SWR) vent cowl, 110 mm dia, complete all as specified and directed. |
| 64 | Supply & Fixing 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 75 mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 65 | S&F PVC (SWR) bends, any radius, 110 mm dia, provided with access door, complete all as specified and directed. |
| 66 | S&F PVC (SWR) junction single (Single ‘T’), equal or unequal, 110 mm dia, complete all as specified and directed. |
| 67 | M&L for PVC (SWR) floor trap, 75 mm dia, plain type, with grating, including jointing with solvent cement, complete all as specified and directed. |
| 68 | S&F PVC (SWR) gully trap 125/110 mm dia, setting and jointing with solvent cement, including necessary excavation and connection to drain line, complete all as specified and directed. |
| 69 | S&F bevelled edge mirror of selected quality glass, size 600 × 450 mm, mounted on 6 mm thick asbestos cement building board or commercial plywood backing, fixed to wooden plugs with chromium-plated screws and cup washers, complete all as specified and directed. |
| 70 | S&F health faucet (ABS body), chromium-plated, suitable for 15 mm dia pipe, complete with 1.25 m long flexible tube and ABS wall hook, including all necessary connections and fixing in position, complete all as specified and directed. |
| 71 | S&F chromium-plated soap dish, brass or stainless steel base, with wall mounting bracket and screws, fixed to wall including necessary plugs and CP screws, complete all as specified and directed. |
| 72 | S&F chromium-plated tubular towel rail, fancy type, 20 mm dia, ‘D’ shape, 600 mm long between flanges, including chromium-plated wall brackets, screws, and rawl plugs, complete all as specified and directed. |
| 73 | S&F brass chromium-plated shower rose, 75 mm dia, fancy type with long body, including connection to steel pipe or union, complete all as specified and directed. |
| 74 | S&F Grating dome 100 mm dia, PTMT material, including fixing to outlet pipe with solvent cement or CP screws, complete all as specified and directed. |
| 75 | S&F Grating dome 125 mm dia with waste hole, PTMT material, fixed to drain opening with solvent cement, complete all as specified and directed. |
| 76 | S&F high-density polyethylene (HDPE) pipe 40 mm bore, pressure rating 6 kg/cm², complete with necessary sockets, elbows, bends, and fittings, fixed to wall or in floor, or laid under floor, complete all as specified and directed. |
| 77 | M&L for rendering 20 mm thick in cement mortar (1:4), mixed with and including integral waterproofing compound @ 3% by weight of cement, applied over roof slab, finished even and smooth, complete all as specified and directed. |
| 78 | M&L for preparing plastered surface of roof slabs, chhajjas, and similar surfaces by brooming clean, removing all dust and loose particles, and applying evenly one coat of approved bituminous primer @ 0.20 kg/sqm of surface area, complete all as specified and directed by Engineer-in-Charge. |
| 79 | M&L for APP-based polymeric waterproofing membrane, minimum weight 3 kg/sqm and minimum thickness 4 mm, reinforced with polyester non-woven fabric (weight not less than 150 g/sqm), laid on primed surface by torch-applied method with proper overlaps and sealing of joints, complete all as specified and directed. |
| 80 | M&L for plain cement concrete (PCC) 100 mm thick, type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub-base, finished rough, complete all as specified and directed. |
| 81 | M&L for 25 mm thick layer of clean, coarse sand laid under interlocking paver blocks, levelled and well compacted, complete all as specified and directed.(taken as separate item and considered in paver blocks) |
| 82 | M&L for machine-pressed precast concrete interlocking paver blocks, any shape or size, 80 mm thick, M-35 grade, using grey cement with approved pigment, conforming to IS 15658:2006, laid over 25 mm thick sand cushion, including compaction and finishing, complete all as specified and directed by Engineer-in-Charge.(Note: Sand cushion shall be measured separately.) |
| 83 | M&L for plain cement concrete (1:2:4), type B-1, using 20 mm graded stone aggregate as in coping concrete, finished fair and even, complete all as specified and directed. |
| 84 | M&L in repair for RCC pipes, class NP-2, 200 mm bore, laid and jointed with collars and cement mortar (1:1), complete all as specified and directed. |
| 85 | M&L for cement concrete (1:3:6), type C-2, using 40 mm graded stone aggregate as in concrete bed to 200 mm dia drain pipes, including packing under and haunching against sides of pipes after laying, complete all as specified and directed. |
| 86 | Extra over drain pipe concrete work for forming fair-finished channels, inner girth not exceeding 30 cm, using extra cement for smooth finish, complete all as specified and directed. |
| 87 | M&L for rendering 15 mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement, complete all as specified and directed. |
| 88 | M&L for precast cement concrete cover slabs for manholes, chullah hoods, chajjas, water troughs, mangers, shelves, and similar items with plain faces, using 1:2:4 type B-1 (20 mm graded stone aggregate) set in cement mortar (1:4), complete all as specified and directed. |
| 89 | S&F rolled mild-steel sections of Grade Fe 410-W (Grade E-250) Quality A, as in posts, runners, rafters, purlins, steps, and similar structural members, fixed with connecting plates, including bending, welding, and all other connections, complete all as specified and directed. |
| 90 | M&L for mild-steel plates (plain or chequered), channels, squares, or notched sections (ordinary or countersunk) including drilling or forming holes without any attachments, Fe 410-W (Grade E-250), complete all as specified and directed. |
| 91 | S&F 2 mm thick fibre-glass-reinforced translucent plain or corrugated sheeting with two corrugation side laps, fixed with L-type, J-type, or cranked hooks with washers in lieu of screws, as in roof or wall cladding, complete all as specified and directed. |
| 92 | M & L for Framed work such as grills, gratings, with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; and framework of water tanks and similar work conforming to Fe 290 (Gde E-165), complete all as specified and directed. |
| 93 | Cutting into existing manholes or septic tanks to make connections for 150 mm dia pipes, including dismantling and making good the disturbed portions in cement concrete and brickwork, complete all as specified and directed. |
| 94 | Returning, filling in, including spreading, leveling, watering, and well ramming in layers not exceeding 25 cm thick, using approved excavated soil, complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F 3 mm thick aluminium composite panel cladding of approved metallic colour/shade, fixed to beams, columns, or slabs (circular or rectangular shape), including cutting, notching, and bending to shape as required; jointing with silicone sealant of approved colour; fixing with aluminium tubular hollow section 25 × 25 mm @ not exceeding 900 mm c/c to hold the ACP panels, complete all as specified and directed.(Note: Colour/pattern of ACP sheet shall be approved by GE.) |
| 96 | S&F 10 to 12 mm thick toughened glass for door shutters, partitions, and shelves, including all fittings such as glass handles, SS studs, cubical hinges (glass-to-glass and glass-to-wall types), 19/20 mm SS support pipes, fittings for pivots, and necessary hardware, complete all as specified and directed by Engineer-in-Charge. |
| 97 | M& L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by EIC. |
| 98 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 99 | Dismantling battens for tiles, shingles, or similar roof materials of any size, including tilting fillets and fixtures, complete all as specified and directed by Engineer-in-Charge. |
| 100 | M&L for Mangalore-pattern roof tiles, interlocking at side joints, laid dry and properly aligned, complete all as specified and directed. |
| 101 | Demolition of brick or stone masonry built in cement mortar, including all quoins, arches, and pillars but excluding ashlar facings, dressed stonework, and precast concrete articles, complete all as specified and directed. |
| 102 | Demolition of reinforced cement-concrete roofs, floors (other than ground floors), beams, staircases, landings, chajjas, and similar suspended RCC works of any description, complete all as specified and directed. |
| 103 | Removing debris exceeding 1.5 km but not exceeding 10 km and depositing where directed, in soil outside MD land, complete all as specified and directed. |
| 104 | Excavating over areas , in Hard/dense soil n exc 1.5m deep and getting out exc complete all as specified and directed. |
| 105 | Excavation in post holes in hard/dense soil (or similar holes) each n exc 0.5 cum getting out.returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and making good surface complete all as specified and directed. |
| 106 | M&L for PCC 1:3:6 type C-2 ( 40mm graded stone aggregate) as in foundation,filling and mass concrete etc complete all as specified. |
| 107 | S&F motorised steel rolling shutters, as specified including top cover,anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete but gear operated type with bevel gear box and crank handle 1.25mm thickness of laths etc complete all as specified. |
| 108 | S&F safety lever locks mild steel with 4 levers for rolling shutters etc complete all as specified. |
| 109 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 (40mm graded stone agg) as in sub base etc complete all as specified. |
| 110 | M&L ready mix Concrete of M-30 as in basement floors including finishing the surfaces even and smooth without using extra cement all as specified. |
| 111 | Demolition of unreinforced cement-concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed. |
| 112 | M&L for roughening surfaces of old concrete surfaces by picking, sweeping cleaning and washing down with water to remove dust etc including taking down tarfelt and 15 mm thick rendering in cement mortar 1:4 finished even and smooth without using extra cement including mixed with water proofing compound as per manufacturer instructions (WPC shall be measured and paid separately). |
| 113 | M&L PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling course on roof surfaces and coping etc. |
| 114 | M & L Podium waterproofing system W159 SBS IN 1.5, a 1.5mm thick with modified bitumen waterproofing membrane with cross laminated HDPE film for wet application on the surfaces. The membrane shall be applied after making the surfaces dry conditionand applying a bonding slurry W1 IN. The membrane is then unrolled and pressed into the fresh slurry after removel of the releaseliner. both lng and short edges of the membrance are overlapped by min 80mm and firmly pessed together using a roller with stagged overlaps. The membrance shallhave a ensile strength-25 MPs according to ASTM D4-12; elengation 500% according to ASTM D412; resistance to static puncture-900N according to ASTM E154, adhesion in peel-1.N/mm according to ASTM D 903 mod, resistance to lateral water migration-71m according to ASTM D5385 mod. |
| 115 | Supply only integral water proofing compound complete all as specified. |
| 116 | Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame) |
| 117 | Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame) |
| 118 | Taking down cement plaster of any description on brick, stone or concrete surfaces of walls including raking out joints, hacking for key, scrubbing down with water upto 3 rd floor of bldg incl scaffolding complete all as specified and directed. |
| 119 | M&L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a metallic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary two legged MS pipe scaffolding as wherever required incl curing required upto G plus 3rd floor bldg complete all as specified and directed. |
| 120 | M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even all as specified and directed. |
| 121 | M&L for preparation of newly plastered surfaces of wall, applying two coats of oil emlusion distemper over a coat wall care putty of 3 mm thick and alkali primer. |
| 122 | Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water and applying two coats of oil bound distemper over a coat of primer. |
| 123 | M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper all as specified and directed |
| 124 | Preparing old decorated surfaces as in walls soffits & facias of beams, chajjas etc complete by washing, rubbing down & stopping making good the surface & applying 2 coats of weather proof Acrylic based paint (100% Acrylic) exterior Gde . |
| 125 | Preparing new plastered surfaces as in walls soffits & facias of beams, chajjas etc complete by washing, rubbing down & stopping making good the surface & applying 2 coats of weather proof Acrylic based paint (100% Acrylic) exterior Gde . |
| 126 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing and direction of Engineer-in-Charge. |
| 127 | S&F powder coated aluminium of various section as required for doors, window & partion etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant etc all as specified and as directed by Engr- in- charge. |
| 128 | S & F sheet glass of 4.8 mm thick selected quality in square and exceding 0.5 Sqm in each pane |
| 129 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple etc. |
| 130 | S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed. |
| 131 | S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified. |
| 132 | S&F butt hinges 100 mm Stainless steel hinges medium weight. |
| 133 | M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed . |
| 134 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) and rabbish of the premises. |
| 135 | Dismantling stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness all as specified and directed. |
| 136 | M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5mm graded aggregate as in floor finished even and fair all as specified. |
| 137 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match. Note : Engr-in-Charge will select sample from latest catalouge of 2019-20. |
| 138 | M&L double charge premium quality vitrified ceramic light shade tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm),but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 139 | M &L for machine cut mirror polished kota stone slab flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 140 | M &L for machine cut mirror polished kota stone slab 18 to 20 mm thick as in skirting/vertical surfaces jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed. |
| 141 | Rounding to edges of stone slabs on edge, such as in steps, cooking platform and other similar situations |
| 142 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 143 | Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed. |
| 144 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed |
| 145 | S&F for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS1161-1979. |
| 146 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets of any thickness including cover fillets all as directed. |
| 147 | M&L for false ceiling made out of 600 x 600 x 4 to 6 mm thick ceiling board/tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50 x 40 x 0.63 mm and cross tee of size 23.50x23.50x0.63 mm and angle size 19x19x0.63 mm including 3 mm GI wire for suspending holts necessary washers nut/cleats/pin hook etc for securing frame work to ceiling to the snap grid including provn of necessary holes/cutting for providing light/far as required including making necessary recesses/projected pattern complete all as spoecified and as directed. |
| 148 | Taking down PVC wastage and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed. |
| 149 | S&F 160 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floor etc with and including fixing clips bends elbow, shoes bends etc (Note :- Measurement shall be taken along the centre line of the pipes) bracket suitable for 160mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 150 | Supply only cast iron 'P' trap 100mm dia |
| 151 | S&F in repairs PVC valveless syphonic action type ,flushing cistern Low level white, with inlet ball valve ,float and handle 10 Ltr capacity including brackets. |
| 152 | S&F in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm dia. for low level cistern |
| 153 | S&F in repair wash hand basin vitreous china white (flat back) of size 550x400mm including bracket 15mm dia 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified, |
| 154 | S&F in repairs fancy type cock suitable for counter top wash basin 15 mm dia, screwed for iron pipe and fixed complete all as specified. |
| 155 | S&F in repairs fancy type two way bib cock 15 mm dia, screwed for iron pipe and fixed complete all as specified, |
| 156 | S&F 32 mm dia WHB/urinal flexible waste pipe all as specified and directed. |
| 157 | S&F bevelled edge mirror (600mm x 450mm) of selected quality glass, mounted on 6mm thick AC building board or commerical playwood and fixed to wooden plugs or screwing in all conrner with chromium plated brass screws and cup washers all as specified and directed. |
| 158 | S&F overhead shower of 100 mm round shape single flow (ABS Body chromium plated with gray face plate) with rubit cleaning system all as specified and directed. |
| 159 | Taking up or down existing GI water tubing complete with all fittings of 15 mm bore |
| 160 | Taking up or down existing GI water tubing complete with all fittings of 20 mm bore |
| 161 | M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint. |
| 162 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint. |
| 163 | M & L preparation of plastered surfaces and applying two coats of smart Care Damp block 2K or equivalent acrylic polymer modified cementious high performance coating including smart care crack seal coat complete all asspecified and directed |
| 164 | S&Fin repairs 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall vertically with screws and C/C deistane 30 CM to make PVC frame as per specification and drawing. |
| 165 | S&F in repairs PVC wall /ceiling paneling consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing. |
| 166 | S&F in repairs 18/19 mm thcik prelaminated partical board exterior grade prelaminated one side with lamination and other side balancing white lamination fixed with screw to frame work cupboard, pelmets etc including 6 mm thick teak wood beading all around complete all as specified and directed. |
| 167 | Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge. |
| 168 | M & L for point wiring in repair with FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm size 1100 volts grade drawn through and including non metalic rigid PVC casing caping not less than 25mm width with all accessories fixed on wall including FRLS PVC insulated, unsheathed multistranded copper onductor cable of size 1.5 sqmm as earth continuty conductor connecting to common earth dolly and PVC moulded box ISI marked for having the switches, switch sockets regulator etc complete all as specified for following:- |
| 169 | One light point controlled by one switch |
| 170 | One ceiling fan/wall fan/exhaust fan point controlled by one switch |
| 171 | One 5 Amps switch socket combination on independent board |
| 172 | One 5A flush type switch socket point on same board |
| 173 | M&L for point wiring complete with 2.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make drawn through & including PVC casing caping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessoriesi with cover plate and frame including one PVC insulated & unsheathed multistranded copper conductor 2.5 Sq. mm as earth continuity conductor connected to common earth dolly for single board having 1 x15 Amp switch socket point for independent board complete including required size and numbers moduler box and cover plate all as specified & directed. |
| 174 | M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, ISI marked, not less than 25mm PVC casing caping with all accessories fixed on wall/ceiling/truss with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessoriesi with cover plate and frame and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0 sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including required number and size of modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. |
| 175 | M&L for submain in repair wiring with 2 runs of 10 sqmm and one run of 10 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing caping not less than 25mm width ISI marked with all accessories like PVC elbow etc fixed on wall complete including connecting up all as specified and directed. |
| 176 | M&L for submain wiring in repair with 2 runs of 4 sqmm and 1 run of 4 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing caping not less than 25mm width ISI marked with all accessories like PVC elbow, etc fixed on wall complete including connecting up all as specified and directed. |
| 177 | M&L for sub-main wiring with 4 runs of 10.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green |
| 178 | M&L for sub-main wiring with 4 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green |
| 179 | Supply laying & testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wirearmoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25sqmm 4 core in trenches/along wall/floor etc incl required material for fixing arrangement complete all as specified and directed. |
| 180 | S&F in repair LED recess mounted type fitting 36W 2'x2' CRCA LED (min 120 lumen/watt) Slim panel with recess mounting, powder coated white CRCA full glow LED panel including control gear and lamp complete all as directed and specified by Engr-in-Charge |
| 181 | Supply and fix in repair decorative Post top lantern 45 Watts includig fixing of suitable for 60mm OD pipe for the mounting, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection and making good distrubed surfaces all as specified and directed with post top lantern parameters as follows:- system wattage 45 W, 6500K, IP protection = IP 65, PF≥ 0.90, Resistance to impact and corrosion. Glare free and better uniformity Milky version |
| 182 | Supply and fixing in repair of LED 60W (min 120 lumen/watt) Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed by EIC. |
| 183 | Supply and fixing in repair walll/surface mounted 20W LED batten fitting (min 120 lumen/watt) engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. |
| 184 | Supply and fix in repair switch modular type 1 way 6 Amps 1 module 240 volts flush type all as specified and directed by Engr-in-Charge. |
| 185 | Supply and fix in repair switch modular type 1 way 16 Amps 1 module 240 volts flush type all as specified and directed by Engr-in-Charge. |
| 186 | Supply and fix in repair modular socket 6 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge. |
| 187 | Supply and fix in repair modular socket 16 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge. |
| 188 | S&F Modular fan regularor, 120W, 2 module all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |
| 189 | S&F Modular fan regularor, 120W, 2 module all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail