| 1 | Demolition of brick work or stone masonry built in cement mortar complete all as specified and directed. |
| 2 | M&L brick work with old size bricks, straight or curved on plan exc 6m mean radius, in cement mortar 1:4 complete all as specified and directed. |
| 3 | All as per ser item No 02 here-in-before but except brick complete all as specified and directed.Note: Serviceable bricks retrieved from item No 01 shall be reused. |
| 4 | Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished over and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished over and smooth without using extra cement complete all as specified and directed. |
| 7 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 8 | M&L PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in kerb or mud stops rounded or chamfered on edges for copping, including weathering slightly rounded or chamfered including form work (Straight or curved) complete all as specified and directed. |
| 9 | M&L for broken glass coping on top of walls in cement mortar 1:3 complete all as specified and directed. |
| 10 | M&L applying two coats of cement base paint including preparation of newly plastered surface of wall complete all as specified and directed. |
| 11 | M&L applying one coat of cement base paint including preparation of old plastered surface of wall complete all as specified and directed. |
| 12 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 13 | M&L hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 14 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 15 | M&L two coats of synthetic enamel paint over a priming coat with red oxide over steel surface over 10 cm width or girth complete all as specified and directed. |
| 16 | M&L one coat of synthetic enamel paint over old steel surface over 10 cm width or girth complete all as specified and directed. |
| 17 | S&F in repair Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 8 RM, having a core wire of high carbon spring steel of high tensile strength. The punched tape and copre wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) to provided protection against out door exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 ± 0.5 mm C/C. The weight of each coil shall be 8 ± 5% Kgs without packing material and coil lenth 8 Mtr (maximum) when opened up each coil would with bituminzed hessian cloth for providing protective packing Ref specification No CQAE/5660/1620/a for raw material and drawings IMGA-0112/B (Sheet 1 of 2), IMPD-1821, IMPD-1822 complete all as specified & directed. |
| 18 | S&F in repair for galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed. Please Enable Macros to View BoQ information |