| 1 | Scraping of Cement Plaster |
| 2 | 12.5 mm thick cement plaster 1:4 |
| 3 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 4 | Supplying Pressed steel sheet frames (chowkhat)consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. |
| 5 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position.35mm thick |
| 6 | Tile terracing laid dry over roof consisitng of one layer of tiles 22.86x11.43x3.83 including grouting with cement sand mortar 1:4 top surface to be left clean after wire brushing |
| 7 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 8 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 9 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 10 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 11 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 12 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 13 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 14 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m. |
| 15 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) |
| 16 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame includingfixing & connections and petty material etc.:-One Way 6amp. Switch Flush Piano type |
| 17 | Step type Fan Regulator Flush Piano type (Switch size) |
| 18 | TV Socket Flush Piano type (Switch size) |
| 19 | Bakelite Batten Holder (Large size) |
| 20 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 21 | P/F Chain Link of 4 ft height with 4 inch square boxes made up of 10 guage of steel wire with binding wire complete in all respect |
| 22 | Repair of Corner Pillar Complete |
| 23 | Providing, Laying , fixing & jointing of 110 mm o/d 6 Kgf. / sqcm P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients,cutting, jointing and testing complete as per specifications. (Excavation Manually) |
| 24 | Connection with exisitng as per pipe line to correct alignment analysis and gradionts cutting jointing and testing with new pipe line complete in all respect. |
| 25 | Construction of Cement Concrete Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing Please Enable Macros to View BoQ information |