| 1 | Excavation in foundation in ordinary soil (loam,clay or sand) including lift upto 1.50 and lead upto 30M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30M from the foundation trenches. SI No.251(a) |
| 2 | Concrete with 4cm. gauge stone ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 3 | M-150 brick work in 1:4 cement and coarse sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge. |
| 4 | M-150 brick work in 1:4 cement and coarse sand of 1.25 fineness modulus mortar in superstructure including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge. |
| 5 | 12mm thick cement plaster with 1:4 cement and fine sand of 1.25 FM mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tools and plants etc, required for proper completion of the work as per direction of Engineer-in-charge. |
| 6 | RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. |
| 7 | RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. |
| 8 | 2.5 cm (1\\") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand 2 cm.(1\\") graded approved stone grit, laid in panels finished with 3mm. (1/8\\") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm(3\\") thick base concrete consisting of cement, fine sand of 1.25 fineness modulus and brick ballast 4 cm. (11/2\\") gauge in the proportion of 1:4:8 and removing any overlapping mortar at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. |
| 9 | Dismentling of old brick laid flat/C.C. interlocking Tiles. (New Item 4/ch-20) |
| 10 | Construction of granular sub-base by providing coarse graded material, sperading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (Grade-I) (Ref. to Mort&H Specification No. 401) (A.R) |
| 11 | Laying of Interlocking Tiles. Ch. No.20 (New Item 17)/2022 |
| 12 | Cement concrete with 2cm gauge approved stone grit, coarse sand & cement in the proportion of 4:2:1 i/c supply of all materials,labour,Tools & plants etc.required for proper completion of the work. |
| 13 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as per specified and as directed by the Engineer-in-Charge. (D.S.R. 11.56.2) |
| 14 | S/F 6 mm (1/4\\") china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry ,jointing and polishing complete, (S.I. No.14.22/2022) |
| 15 | painting or varnishing with valsper or other approved high grade enamel or super par synthetic clean varnish commplete one coat over previously painted surface including supply of all materials labour tools & plants etc. (S.I. No 641+642/2022) SOR |
| 16 | M.S.iron work of small size and section such as holding down bolts, hold fast, tie roads grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. S.I.NO.....502(a)/2022 |
| 17 | Supply And Fixing of Galvanized iron corrugated roofing Sheet. (S.I.NO. 536/2020) |
| 18 | M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire (S.I. No. 504/2022) A.R. |
| 19 | S/F of kerb stone.(DSR 4.6.1/2023) 8726.85x.7281=6354.01 |
| 20 | P/F CPVC pipe 40 mm (S.I.No.21.01 SOR 2022) CH.21(B) |
| 21 | P/F CPVC pipe 15 mm (S.I.No.21.01(a)SOR 2022CH.21(B) |
| 22 | P/F C.P. brass long nose bibe cock(S.I.No.21.08 CH.21(B) |
| 23 | Water connection (Bond No.917/MDA/MZN/2024-25) |
| 24 | P/F water closet squatting pan (indian type W.C. pan) (SI.No. 21.12/2022) |
| 25 | P/F white vitreous china flat back half stall urinal of size 580x380x350 mm (SI.No. 21.14/2022) |
| 26 | P/F wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. (SI.No. 21.16/2022) |
| 27 | Finishing wall with two coat of paint. (SI.No.15.22 New item /2022) |
| 28 | Wiring point for light in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, GP box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed i/c matching colour wash. |
| 29 | Wiring point for fan/ fresh air fan (light duty exaust fan) in PVC conduit with 1.5 sq. mm.(SI.No.140c)/SOR/2018/Elec |
| 30 | Supply And fixing of exaust fan. Please Enable Macros to View BoQ information |