Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | HSR Itmes |
| 2 | 11 kV SWITCHYARD / TWO POLE (DP) STRUCTURE:Supply, Installation, Testing and Commissioning of 11 kV, 3 Phase, 50 Hz, Two Pole Structure made of 6` X 3` `I` section girder having min. 9mtr. length, 4` X 2` M.S. channels, angles, clamps, nuts, bolts, stay wires including earthing system etc. suitable for erection of following / indicated accessories duly connected with ACSR conductor as per approved drawings and in compliance with requirements of IS/IEC / Power Supply Co.:(a) 11kV 200A DO (drop out) fuses with S.R.B.P. tubes carries (03 nos.) (b) 11kV 400A G.O.D. switch complete with insulators, operating handle with galvanized pipe, square bar etc. (01 set) (c) 11kV lightning arrestors with clamps (03 nos.) (d) 11kV shackle (Disc/Pin/Post) as required insulators (06 nos.)(e) ACSR Dog Conductor (mini. 30Mt.) (f) 11 kV fiber operating rod (g) 20 mm dia. GI stay sets (2 sets), required foundation etc. and to be painted with two coat of red oxide and final two coat of Aluminium paint at site as per IS, Specification and Drg. |
| 3 | H.T. INDOOR SWITCH GEAR PANEL SITC of 11 kV, 500 MVA, 630A, Indoor, Extensible type, Horizontal draw out, Motorised spring charging mechanism, 3 breaker Vacuum Circuit Breaker Panel (1 No. Incomer plus 2 Nos.outgoing), with EC grade copper busbars along with required Resin cast CT Dual primary and secondary, Cl: 0.5/5P10, 15VA, Digital MFM with RS 485 with 3 Line Display, Class-0.5s and PT (dual secondary) Cl:0.5/3P, min 200VA or higher for metering and protection, 110V DC power pack for incoming and outgoing feeder, Annunciator, Hooter, Indicating lamps, Numerical Protection relay (Current and Voltage Based) with RS 485 with combined protection for 3O/C plus 1E/F, S/C, Under and Over Voltage, Transformer Protection Aux. relay etc. High speed tripping relay, Trip ckt supervision relay, Fuse failure relay, Digital Power factor meter, Ammeter, Voltmeter (Only I/C), A/M switch suitable for PLC/SCADA etc. complete in all respects as per IS, Specification. |
| 4 | SITC of H.V. CABLES 11 kV (E), 3C x 240 sq.mm., Aluminium, extruded innersheath, Armoured, XLPE , H.V Cable as per IS 7098 (part 2) and Tech. Specification. (PSC DP Structure to Client DP Structure, Client DP Structure to HT Panel, HT Panel to Transformer 1 and 2) |
| 5 | Supply and levelling of Switch yard and transformer yard using gravel, fine sand and other required filing material, enmarked for the Switchyard and Transformer yard including removing of trees or boulders etc. if any. The general level of the yard shall be at a convenient level for movement of man and material and it should match with FGL and as per Specification and Drg. |
| 6 | Supply and Installation of GI Chain link fencing frames with L angle/Channel post around Transformer yard etc. as per Specification and Drg. |
| 7 | SITC of H.V. CABLES SITC of 3.0 mtr wide gate with GI chain link as per Specification and Drg. |
| 8 | STAND ALONE VFD CUBICLE PANEL FOR 75kW SUBM. NC PUMP :-SITC of Standalone VFD Panel (LT MCC panel, 50kA) for Min. 75kW Motor, compartmentalized, Floor Mounted / stand mounted as per site condition / requirement, operating height maximum 1800/1900 mm, Extensible on both ends, suitable for Manual and Auto operation. Auto operation and moitoring through PLC/SCADA: Manual from panel when in remote mode complete in all respects as per Tender SLD / Specification / IS and including following as minimum:Panel comprising of Min. 200A TPN Microprocessor MCCB LSIG as incomer,VFD with inbuilt RS 485 for 75 kW Motor or higher as per pump manufacturer reco. with VFD rating minimum (148A @ 50°C) with suitable derating with detachable type door mounted display key pad, 200A, AC3 duty Line contactor, Semi conductor fuse, Input Choke having Max. 2% voltage drop shall be provided, rating as recommended by VFD manufacturer and Output choke as recommended by VFD OEM for harmonic mitigation, VFD with 3C3 Confromal coating, MFM Cl. 0.5 with RS-485, Resin Cast CT Cl: 0.5, SPP, Space heater, A/M, L/R switch, R,Y,B, On, Off, Trip, Speed Up and Speed down Indicating lamps, Start, Stop, Speed Up and down Push buttons. Heavy duty 6` Metalic Housing and Metal Impeller / Blade / Vanes of Minimum 2nos. or higher as required at the top of the panel with canopy/hood etc. Voltage and current harmonics shall be as per recommendations of the IEEE-519 2014 or latest revision.STAND ALONE PANEL MINIMUM SIZE: 1.2M (W) X 1.5M (H) X 1.0M (D) |
| 9 | SITC of 135 KVAR at 415V, APFC Panel Filter Panel with 7% Detuned reactors,compartmentalised, Floor mounted, extensible type on both sides with Horizontal bus bar arrangement as per site requirement and complete in all respects as per SLD / Specification / IS and including following as minimum:(1) INCOMER: 1.1 320A, TPN, 50 KA TM MCCB with Digital Voltmeter with VSS, Digital Ammeter with ASS, Resin Cast CT- Cl : 1.0,10VA, A/M, L/R switch, Indicating lamps, Push buttons etc.1.2 Microprocessor based APFC Relay,144sq.mm, 12 STEP with RS 485 with minimum operating current 10mA.2. OUTGOING CAPACITOR FEEDER:Capacitor feeder of following rating comprising of TPN MCCB/MCB with ON and TRIP Indication, Capacitor duty contactor,Heavy duty MPP / gas filled capacitor unit, A/M Switch, ON Delay timer,ON / OFF Push button, ON, TRIP, Auto and Manual Indication lamp etc. as per Tender SLDand Specification 2.1 25 KVAR FEEDER: 4 NOS2.2 20 KVAR FEEDER: 1 NO2.3 5 KVAR FEEDER: 2 NOS2.4 2 KVAR FEEDER: 2 NOS2.5 1 KVAR FEEDER: 1 NO2.6.Two nos. Vacant feeder suitable for 1-25KVAr and 1-20KVAr to be provided.NOTE: 1. cooling/exhaust fan : Heavy duty 8` Metalic Housing and Metal Impeller / Blade / Vanes of Minimum2nos. or higher as required at the top of the panel with canopy/hood.2. For Capacitors of rating = 5 KVAr only, All types viz. APP/MPP/Gas Filled are acceptable. |
| 10 | `SITC of 400V, 3Ph 4 wire, closed loop compensation, min. 150A Active harmonics filter (AHF) with MCCB and fast acting semi conductor fuse protection, CT of Class 1 or better with 15 VA, Touch screen display, Alarms for fault conditions, floor mounted, expandable as per site requirement and complete in all respects as per Specification / IS/IEC to maintain harmonic levels as per latest IEEE 519 standards.Note:- Above mentioned ratings are min rating for AHF panel and contractor to provide higher rating AHF panel if required as per actual calculation of the vendor/ OEM. |
| 11 | `SITC of Lighting Distribution Board (LDB) as under:SITC of 3 Phase 4 Wire 4P, double door Prewired LDB each for Indoor Lighting and Outdoor Lighting Suitable to house :Incoming: 32A FP, ELMCB (30mA)Outgoing: 20A SP MCB (9 nos.) and 16A SP MCB (9 nos.) |
| 12 | SITC of Power Distribution Board (PDB) as under:(1no. PDB at PH)3 Phase 4 Wire TPN, 10 way Pre-wired-MOG / MOV PDB for Auxiliary accessories Load power supply (6 nos. MOV At Pump Delivery, 1 no. MOV On Header, For 1 no. WR-DB At P.H. , 1no. for EOT with ECH at screen, Aux. load and Rest spare)Incoming: 63A 4P, MCB `C` CurveOutgoing: 10 nos. 32A 4P MCB `C` Curve |
| 13 | LOW VOLTAGE (LT) CABLES Supply, laying , testing and commissioning of 1.1 kV, A2XFY(X)/2XWY(X) XLPE insulated (IS 7098) AL / Cu stranded conductor, Extruded inner sheath cables as per specification and IS. The cable when laid outside the building shall be laid underground in trench with brick and sand protection/in DWC pipes as per specified method and shall be laid in prepared trench/ on cable tray when laid inside the building.SITC of 3.5C x 240 sq. mm. A2XFY Cable (3 runs each for Transformer-1 and 2 to PMCC panel incomer-1 and2, 3 runs for DG to AMF panel, 3 runs for AMF panel to PMCC panel, 1 run each for PMCC panel to APFC-1 and APFC-2 Panel) |
| 14 | LOW VOLTAGE (LT) CABLES SITC of 3.5C x 120 sq. mm. A2XFY Cable (1 run each for PMCC Panel to AHF-1 and 2 Panel, 1 run each for PMCC Panel to 6 nos. 75kW 75kW VFD Panel) |
| 15 | LOW VOLTAGE (LT) CABLES SITC of 3C x 120 sq. mm. A2XFY Cable (1 run each for 75kW VFD Panel to 6 nos. 75kW VT Pump Motor) |
| 16 | LOW VOLTAGE (LT) CABLES SITC of 4C x 10 sq. mm. A2XFY Cable (1no. for Chlorination panel, 2 nos. for PDB, 1 no. for EOT Crane for PH , 1no. EOT crane for Chlorination Room, 2nos. for dewatering pump panel, 1no. for portable dewatering pump panel, 1no. For FDF Panel) |
| 17 | LOW VOLTAGE (LT) CABLES SITC of 4C x 6 sq. mm. A2XFY Cable (For 1 no. Indoor LDB, 1 no. for Outdoor LDB, 1 no. for EOT Crane at Pump House, 1no. EOT with ECH at screen, 1 no. WR-DB at Pump House) |
| 18 | LOW VOLTAGE (LT) CABLES SITC of 4C x 2.5 sq. mm. 2XWY(X) Cable (For 6 nos. MOV At Pump Delivery, 1 no. MOV On Header, 5 nos. MOG, 2 nos. for DG sensing and battery charging, 1 no. ICP/PLC Panel and for 6 nos. street light) |
| 19 | LOW VOLTAGE (LT) CABLES SITC of 2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (For 2 nos. Tr. Marshalling Box, 2 nos. APFC CT, 6nos. Space Heater) |
| 20 | LOW VOLTAGE (LT) CABLES SITC of 5C x 2.5 sq.mm. 2XWY(X) Cable |
| 21 | LOW VOLTAGE (LT) CABLES SITC of 10C x 2.5 sq.mm. 2XWY(X) Cable (2 Run Tr. to HT Panel control cable) |
| 22 | CABLE END TERMINATION AND CONNECTION:SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic lugs / sockets with necessary tools and equipment`s as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned below and as per specifications.1) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.2) The job also includes, if necessary, supply and fixing of extension busbar of same material on MCCB or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.(Cable termination qty. shall be as per site requirement)4C x 2.5 sq. mm. 2XWY(X) Cable (For 6 nos. MOV At Pump Delivery, 1 no. MOV On Header, 5 nos. MOG, 2 nos. for DG sensing and battery charging, 1 no. ICP/PLC Panel and for 6 nos. street light) |
| 23 | CABLE END TERMINATION AND CONNECTION:SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic lugs / sockets with necessary tools and equipment`s as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned below and as per specifications.1) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.2) The job also includes, if necessary, supply and fixing of extension busbar of same material on MCCB or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.(Cable termination qty. shall be as per site requirement)2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (For 2 nos. Tr. Marshalling Box, 2 nos. APFC CT, 6nos. Space Heater) |
| 24 | CABLE END TERMINATION AND CONNECTION:SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic lugs / sockets with necessary tools and equipment`s as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned below and as per specifications.1) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.2) The job also includes, if necessary, supply and fixing of extension busbar of same material on MCCB or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.(Cable termination qty. shall be as per site requirement) 5C x 2.5 sq.mm. 2XWY(X) Cable |
| 25 | CABLE END TERMINATION AND CONNECTION:SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic lugs / sockets with necessary tools and equipment`s as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned below and as per specifications.1) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.2) The job also includes, if necessary, supply and fixing of extension busbar of same material on MCCB or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.(Cable termination qty. shall be as per site requirement)10C x 2.5 sq.mm. 2XWY(X) Cable (2 Run Tr. to HT Panel control cable) |
| 26 | Cable Protection/ Covering in Trench: Cable Covering with second class bricks or cement tiles laid cover the cable (top) and also on both side with sand bedding/cusioning of 75mm.and covering of 150mm Layer of sand above cable (16 bricks per meter.) as per IS and Tender Drg/ Specification. (For HT/LT cable protection) complete in all respects as instructed by EIC. |
| 27 | INTERNAL WIRINGSITC of Mains and outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked flexible stranded copper conductor wires with medium class min. 25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to be run on surface / wall / ceiling with following sizes as mentioned below. The unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets, switch board, brass chromium / cadmium plated machine screws, phase and neutral wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as per tender specification / IS. (a) SITC of Mains wiring with 3 wire 1.5 sq.mm. |
| 28 | INTERNAL WIRINGSITC of Mains and outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked flexible stranded copper conductor wires with medium class min. 25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to be run on surface / wall / ceiling with following sizes as mentioned below. The unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets, switch board, brass chromium / cadmium plated machine screws, phase and neutral wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as per tender specification / IS. (b) SITC of Mains wiring with 3 wire 2.5 sq.mm as per tender specification and IS. |
| 29 | INTERNAL WIRINGSITC of Mains and outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked flexible stranded copper conductor wires with medium class min. 25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to be run on surface / wall / ceiling with following sizes as mentioned below. The unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets, switch board, brass chromium / cadmium plated machine screws, phase and neutral wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as per tender specification / IS. (c) SITC of Mains wiring with 4 wire 1.5 sq.mm as per tender specification and IS. |
| 30 | INTERNAL WIRINGSITC of Mains and outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked flexible stranded copper conductor wires with medium class min. 25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to be run on surface / wall / ceiling with following sizes as mentioned below. The unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets, switch board, brass chromium / cadmium plated machine screws, phase and neutral wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as per tender specification / IS. (d) SITC of Mains wiring with 4 wire 2.5 sq.mm as per tender specification and IS. |
| 31 | SITC of Point wiring for Light / fan / Bell / Primary Point with 2nos. 1.5 sq. mm and earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multistrand copper wires , pipe to be erected concealed in flushed on wall / ceiling, complete with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on metal / PVC Box covered with 3 mm thick PC (Polycarbonate) / Acrylic sheet with necessary lamp holder / ceiling Rose / H. D. connector as directed with medium class Rigid PVC pipe and accessories. |
| 32 | SITC of 6A independent Plug with 2nos. 1.5 sq.mm Cu. Mains size wiring and earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe and accessories to be erected on wall / ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. (1 no. at HT Room, 4 nos. at LT Room cum Pump House) |
| 33 | SITC of 6/16A independent Plug with 2nos. 4 sq.mm Cu. Mains size wiring and earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe and accessories to be erected on wall / ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet.(1 no. at HT Room, 4 nos. at LT Room cum Pump House) |
| 34 | SITC of Single Phase 20A 3 Pin Matal clad Industrial Type Socket with plug top and 20A SPMCB, suitable for flush mounting, in 16 SWG MS box of suitable size and covered with 3 mm thick electrical grade hylam sheet or eqivalent ISI marked Electrical grade bakelite sheet and earthing with 2.5 sq.mm insulated copper wire run inside the conduit including interconnections etc. complete as required. (1 no. at HT Room, 4 nos. at LT Room cum Pump House) |
| 35 | SITC of One 300/380 mm dia. Ex fan 16A independent Plug point near Ex. Fan with 2nos. 4 sq.mm Cu. Mains size wiring and earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe and accessories to be erected on wall / ceiling, complete with ISI marked 3Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. Plug point shall be near Ex.Fan.(5 nos. LT Room cum Pump House) |
| 36 | SITC of 380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan. (2 nos. L.T Room cum Pump House) |
| 37 | SITC of 300mm sweep 960 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan. |
| 38 | LED LIGHT FIXTURES and LIGHTING:SITC of Indoor wall mounting 20Watt or up to 25% higher wattage LED 4 feet Tube Light indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. and corrosion resistance with diffuser and/or Polycarbonate optics with company mark/name 120 to 300 V,Power Factor more than 0.9, THD ( 10 %,CCT 4000 K to 6500K, Uniformity ratio )0.7,Luminaire efficacy) 85 lumens/watt ,LED driver efficiency ) 85 %(Each fitting required LM-79 and LM-80 Certificates)Tube Light with integral / non-integral driver, Surge-4KV,IP-20, 4 feet, Cat-III(For 3 nos. Client HT Room, 17 nos. LT Room cum Pump House) |
| 39 | LED LIGHT FIXTURES and LIGHTING:SITC of Indoor wall mounting 20Watt or up to 25% higher wattage LED 4 feet Tube Light indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. and corrosion resistance with diffuser and/or Polycarbonate optics with company mark/name 120 to 300 V,Power Factor more than 0.9, THD ( 10 %,CCT 4000 K to 6500K, Uniformity ratio )0.7,Luminaire efficacy) 85 lumens/watt ,LED driver efficiency ) 85 %(Each fitting required LM-79 and LM-80 Certificates)SITC of 7 watts LED Lamps integral type,cool white with PC diffuser suitable for B22 LAMP holder (For 1no. HT Room, 4 nos. LT Room cum Pump House). |
| 40 | LED LIGHT FIXTURES and LIGHTING:SITC of 40W LED Surface / Wall mounted LED Flood Light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD ( 20 %, CCT 5000 K to 5700K,Uniformity ratio )0.45, Luminaries efficacy) 85 lumens/watt . LED driver efficiency ) 85 %.( Each fittings required LM-79 and LM-80 certificates) (IP-65), Surge -4KV Cat-III For Indoor use: ( Pump House) |
| 41 | LED LIGHT FIXTURES and LIGHTING:SITC of `B` class galvanised iron pipe 32 mm outside dia 45 cms long duly welded on 20 cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or corner for mounting luminaire with necessary hardware materials duly painted for wall mounting indoor flood light fixtures on Wall of Buildings and post top lantern. |
| 42 | EXTERNAL LIGHTING (Flood LIGHT):SITC of 70W LED Wall mounted LED Flood Light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD ( 20 %, CCT 5000 K to 5700K,Uniformity ratio )0.45, Luminaries efficacy) 85 lumens/watt . LED driver efficiency ) 85 %.( Each fittings required LM-79 and LM-80 certificates) (IP-65), Surge -4KV Cat-III For Outdoor use: (area lighting) |
| 43 | EXTERNAL STREET LIGHTINGSITC of above 70W LED Street light fittings (Cat-III) with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 160 to 270 V, Power Factor more than 0.95, THD ( 10 %, CCT 3000 K to 5700K,Uniformity ratio )0.45, Luminaire efficacy)100 lumens/watt . LED driver efficiency ) 85 %, Each fittings required LM-79 and LM-80 certificates, street Light (IP-65), Surge -4KV, integral and light must have 440V line supply with over voltage protection. |
| 44 | DISEL GENERATOR SETSITC of AMF panel suitable for 500 KVA 3 phase, 415V, AC diesel generating sets complete scope as detailed below: Panel shall be Floor mounted, dust and vermin proof, indoor type Panel shall be consisting of suitable rating ACB / MCCB (As per Tender), Electronic AMF cum Synchronizing Logic relay (Nb2 or Equivalent) with minimum functions, 3Line Display MFM, digital voltmeter, Ammeter, Power factor, frequency, hour meter, Emergency Stop PB, CTs, with Indication, Alaram and Trip Annunciation, Selector switch, other accessories etc. as complete in all respect as required. |
| 45 | SAFETY ACCESSORIESSITC of following safety accessories complete with necessary fixing brackets, other accessories and tools etc. as required to complete the job.Supply and Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut and bolts grouted in wall complete. (For 1 no. DP, 2 nos. X`mer-1 and 2, 1 no. HT Room, 2 nos. for LT Room cum PH, 1 no. for DG set) |
| 46 | SAFETY ACCESSORIESSupplying of standard first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, guage bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, scissors, antiseptic solution (Savlon or similar) etc. (All above contents shall be of standard makes) (1 no. for HT Room, 1 no. for LT Room cum Pump House) |
| 47 | SAFETY ACCESSORIESSupply and fixing of 20 W LED lamp operated emergency light with maintenance free battery for 3 hours operation during mains power failure. |
| 48 | SAFETY ACCESSORIESSupply and laying of Synthetic Insulating Mat of Class - A of min. thickness 2mm as per IS:15652 and with good electrical insulation property for 1.1KV/3.3KV as per site requirement. (For LT Panel) |
| 49 | SAFETY ACCESSORIESProviding pair of rubber hand gloves ISI make suitable for working on 22 KV supply |
| 50 | SITC of LT PMCC Panel (50kA), compartmentalized, Floor mounted, operating height maximum 1800/1900 mm, Extensible on both ends, suitable for Manual and Auto operation -Local and through PLC/SCADA operation complete in all respects as per Tender:(1) INCOMER 1and2: FP, 630A, 50 KA MP EDO ACB LSIG with inbuilt RS 485 MODBUS communication with Digital Voltmeter with VSS, Ammeter with ASS, Resin Cast CT-Cl : 0.5,10VA, Digital MFM with RS 485 with 3 Line Display Cl. 0.5, TNC, A/M switch, Indicating lamps, Push bottons etc,. with electrical and mechanical interlocking between Incomers and buscoupler. (1.1) Surge protection device, 3P plus N, Type 2 for lightning/surge protection. Load sensing CT in Incomer and Busbar for APFC panel, Cl.-0.5. Constant voltage/control voltage transformer 1500VA, 415V/230V AC, with tapping plus /-5% in steps of 2.5%, 32A DP MCB and 25A Power contactor.(2) BUS-COUPLER: One no. FP 630A ACB (same as per Incomer) (2.1) 800A TPN, EC grade AL Main busbars. (Busbars size as per Minimum current density 0.8A/Sq.mm) (3) DG INCOMER : FP, 800A, 50 KA MP EDO ACB LSIG with inbuilt RS 485 MODBUS communication (Meters, Indication and PB same as per Incomer) with electrical and mechanical interlocking between Mains and DG set. (4) TRANSFORMER FIXED COMPENSATION FEEDER (12 kVAR): 2 Sets: Each comprising of 32A FP Thermal Magnetic MCCB, Ind. Lamp, with Capacitor duty contactor, ON Delay timer, individual MCCB/MCB.(5) 135 KVAR APFC POWER FEEDER: 2 NOS Feeder comprising of 320A TPN TM MCCB, 50kA, Digital Ammeter with ASS, CT, Indicating lamps, etc.complete in all respects.(6) 150A AHF POWER FEEDER: 2 NOS Feeder comprising of 200A TPN TM MCCB, 50kA, MFM with RS-485, CT, Indicating lamps, etc. complete in all respects.(7) 75KW Stand Alone VFD Panel POWER FEEDER: 6 NOS Feeder comprising of 200A TPN TM MCCB, 50kA, MFM with RS-485, CT, Indicating lamps, etc. complete in all respects.(8) 63A TPN TM MCCB FEEDER : 10 NOS. (1no. for Chlorination panel, 2 nos. for PDB, 1 no. for EOT Crane, 2nos. for dewatering pump panel, 1no. for portable dewatering pump panel, 1no. FDF Panel, 2nos. Spare)Each feeder comprising of 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp etc. (9) 32A TPN TM MCCB FEEDER : 2 NOS. (1no. for EOT crane @ Chlorination Room, 1no. Spare)Each feeder comprising of 32A TPN Thermal Magnetic (TM) MCCB, with indicating lamp etc.(10) 63A TPN TM MCCB FEEDER FOR ALL MCB FEEDERS: 2 SETS: Incomer: 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp etc. (a) 6 nos. 32A `C` curve 4P MCB feeders (for 2nos. DG Charging and Sensing 1 no. Ind LDB, 1 no. for ICP/PLC Panel, 2 nos. Spare) (b) 1 no. 32A `C` curve 4P MCB with Time switch,32A contactor 4P,ON lamp feeders (for Outdoor LDB)(c) 4 nos. 16A DP MCB feeders (For HT Panel, 2 nos. for X`mer marshaling box, 1 no. Spare)(11) Multiplication relay as required for dry run protection of pumps. |
| 51 | INSTRUMENTATION WORKPRESSURE MEASURING SYSTEMSupply, installation, testing and commissioning of Bourdon Type Pressure Guage having 150 mm dial with isolation ball valve in SS 316, necessary fittings/accessories in SS 316 (3 way 2 valve manifold, nipples, coupling etc.) complete in all respects and as per specification. Range : 0 - 4 Kg/cm2 (at each pump delivery side) |
| 52 | PRESSURE MEASURING SYSTEMSupply, installation, testing and commissioning of Pressure Transmitter with local display all mounting accessories,three way manifold, hardware, etc. Range : 0 - 4 Kg/cm2 (at each pump delivery side) |
| 53 | LEVEL MEASURING SYSTEMSupply, installation, testing and commissioning of Remote type Ultrasonic Level Transmitter along with 10 meter cable between Sensor and Transmitter, all mounting accessories, hardware, etc. complete in all respects and as per specification and having following measurement ranges for liquid (Sewage) application: Meas. Range: upto 10 mtr. (at Suction Pit) |
| 54 | ELECTRO MAGNETIC FLOWMETER Supply, installation, testing and commissioning of Full Bore Electromagnetic flow meter comprising of IP-68 Sensor, IP-66 remote type transmitter with 20 m cable between sensor and transmitter along with all mounting accessories, Weather proof enclosure for transmitter, hardware, mounting stand, etc. as per specification and to complete the work in all respect as per site condition necessary connection with pipe and shall have following size.Meter size: 900 mm NB (at Pump Common Discharge Header)Pipe Size : 900 mm NB |
| 55 | Supply, installation, testing and commissioning of TSS analyser with Sensor, Transmitter, Immersion/ Flow through Assembly, Mounting hardware, Mounting hardware, etc, at Commend Inlet of FDF |
| 56 | PLC BASED INSTRUMENT CONTROL PANEL ( EXCEPT FDF SYTEM)Supply, Installation, Testing and Commissioning of PLC Based Instrument control Panel with Local SCADA system comprising of min. 24” PC Console with A4 size laser jet printer for report / alarm printing, SCADA run time 25 display/ Equvalent Tag software licence, 4G/ Latest GSM/GPRS modem for remote data transmission to Central SCADA of Client/PMC, Communication port for MFM, Etherenet Switch, etc. Instrument Control Panel `(PLC Enclosure / Panel ) with necessary PLC based logic and wiring , Min. 2 kVA UPS (with 60 min backup ), etc. complete in all respects and as per specs PLC having minimum I/O count of 60DI / 36DO /26AI / 8AO. |
| 57 | INSTRUMENT CABLE and ACCESSORIESSupply, Laying, Installation, Connection, Termination, Testing and Commissioning of Instrument Cables and accessores as per specs. The unit rate shall include. (a) Supply, loading and unloading of the cable at site from store. (b) Shifitng of cable from site store to place of installation. (c) Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. (d) Excavation, back filling and levelling of ground alongwith laying of fine sand, protection bricks and other necessary civil material for laying cables outside the building. (e)Testing and submission of sketches and reports of all the cables laid.POWER CABLE3C X 1.5sq.mm. |
| 58 | INSTRUMENT CABLE and ACCESSORIESSupply, Laying, Installation, Connection, Termination, Testing and Commissioning of Instrument Cables and accessores as per specs. The unit rate shall include. (a) Supply, loading and unloading of the cable at site from store. (b) Shifitng of cable from site store to place of installation. (c) Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. (d) Excavation, back filling and levelling of ground alongwith laying of fine sand, protection bricks and other necessary civil material for laying cables outside the building. (e)Testing and submission of sketches and reports of all the cables laid.SIGNAL CABLE1P X 1.0sq.mm. |
| 59 | INSTRUMENT CABLE and ACCESSORIESSupply, Laying, Installation, Connection, Termination, Testing and Commissioning of Instrument Cables and accessores as per specs. The unit rate shall include. (a) Supply, loading and unloading of the cable at site from store. (b) Shifitng of cable from site store to place of installation. (c) Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. (d) Excavation, back filling and levelling of ground alongwith laying of fine sand, protection bricks and other necessary civil material for laying cables outside the building. (e)Testing and submission of sketches and reports of all the cables laid.CONTROL CABLE 12C X 1.0sq.mm. |
| 60 | INSTRUMENT CABLE TRAY G.I. Perorated type cable tray shall be made out of galvanized mild steel sheets of 2 mm thickness with required asccessories . All material shall be Hot dip galvanised as per IS 2629 ( as mentioned in specification and tray hardware shall be in GI.450 X 25 mm - Perforated type |
| 61 | INSTRUMENT CABLE TRAY G.I. Perorated type cable tray shall be made out of galvanized mild steel sheets of 2 mm thickness with required asccessories . All material shall be Hot dip galvanised as per IS 2629 ( as mentioned in specification and tray hardware shall be in GI.100 X 25 mm - Perforated type |
| 62 | CABLE END TERMINATION and CONNECTION : Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as specified in specifications and IS complete in all respects. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh as applicable. POWER CABLE3C X 1.5sq.mm |
| 63 | CABLE END TERMINATION and CONNECTION : Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as specified in specifications and IS complete in all respects. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh as applicable. SIGNAL CABLE 1P X 1.0sq.mm. |
| 64 | CABLE END TERMINATION and CONNECTION : Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as specified in specifications and IS complete in all respects. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh as applicable. CONTROL CABLE12C X 1.0sq.mm |
| 65 | HORIZONTAL SPLIT CASE CENTRIFUGAL PUMP SET (PUMP-MOTOR ASSEMBLY SET)Supply, Installation, Testing and Commissioning (SITC) of horizontal mounted, side suction and side delivery type Horizontal Split Casing Centrifugal Pump having CI Casing, CF8M impeller and wear rings, SS410 Shaft and shaft sleeves, gland packed, SS-304 Suction Strainer with suitable size opening as reco. by pump vendor, and suitable to couple with Induction Motor.SITC of approved make, energy efficient, Efficiency Class-IE3, Horizontal Foot mounted, solid shaft, squirrel case, Induction Motor as per IS 12615: 2018 of rating min. as mention below or higher as per pump manufacturer recommendation, VFD operated motors shall have vacuum impregnated, double insulation winding with Class H insulation and with temperature rise limited to class F of inverter duty, 3 Phase, 415V, 50Hz., AC supply, max. synchronous speed as mentioned below, with Terminal box and auxillary terminal for Space Heater.The scope also include all required accessories viz. CI/MSEP drain rim type base plate base frame, Flex. coupling, coupling guard, foundation bolts, min. 25 mm dia. G.I. Class-B drain pipe up to drain channel, etc. complete as per IS/IEC, Tender Drawings and Specification and also including in scope any other parts / accessories / fittings as required to complete the work in all respects and satisfactory operation of pump set.Pump Capacity: 750 m3/hr. (4W plus 2S), Head: 20 m, Nominal Speed: 1500 RPM, Minimum Acceptable Pump Efficiency at Duty Point: 80 % and Motor Rating: Minimum 75 kW (or higher as recommended by pump manufacturer). |
| 66 | SITC of CI/DI Manually Handwheel operated Double Flanged, Sluice Valve confirming to IS 14846, PN 1.0 of following sizes with SS 304 seat rings with hot dipped galvanised hardwares, bolts, nuts and washers etc. as per IS and Specification and complete the work in all respects.Size: 100 mm NB (at Drain pump delivery) |
| 67 | SITC of CI/DI Manually Handwheel operated Double Flanged, Sluice Valve confirming to IS 14846, PN 1.0 of following sizes with SS 304 seat rings with hot dipped galvanised hardwares, bolts, nuts and washers etc. as per IS and Specification and complete the work in all respects.Size : 150 mm NB (at Header drain line) |
| 68 | SITC of CI/DI Manually Gear operated Double Flanged, Sluice Valve confirming to IS 14846, PN 1.0 of following sizes with SS 304 seat rings with hot dipped galvanised hardwares, bolts, nuts and washers etc. as per IS and Specification and complete the work in all respects.Size: 450 mm NB (at suction line of each HSCF Pumpset) |
| 69 | SITC of CI/DI Electric Actuator operated Double Flanged, Sluice Valve confirming to IS 14846, PN 1.0 of following sizeswith hot dipped galvanised hardwares, bolts, nuts and washers etc. as per IS and Specification and complete the work in all respects.Ele. Actuator shall be provide with Position transmitter (4-20mA output)Size: 400 mm NB (at delivery line of each HSCF Pumpset) |
| 70 | SITC of Non slam, flanged, Single Door type Non Return Valve conforming to IS 5312 (Part-1), PN 1.0, having CI / DI body and door, CF8M seat rings alongwith all necessary hardwares as per specifications and complete in all respect.Size: 400 mm NB |
| 71 | `SITC of CI / DI double flanged Dual Plate Check Valve conforming to API 594, Class 125 with Cast Steel dual door, hinge pin and stop pin of SS 410, springs of AISI 304 and seat of SS 304, along with all required accessories, gaskets and hardwares, etc. and as per specification and complete the work in all respects.Size : 900 mm NB |
| 72 | SITC of Electric Actuator operated Horizontal shaft CI/DI double flanged Butterfly Valve, conforming to IS 13095 / BS EN 593, PN 1.0 with SS 304 renewable seat ring, indicator, gear box with bolts, nuts and washers, gaskets, etc. as per specifications. Ele. Actuator shall be provide with Position transmitter (4-20mA output)Size : 900 mm NB (At common Header) |
| 73 | SITC of CI/ DI Temper proof Flanged Air Valve with Isolation Sluice Valve as per AWWA / IS 14845 PN-1.0 and IS-14846 PN-1.0 respectively with SS304 float, gun metal nozzle, complete hardware`s, bolts, nuts and washers, gaskets etc. complete as per IS and Specification.Size : 150 mm NB (At common Header) |
| 74 | SITC of Flange ends Expansion Bellow (PN 1.0) as per EJMA standards and as per specs. and complete in all respect.Size : 450 mm NB X 300 mm L (at suction line of each HSCF Pump setS) |
| 75 | `SITC of Flange ends Expansion Bellow (PN 1.0) as per EJMA standards and as per specs. and complete in all respect.Size : 400 mm NB X 300 mm L (at delivery line of each HSCF Pumpset) |
| 76 | `SITC of Flange ends Expansion Bellow (PN 1.0) as per EJMA standards and as per specs. and complete in all respect.Size : 900 mm NB X 300 mm L (at common header line) |
| 77 | `SITC of Single Girder type E.O.T. crane with electrically operated hoist, class II duty, geared travelling trolly with lift as specified here below complete with long travel rail track (40 sq.mm. bar), moving or cross girder, all three motions electrically operated by suitable rating motor IP54, control panel, and down pendant control block, brake, safety device, cables from motor to starter panel and other required accessoaries and manufactured and tested as per IS-807, IS-3938 and IS-3177, class-II, complete as per IS and Specifications.Capacity: min. 3 Ton,Span: approx 7.0 m (or as per site)Lift: 10.0 m (or as per site)Bay length: approx. 32.25 m (or as per site)Note: Minimum as specified capacity or higher as per requirement such that EOT crane capacity is min.1.25 times of the Subm. pump set or single heaviest component to be lifted within pump house. |
| 78 | `SITC of Single Girder type E.O.T. crane with electrically operated hoist, class II duty, geared travelling trolly with lift as specified here below complete with long travel rail track (40 sq.mm. bar), moving or cross girder, all three motions electrically operated by suitable rating motor IP54, control panel, and down pendant control block, brake, safety device, cables from motor to starter panel and other required accessoaries and manufactured and tested as per IS-807, IS-3938 and IS-3177, class-II, complete as per IS and Specifications.Capacity: 3 Ton,Span: approx 6.0 m (or as per site)Lift: 5.5.0 m (or as per site)Bay length: approx. 20.0 m (or as per site)Note: Minimum as specified capacity or higher as per requirement such that EOT crane capacity is min.1.25 times of the Subm. pump set or single heaviest component to be lifted within pump house. |
| 79 | MONORAIL EOT WITH ELECTRIC CHAIN HOISTSITC of Electrically Operated Chain Hoist and Electrically operated Trolley, suitable to operate on Mono Rail Girder having motorised motion, mfg. as per IS:6547-1972-Class-II and IS-3177- Class-II, complete with brake, chain-gear, motors, safety device, pendant push button, starter panel, cables from motor to starter panel and all other required accessories like limit switches, power supply system (Fastoon cable type), fasteners, epoxy painting, etc. tested for over load as per IS and as per specs, complete in all respect.Capacity : min. 1.0 Ton.Lift : 10.00 m as mini. or as per site req.Bay Length : 10.0 m or as per site req.(w/o MONORAIL GIRDER and MS supporting structure) |
| 80 | SITC of Box Type Manual mesh Screen having following size, made of SS 304 material having round bars of size 9.0 mm dia with clear bar opening as specified here below, suitably welded in outer frame of equal Leg SS angle of size 20 mm x 20 mm x 6 mm thick or higher, with intermediate support at required locations, complete as per specs. and shall also including followings: The screen shall be with SS perforated Screening Material Collection Box at bottom end of Screen having size as specified, fabricated from 3 mm thk SS sheet, screen shall be suitable to slide complete screen through rollers between existing guide passage of MCP 400, embedded/ fixed in wall on both sides of RCC wall up to top of chamber with all necessary hardware, SS nuts, bolts and wahsers, sacrificial Brass lugs on sides, min. two lifting lugs/hooks and SS lifting chain having intermediate link/chain of 100 mm dia. at every 1.5 m distance with shackle, etc. complete in all respects and provided with 1 set of cleaning rake with each screen, complete as per specification and complete in all respect.Screen Size: 1500 mm (W-or actual chamber width as per site ) x 2000 mm (H) x 300 mm (D) Box Size: 1500 mm (W-or actual screen width) x 300 mm (H) x 300 mm (D)Opening: 50 mm x 50 mm sq. opening Note : 1. Screen suitable for 1600 mm wide screen chamber or to suit site requirement. |
| 81 | SLUICE GATESITC of Electric Actuator operated C.I. Sluice Gate conforming to AWWA C 501 or IS : 13349 - 1992 Class - 1 with rising spindle, single faced, wall thimble mounted, handwheel, flange back frame, head stock, Spindle with supports brackets having length as specified or to suit site condition, suitable for seating as well as unseating water head, complete in all respect.Gate Size : 900 mm X 900 mm - approx. 5 m spindle length - Flush bottom or suitable closing. (02 Nos. at Sump inlet, 01 No. at sump compartment wall, 02 Nos. at Suction pit inlet) |
| 82 | FIBER DISC FILTERDisc filter shall comprise of Twenty-Two (22) high strength and separable discs (proposed by manufacturer), each of which consists of total twenty four (24) filter panels on both sides (12 filter panels/ each side) per unit. Each filter disc shall be subdivided into smaller sections to constitute a prefab disc frame (module) so as to ensure easy replacement and maintenance. In case of replacement of Fiber media, the left and right of the fiber media can be replaced quickly without Each disc shall be mounted on the center drum by strap band (steel band) for the exact roundness and it shall not be fixed by Stud bolts. The additional sealing material is not needed for assembling of filter panel to segment as the fiber media itself shall act as the sealing material. When Fiber media is mounted in the segment (Disc frame), the sealing shall be maintained by one or more fixing device which has slope on both sides of segment. Fiber media shall envelop some parts of backside of filter frame and the several springs shall be used to fix the fiber media. The drum shall be round type and shall have enough area in order to discharge the treated water without trouble.The material of the fiber media shall be polyester: the filter frame that fixes the fiber media, the disc frame and the cover shall be ABS resin. |
| 83 | SLUICE GATESITC of Electric Actuator operated C.I. Sluice Gate conforming to AWWA C 501 or IS : 13349 - 1992 Class - 1 with rising spindle, single faced, wall thimble mounted, handwheel, flange back frame, head stock, Spindle with supports brackets having length as specified or to suit site condition, suitable for seating as well as unseating water head, complete in all respect.Gate Size : 1000 mm X 1500 mm - approx. 2.5 m spindle length - Flush bottom or suitable closing. (03 Nos. at FDF inlet, 03 No. for FDF Outlet and 01 No. at FDF Bypass) |
| 84 | CHLORINATION SYSTEMSITC of Floor mounted, FRP cabinet type, Vacuum operated Chlorination plants complete in all respects with required piping, fitting, valves, safety and testing kit, etc. Complete system combining the Two plants complete in all respect as per IS and as per specification.Capacity: 20 kg/hr. (2 Nos.: 1 W plus 1S)Each plant shall include the followings:(1) 1 No. Submersible monoblock Pump motor set with continuous Cable from pump to starter panel without any Joint with proper conduit piping and clamping. (2) 1 No. Diffusers (3) 1 No. Ejector (4) 1 No.Chlorinator, (5) 1 No. Vacuum Regulators (6) 1 No. Strainer (7) 1 No. NRV on solution line (8) 1 No. Non Return Valve on Booster Pump del. line (9) 6 Nos.Yoke clamp (1 No. for each tonner) (10) 1 No. Pressure Gauge with require piping and isolation valve for booster pump (11) 1 No. Chlorine Gauge at Cl2 manifold with isolation valve (12) 1 Lot of piping, fittings, valves and instruments (13) Total 5 nos. or higher as required Isolation valve on gas manifold (14) Vacuum Gauge (15) MS support of 50 mm x 50 mm x 4 mm thk. (16.) 6 Nos. Filled Chlorine Tonner (17.) Lifting Beam (18.) Crane Type weigh Scale (19.) Roller support for 6 Nos. Chlorine TonnerNotes: (1) 1 no. Gas filter shall be provided per manifold.(2) 1 - lot inter connecting piping of identical pipe size of Cl2 booster pumps delivery line with required no. isolation valves.(3) 1 No. Chlorine Analyzer (0-5 mg/l) shall be provided(4) Any other as required to complete the work in all respects.Supply of safety kit and testing as specified in the specifications.(1) 1 Set Chloroscope,(2) 1 set. Air breathing apparatus for 45 min as per IS,(3) 1 set. Emergency tool kit,(4) 1 No. Amonia Torch, etc.(5) 2 Nos. PVC Cabinet(6) 1 No. Emergency Showers with eye wash(7) 4 Nos. Safety Clothing(8) 1 Set Erection and Maintenance toolsAUTOMATIC CHLORINE LEAK ABSORPTION/DISSOLVING SYSTEM(CHLORINE SCRUBBER SYSTEM)SITC of Automatic Chlorine Leak Absorption System for (900 kg) tonner for chlorination system comprising of :(1) 6 Nos. FRP Hood for 900 kg Cl2 Tonnner(2) 2 Nos. (1W plus 1S) CF Air Blower with electric motor(3) 2 Nos. (1W plus 1S) Caustic Circulating Pump with electric motor(4) 3 Nos. Chlorine leak detector(5) 1 Lot Flex. PVC ducting line, (All misc. items such as Ball valve for flush line / Water Line / suction and delivery of pump / drain line, NRV and Strainer for Pump – PP / UPVC)(6) 1 Lot uPVC SCH 40- Diffuser,(7) 1 Lot- MCC cum PLC with HMI Based Control panel consisting of minimum 32A, 4Pole MCCB for incoming power supply, starter for CF Blower, Caustic Circulation pumps, Booster Pumps as per type-2 cordination chart etc. complete in all respect.(8) 1 Lot- Interconnecting Electrical and Instrument Power, control and other required cables, cable tray, earthing etc with required accessories to complete the system in all respect.(9) 1 No. Pack Column type Absorption Tower MOC : PP plus FRP (Scrubber)(10) 1 No. Caustic solution storage tank including Tank level gauge with ISV and tank level switch for low alarm.(11) Liquid Caustic – First filling of 20% strength for scrubber system(12) 1 Lot Hadware, jointing and misc. items etc.(13) As per Specification and any other as required to complete the work in all respects. |
| 85 | Providing and supply and erection of ISI mark DI D/F butterfly valves as per 14846 latest edition of following class and diameter, including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to departmental stores, stacking, etc. Complete. PN-1 with ISI Mark 900 mm sluice valve |
| 86 | Providing and supply and erection of ISI mark DI D/F butterfly valves as per 14846 latest edition of following class and diameter, including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to departmental stores, stacking, etc. Complete. PN-1 with gear operated with ISI Mark 500 mm dia sluice valve. |
| 87 | Miscellaneous work-for shifting of existing infrastructure, water line/drainage line/electrical cable/other cables,etc. on the route during the execution work. |
| 88 | Horizontal Directional Drilling for steel ducts/pipes, installation of steel product pipe by HDD method, including preparing and setting up the plant and equipment, preparing new work, material, installing new pipe, work and commissioning system or making the system ready for commissioning by HDD operation, including all related civil and mechanical works like excavation, shoring/strutting, etc, drilling, stringing, reaming, and pulling back the new pipe work on the designed Bore path alignment, proper disposal of drilling fluid and backfill of site after completion of all inclusive as per IndSTT 101–2018 code of practice.fOR ROAD CROSSING STEEL CASING PIPE OF 1200MM DIA (id) 12 mm thick |
| 89 | Providing an erecting 1.5 m high temporary barricading at side, each panel of size 2.5 m x 1.5 m made of 40 x 40 x 6 MM angle iron or 50 x 50 x3 MM Hollow MS TUBE Posts/horizontal members/bracings covered with 1.6 3MM thick MS sheet, the sheet shall be fixed with 30 x 5mm MS flat by suitable welding riveting. The panel shall be made so that the gap of 50 cm above ground is available making overall height as 2.5 m MS channel ISLC 75 @ 5.70 Kg per metre, 50 cm long shall be provided at the bottom having oval shaped holes of size 50 x 25MM at both ends, the barricading provided shall be retained in position at site continuously i/c shifting a barricading from one location to another location as many times as required during execution of entire work till its completion. rate include maintenance for damages, painting, all incidentals, labour, materials, equipments and works required to execute the job, the barricading shall not be removed without prior approval of engineer in charge. The work shall be executed as per drawing direction of engineer in charge, which includes writing and painting arrangement for traffic diversion such as traffic signals during construction at sight for day and night glow lamps, reflective signs, marking, flags, caution tape as directed by engineering in charge.for 10 times and 2m height.DSR2023 |
| 90 | OandM cost including manpower,spares and chemicals excluding the cost of power for 1st year. |
| 91 | OandM cost including manpower,spares and chemicals excluding the cost of power for 2nd year. |
| 92 | OandM cost including manpower,spares and chemicals excluding the cost of power for 3rd year |
| 93 | OandM cost including manpower,spares and chemicals excluding the cost of power for 4th year. |
| 94 | OandM cost including manpower,spares and chemicals excluding the cost of power for 5th year |
| 95 | OandM cost including manpower,spares and chemicals excluding the cost of power for 6th year |
| 96 | OandM cost including manpower,spares and chemicals excluding the cost of power for 7th year |
| 97 | OandM cost including manpower,spares and chemicals excluding the cost of power for 8th year |
| 98 | OandM cost including manpower,spares and chemicals excluding the cost of power for 9th year |
| 99 | OandM cost including manpower,spares and chemicals excluding the cost of power for 10th year |
| 100 | OandM cost including manpower,spares and chemicals excluding the cost of power for 11th year |
| 101 | OandM cost including manpower,spares and chemicals excluding the cost of power for 12th year |
| 102 | OandM cost including manpower,spares and chemicals excluding the cost of power for 13th year |
| 103 | OandM cost including manpower,spares and chemicals excluding the cost of power for 14th year |
| 104 | OandM cost including manpower,spares and chemicals excluding the cost of power for 15th year |
| 105 | Trial run,testing and commissioning Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy