| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 2 | Provision for taking out iron jail from existing dwarf wall with proper care and store the iron mesh jail in store room properly including all material T&P etc. complete. ( Iron jail size 2.00 x 1.50) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge : All kinds of soil |
| 4 | Providing and laying in position base concrete for foundation footing in 1:3:6 (1 Cement : 3 coarse sand zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Centering and shuttering including strutting, propping etc. Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Mild steel and Medium Tensile steel bars |
| 12 | Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Finishing with deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications two or more coats applied on walls @ 1.25 ltr/ 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm |
| 15 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 16 | Provision for providing and fixing existing MS Grill railing after the raising of wall height, fixed with cement concrete in 1:2:4 cement concrete & with the help of scaffolding pipe and narial rope making in proper alignment including all T&P article etc., complete. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 18 | Providing & laying 12 mm cement plaster of mix cement mortar 1:4 (1 cement : 4 fine sand) including supply of all materials labour T&P etc. required for proper completion of work. |
| 19 | Providing and fixing MS grill size 2.00m x 1.60m with 50 x 50 x 5mm size MS angle and16 mm square bar including cutting, hoisting, fixing in position and making bhala at top of each 16mm square bar with supply of all T&P etc required for proper completion of work. |
| 20 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 21 | Provision for fitting & fixing of stone benches as per size top platform 1 no x 1.50 m x 0.60m x 0.15m and vertical base 2 no x 0.50m x 0.20m x 0.40 m including finishing and fixing in concrete base with supply of all materials labour T&P etc. complete. |
| 22 | Provision for fixing of M.S. gate with size 50x50x5 mm M.S. angle & 16 mm square bar including all cutting, fixing and bending etc. required for completion of work. Usage/Application Water Cooling Brand Aqua soft Type Cold Cooling Capacity120 LPH Warranty1 Year Body Material Stainless Steel Number Of Taps2 Weight150 kg Dispenser Single Dispenser Total Power1.5 kW Coin Operated Rs. 1,2,5,10 Dispensing300 ml,500 ml,1 ltr,2 ltr,5 ltr to 20 ltr Dimension 6.5 x 3.5 x 3.5 feet Please Enable Macros to View BoQ information |