| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge : All kinds of soil |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Centering and shuttering including strutting, propping etc. Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars. |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Mild steel and Medium Tensile steel bars |
| 14 | Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Providing & laying 12 mm cement plaster of mix. Cement mortar 1:4 (1cement: 4 fine sand). Including supply of all materials labour T.& P. etc., required for proper completion of work. |
| 18 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In charge |
| 19 | Provision for electrification including all fixtures with material labour etc complete.(all Items with ISI mark ) rate including GST |
| 20 | Provision for plumbing fitting with all fixtures as per detailed item / material with labour charfe approved from the circle office before execution of work complete. (detail item sanction should be obtain before execution of work ) |
| 21 | Provision for drainage supply fitting with all fixtures as per detailed item/ material with labour charge approved from the circle office before execution of work complete (details item sanction should be obtain before execution of work. |
| 22 | Providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building / structure , up to 25 meter height , above ground level , including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube , placed 1.5 meter center to center , horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and /or applying chemical and removing it thereafter . the scaffolding system shall be stiffened with bracings , runners connection with the building etc, wherever required if feasible for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in charge . |
| 23 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40 x 40 x 6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer . |
| 24 | Providing and fixing double glazed hermetically sealed glazing in aluminum windows, ventilators and partition etc. with 6 mm thick clear float glass both side , having 12 mm air gap, including providing EPDM gasket, perforated aluminum spacers, desiccants, sealant ( both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer - in - charge complete . |
| 25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 26 | Finishing with deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications two or more coats applied on walls @ 1.25 ltr/ 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm |
| 27 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 28 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 31 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with |
| 32 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm |
| 33 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws , 35 mm thick shutters, with ISI marked Stainless steel butt hinges bright finished of required size, Second class teak wood |
| 34 | Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer-in- charge. (Note:- Butt hinges and necessary screws shall be paid separately) 35 mm thick shutters |
| 35 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 36 | Demolishing damaged and cracked cement concrete manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or leaner mix (i/c equivalent design mix) |
| 37 | Provision for Lowering down of existing M.S. grill railing fixed on wall which is of low height, now below the road level for the safety and security of the monument, stacking the material carefully for refixing after raising of dwarf wall |
| 38 | Provision for providing and fixing existing MS Grill railing after the raising of wall height, fixed with cement concrete in 1:2:4 cement concrete & with the help of scaffolding pipe and narial rope making in proper alignment including all T&P article etc., complete. |
| 39 | Provision for fixing of M.S. angle iron of size 50x50x5 mm in \\"\\"Y\\"\\" shape. Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 40 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter open able length ( total length 90 m), having 50 nos rounds per 6 meter length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ meter (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 41 | Making soak pit 2.5 m diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 42 | Providing and fixing MS grill size 2.00m x 1.60m with 50 x 50 x 5mm size MS angle and16 mm square bar including cutting, hoisting, fixing in position and making bhala at top of each 16mm square bar with supply of all T&P etc required for proper completion of work. |
| 43 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand): Flush / Ruled/ Struck or weathered pointing. |
| 44 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand). Usage/Application Water Cooling Brand Aqua soft Type Cold Cooling Capacity120 LPH Warranty1 Year Body Material Stainless Steel Number Of Taps2 Weight150 kg Dispenser Single Dispenser Total Power1.5 kW Coin Operated Rs. 1,2,5,10 Dispensing300 ml,500 ml,1 ltr,2 ltr,5 ltr to 20 ltr Dimension 6.5 x 3.5 x 3.5 feet Please Enable Macros to View BoQ information |