| 1 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading and stacking of soils within a lead of 75m.as directed. The item includes trimming the sides of trenches, leveling, and dressing and ramming the bottom, bailing out water etc. as required, complete.Depth of excavation not exceeding 1500mm. For Pump house |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) For Pump house (a) with earth obtained from exavation foundation 1/5 . |
| 3 | Earth work in filling with carried earth arraged by the contractors with in a radius of 3km including cost of carried earth. |
| 4 | Single brick flat soling of Picked Jhama Bricks including ramming and dressing the bed to Proper level and filling joints with powderes earth or local sand. For Pump house |
| 5 | Cement Concrete with 30mm down graded Shingles excluding shuttering (1:3:6) in foundation : For Pump House. |
| 6 | Ordinary cement concrete ( mix 1:2:4) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes. B) River Bazree |
| 7 | Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes. B) River Bazree |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(b) Extra for works beyound the roof of ground floor/ initial 4.0m .(i) Upto 4th floor roof in each addl. Floor (1st floor)a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL |
| 9 | Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fixing and striking out after complection of works. ) upto plinth(a)25 mm. to 30 mm. thick wooden shuttering as per decission & direction of E-I-C. |
| 10 | 25mm. thick damp proof course with cement concretewith stone chips (1:1.5:3) [with graded stone aggregate10 mm nominal size] and admixture of water proofingcompound as per manufacturer's specification followedby two coat of polymer based paint, (1st coat after 4 to 5days of concrete laying and 2 nd coat just before brickmasonry work) as directed (cost of water proofingcompound & polymer based paint to be paidseparately).( Chequering not required over concrete orpainted surface). [Note: - Waterproofing as per item 9,polymer based paint as per item 8 (a) of subhead C ofSection (C). |
| 11 | Brick work with 1st class bricks in cement mortar(1:4)(a) In foundation and plinth |
| 12 | Brick work with 1st class bricks in cement mortar(1:6)(b) In superstructure, ground floor |
| 13 | 125 mm. thick brick work with 1st class bricks in cementmortar (1:4) in ground floor |
| 14 | (a) 75 mm. thick brick work with 1st class bricks set incement, sand mortar (1:4) in ground floor including H.B.netting in every alternate layers. |
| 15 | Labour for Chipping of concrete surface before taking upPlastering work. |
| 16 | Plaster (to wall, floor, ceiling etc.) with sand and cementmortar including rounding off or chamfering corners asdirected and raking out joints including throating, nosingand drip course, scaffolding/staging where necessary(Ground floor).[Excluding cost of chipping over concretesurface]ii) With 1:4 cement mortar(b) 20 mm thick plaster |
| 17 | b) 20 mm thick plaster(1:6) |
| 18 | (b) 15 mm thick plaster (1:4) |
| 19 | (c) 10 mm thick plaster (1:4) |
| 20 | Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100sq.m. |
| 21 | b) Applying 2 coats of Non-Toxic Acrylic Polymermodified Paint having adhesive & waterproofingproperties by mixing in proportion (1 liquid: 4cementitious material) or as per manufacturer'sspecification for water proofing layer in water tank etc.(No Departmental Cement is required) |
| 22 | Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels asdirected with topping made with ordinary or whitecement (as necessary) and marble dust in proportion(1:2) including smooth finishing and rounding off cornersincluding raking out joints or roughening of concretesurface and application of cement slurry before flooringworks using cement @ 1.75 kg/sq.m all completeincluding all materials and labour. 3 mm. thick topping(High polishing grinding on this item is not permitted withordinary cement).Using grey cement(ii) 25 mm. thick |
| 23 | Supplying and laying chequered tiles of any shade & ofapproved quality with (1:1½:3) cement concrete laid inpanels or patterns as directed in pavement, footpath etc.including necessary underlay 25 mm thick [avg] cementmortar (1:3) complete in all respect with all labour andmaterials. [Using cement slurry @ 4.4 kg/Sq.m at backside and @2.4 kg/Sq.m for joint filling] RedVariety(i) 25 mm. thick |
| 24 | Supplying, fitting & fixing 1st quality Ceramic tiles inwalls and floors to match with the existing work & 4 nos.of key stones (10mm) fixed with araldite at the back ofeach tile & finishing the joints with white cement mixedwith colouring oxide if required to match the colour oftiles inclu-ding roughening of concrete surface, ifnecessary or by synthetic adhesive & grout materialsetc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick &2 mm thick cement slurry at back side of tiles usingcement @ 2.91 Kg/Sq.m & joint filling using whitecement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto0.09 Sq.m |
| 25 | B) WALLWith Sand Cement Mortar (1:3) 15 mm thick & 2 mmthick cement slurry at back side of tiles using cement @2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including white |
| 26 | Colour washing with any shade with Stainers, asrequired including cleaning and smoothening surfacethoroughly :(ii) External surface (Ground floor)(b) Two Coats(i) Other than yellow, pink |
| 27 | Colour washing with any shade with Stainers, asrequired including cleaning and smoothening surfacethoroughly :(i) Internal surface (All floors)(b) Two Coats(i) Other than yellow, pink. |
| 28 | Supplying fitting and fixing in position approved P.V.C.door frame (Matt finish) made of extruded P.V.C.multichamber hollow section having dimensions 60mm x50mm x 2mm (+/- 0.2mm), horizontal section will bejoined with vertical section by galvanised steel screwsafter inserting two number steel brackets asreinforcement making suitable space for placing hinges,one steel tube 40mm x 20mm x 1.20 mm will be insertedon one full vertical side of the frame (hinge side) asreinforcement, the frame will then be fixed in theopening with the help of P.V.C. expandablefastner/wooden gutties and galvanised steel screwsincluding cost of all materials and labour, hire charges oftools and appliances, carriage of all materials, taxes andall other incidental charges complete |
| 29 | PVC Door Shutter-30 mm thick: Supplying fitting andfixing P.V.C. door shutter of approved quality & shade inposition, the style & rail of the P.V.C. door shutter will bemade of rigid P.V.C. multicavity hollow chamber of 59mm x30 mm section with 2.0 mm (+/-0.2 mm) wallthickness.Horizontal & vertical section shall be fixed toeach other by self tapping screws and 1 solid polymericor M.S. galvanised tubular 'L' shaped bracket 100mm x200mm in each corner of the shutter frame for placinghinges. Polymer based multicavity hollow section of 120mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness willbe fitted in the middle, reinforced by solid polymer bar of200 mm long at both ends and screws from both sidesas lock rail. The section frame will then be fitted in byPVC panels of size 100 mmx25 mm with wall thicknessof 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rodwill be inserted horizontally with both side check and nutsystem and stretches where fixing of hinges / hasp bolt /tower bolt / door ring are required to be strong enough towith stand wear and tear. The rate is inclusive of cost ofall materials, labour, and hire of tools and plants andappliancesi/c carriage of all materials taxes and all otherincidental charges |
| 30 | Precast pierced concrete jally work as per design andmanufacturer's specification including moulding etc. withstone chips and necessary reinforcement shutteringcomplete including fitting, fixing in position in all floors.(b) 37.5 mm thick panels |
| 31 | Galvanised Iron pipe outlet for water with bevelled endat outlet, supplied fitted and fixed complete includingpainting two coats to the exposed portion.(c) 40 mm. Dia |
| 32 | Welding in M.S. structural work with gas or electric:(b) Continuous weld. |
| 33 | Supplying, fitting & fixing UPVC pipes A- Type andfittings conforming to IS:13592-1992 with all necessaryclamps nails, including making holes in walls, floor etc.cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damagesincluding joining with jointing materails (Spun Yarn,Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia |
| 34 | c) Bend 87.5 degree(ii) 110 mm. Dia. |
| 35 | Supplying, fitting & Fixing EWC (Size- 710x370x810mm)in white glazed vitreous chinaware of approvedmake supplying, fitting and fixing in position completewith necessary nut and bolts. (Model Code No.S10221114-P Trap (CRUSE SET) of CERA orequivalent.) |
| 36 | Supplying, fitting and fixing Squating plate with integralflushing in white vitreous chinaware of approved make incement concrete (6:3:1) with jhama chips complete.(Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
| 37 | Supplying, fitting and fixing white vitreous china bestquality approved make wash basin with C.I. brackets on75 mm X 75 mm wooden blocks, C.P. waste fittings of32 mm dia., one approved quality brass C.P. pillar cockof 15 mm dia., C.P. chain with rubber plug of 30 mmdia., approved quality P.V.C. waste pipe with C.P. nut 32mm dia., 900 mm long approved quality P.V.C.connection pipe with heavy brass C.P. nut includingmending good all damages and painting the bracketswith two coats of approved paint. (i) 450 mm X300 mm size |
| 38 | Supplying, fitting and fixing 10 litre P.V.C. low-downcistern conforming to I.S. specification with P.V.C.fittings complete,C.I. brackets including two coats ofpainting to bracket etc. |
| 39 | Soft Close seat cover of approved make with lid andC.P. hinges, rubber buffer and brass screws suppling,fitting and fixing complete. E W C (Model Code No.B1520118 of CERA or equivalent.) |
| 40 | Supplying, fitting and fixing Stainless steel WallMounted Grab Bar. Load bearing capacity 150 kg,covered by Nylon surface with contour finish (for bettergrip) with Anti-bacterial surface complete. (Model CodeNo. B2210106 of CERA or equivalent.)600mm Long |
| 41 | Supplying, fitting and fixing bib cock or stop cock.Chromium plated Stop Cock (Equivalent to Code No.513(A) & 513(B) & Model - Tropical / Sumthing Specialof ESSCO or similar |
| 42 | Supplying, fitting and fixing push cock of heavy qualityand of approved make and brand. (b) Cast iron withbrass spindle (i) 15 mm |
| 43 | Supplying, fitting and fixing bib cock or stop cock.(f) (i) Polythene Bib Cock / Stop Cock (HD) with metalinlet (EMCO / ATLAS or equivalent) 15 mm |
| 44 | Supplying, fitting and fixing gunmetal wheel valve ofapproved brand and make tested to 21 kg per sq. cm.(for water lines only).20 mm |
| 45 | 25 mm |
| 46 | Supplying, fitting and fixing C.I. round grating.(i) 100 mm |
| 47 | Supplying, fitting and fixing PVC pipes of approvedmake of Schedule 80 (medium duty) conforming toASTMD - 1785 and threaded to match with GI Pipes asper IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo,nipple, longscrew, reducing socket, reducing tee, shortpiece etc. fitted with holder bats clamps, includingcutting pipes, making threads,fitting, fixing etc. completein all respect including cost of all necessary fittings asrequired,jointing materials and two coats of painting withapproved paint in any position above ground. (Paymentwill be made on the centre line measurements of totalpipe line including all specials. No separate payment willbe made for accesories, specials. Payment for paintingwill be made seperately)(a) For Exposed Work PVC Pipes25 mm dia. medium quality |
| 48 | 20 mm dia. medium quality |
| 49 | 15 mm dia. medium quality |
| 50 | Supplying P.V.C. water storage tank of approvedquality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity |
| 51 | Labour for hoisting plastic water storage tank(ii) Above 1500 litre upto 5000 litre capacity.(a) Upto 1st story from G.L |
| 52 | Labour for punching hole in plastic water storage tank u |
| 53 | Supply fitting & fixing of UPVC pipes (B Type) with allnecessary clamps nails including making holes in wall. &fittings conforming to IS-13592-1992A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 54 | ii) Plain Tee(b) 110 mm |
| 55 | x) Bend 87.5o(b) 110 mm |
| 56 | Construction of septic tank of different capacities as perapproved drawing with 1st class brick work in cementmortar (1:4) including two 560 mm dia. R.C.C. manholecover(heavy type)of approved make supplied, fitted andfixed in the 100mm thick R.C.C (1:1.5:3) top slab withnecessary fittings, 20mm ..................................... withclear water, removing foreign materials from thechamber and including constructing attached inspectionpit as per approved drawing and connecting allnecessary pipes, joints etc. with internal plaster workand artificial stone flooring is to be done with admixtureof water proofing compound @ 0.5% by weight ofcement with all costs of labour and materials. Note:- (i)Finished level of Septic Tank should be 400 mm. fromGround Level. (ii) Height of 50 mm. Ventilation pipe&Mosquito proof mesh, should be follwed as perIS:2470,Part- I.Payment will be made separetly on thebasis of actual height based on relevant I.S.Code. For 10 usersA) With Pakur variety. (SAIL/TATA/RINL) |
| 57 | Construction of circular soak well 2.5 metre deep in alltypes of sandy soils with dry brick work upto 1.6 metrefrom the bottom having 150 mm intermediate cementbrick work (1:4) band all round and cement brick work(1:4) upto 0.90 metre from top with 20 mm thick cementplastering (1:4) to inside face upto the depth of cementbrick work, 15 mm thick cement plaster (1:4) on outerface from top of the well upto G.I. and 6 mm thickcement plaster (1:4) on top of the R.C.C cover slabincluding filling bottom 1.00 metre of inside of the wellwith brick metal ( 50 mm to 63 mm size) including R.C.Ccover slab of 100 mm thick with cement conc (1:1.5:3)with stone chips with necessary reinforcement andshuttering including one 560 mm dia R.C.C manholecover(heavy type) of approved make supplied, fitted andfixed in the cover slab with necessary fittings, makingnecessary arrangements for pipe connections,excavation of well including shoring, dewatering andremoving the excess earth from the premises as perdirection complete in all respect with all costs of labourand materials. With 250 mm thick dry brick work and250 mm thick cement brick work (1:6) and 1.00 m insidedia.(SAIL/TATA/RINL) |
| 58 | Construction of Soak Pit with brick work in cementmortar (1:4) |
| 59 | Add for GST @18.00% |
| 60 | Add for L.CESS @1.00% Please Enable Macros to View BoQ information |