| 1 | Hiring charges for S & installation (Temporary) 415V, 62.5 KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 2 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 3 | Hiring charges for S & installation (Temporary) 440V, 125KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site including labour charges with necy. Inter connection of Generator. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 4 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 5 | Hiring charges for S & installation (Temporary) 440V, 35KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 6 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 7 | Hiring charges for S & installation (Temporary) 440V, 10KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 8 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 9 | Hiring charges for S& installation (Temporary) 440V, 5KVA, 50Hz 1ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 10 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 11 | S & charging of Diesel for smooth operation of D.G. set incl. carrying & storage (oil) from pump to site. |
| 12 | Temporary Neutral earthing arrangement for all 3-phase/ 1-ph DG (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 13 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 14 | Providing on hiring basis diff. sizes PVC/ Al/Ar Cable on/above ground/pole to pole fittings to fittings incl. dismantling after programme etc. |
| 15 | a) 3.5 core 120 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 16 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 17 | b) 3.5 core 95 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 18 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 19 | c) 3.5 core 50 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 20 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 21 | d) 3.5 core 35 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 22 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 23 | e) 4 core 16 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 24 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 25 | f) 2 core 10 sq.mm. PVC/Al/Ar (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 26 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 27 | Providing on hire basis incl. supply / drawing of single core copper wire for metal / sodium light, stall light, Fans,stage light, pelmet screen incl. dismentling as follows:- |
| 28 | a) 2 x 6 sq. mm. PVC copper wire(Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 29 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 30 | b) 2 x 4 sq. mm. PVC copper wire(Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 31 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 32 | c) 2 x 2.5 sq. mm. + 1x1.5 sq.mm . PVC copper wire (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 33 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 34 | Providing on hire basis incl. supply / drawing of single core copper wire for outdoor metal / sodium light, stall light, Fans & plug point incl. dismentling as follows:- |
| 35 | a) 2 x 6 sq. mm. PVC single core Al wire (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 36 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 37 | b) 2 x 4 sq. mm. PVC single core Al wire (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 38 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 39 | Supply & installation on hiring basis (Temporary) Industrial Main panel for DG sets & following switch etc. on suitable angle iron frame including inter connection wiring with socketing earthing attachment etc. & dismentling at the end of Programme etc.a) 250A, 415V,TPN SDFU switch with 3 nos 250A HRC for incommer -01 no(b) 500V, 600Amp capacity 4 bar copper busbar chamber made of 16 SWG CRCA sheet compring with 4 nos 300 Amp capacity eletrolytic tinned copper ber suppported on nonhygroscopic insulating chair.c) 250A 415V FP changeover switch - 01 nod) 100A, 415V,TPN SDFU switch with 3 nos 100A HRC for incommer -04 nose) 63A, 415V,TPN SDFU switch with 3 nos 63A HRC for incommer -04 nos |
| 40 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 41 | S & installation of MCB control panel for the diff. control i.e. fan light stage light etc. of folloing items. |
| 42 | a) S/F of 4 way TPN PBDB as incommer 100A FP Isolator & outgoing of 12 nos 32A SPMCB's (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 43 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 44 | b) S/F of (2+8) way SPNBDB's as incommer of 40A DP Isolator & outgoing of 08 nos 10A-16A SPMCB's (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 45 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 46 | S & installation of 250V 40 watt single tube light fittings incl. 1no 40watt tube lamp at stall & other places etc. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 47 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 48 | Supply of hire basis 48\\" celing fans (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 49 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 50 | Supply of hire basis 18\\" air circulator fans (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 51 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 52 | Supply installation of 12 watt LED (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 53 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 54 | Supply installation of 100 watt BC lamp (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 55 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 56 | Supply installation of 200 watt BC lamp (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 57 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 58 | Providing on hire basis 400 watt sodium vapour (SV)/ metal halide light fittings (Flood light) with control gear box incl. replacement of fuse lamp. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 59 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 60 | Providing on hire basis 400 watt sodium vapour (SV)/ metal halide light fittings with 9mtr pole with control gear box incl. replacement of fuse lamp.(Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 61 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 62 | Providing on hire basis 9 mtr Tower light fittings including flat iron ring suitable for SV/Matal lamp fittings with 6 nos 150 watt LED Flood light fittings with control gear box including necessary inter connection. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 63 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 64 | Providing on hire basis charges of 100 watt LED fittings at different places incl. necessary inter connection.(Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 65 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 66 | Providing on hire basis charges of 60 watt LED fittings at different places incl. necessary inter connection. (Rates for hiring & labour charges including materials & Carriage upto 4 days) |
| 67 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 68 | Providing on hire basis incl. Supply / instalation charges of 5/15 A plug with switch on casing board with earthing attachment at different places incl. necessary inter connection. (Rate for hire & labour charges including materials & carriage upto 4 days) |
| 69 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 70 | Temporary basis distribution wiring in 1.1KV grade 3x1.5 sq.mm single core stranded FR PVC insulated copper wire (App. Make) in 19mm bore ,3mm thick polythene pipe for horizontal & vertical run in wall & ceiling complete with all accessories to light points along with MCB/kit-kat fuse (For Strong Room) etc. as per site requirement (Rate for hire & labour charges including materials & carriage upto 4 days) |
| 71 | (Rates for hiring & labour charges including materials & Carriage per day beyond 4 days) |
| 72 | Supply & delivery of 2.0 Ton capacity Split type Room Airconditioner having the following Specification & features :- a) Cooling capacitiy normal (K. Cal/Hr): 6000 cooling cap (Min) Guaranteed (K. Cal/Hr) :5500. b) Star rating - 3 Star c) Rated Voltage - 230 V +/- 5% , Frequency- 50Hz d) Compressor Type - Rotary e) Minimum room discharge Air Flow Rate - 800 Cu.M/Hr. f) Cordless Remote Arrangement with all modernized provision of temperature setting,Fan speed option (Low/Medium/High), Auto Swing, Air direction setting, Air ventilation arrangement & other with connection for Temporary along with cable connection at different places (Rate for hire & labour charges including materials & carriage upto 4 days) |
| 73 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 74 | Supply & delivery of 2.0 Ton capacity window- type Room Airconditioner having the following Specification & features :- a) Cooling capacitiy normal (K. Cal/Hr): 6000 cooling cap (Min) Guaranteed (K. Cal/Hr) :5500. b) Star rating - 3 Star c) Rated Voltage - 230 V +/- 5% , Frequency- 50Hz d) Compressor Type - Rotary e) Minimum room discharge Air Flow Rate - 800 Cu.M/Hr. f) Cordless Remote Arrangement with all modernized provision of temperature setting,Fan speed option (Low/Medium/High), Auto Swing, Air direction setting, Air ventilation arrangement & other with connection for Temporary along with cable connection at different places (Rate for hire & labour charges including materials & carriage upto 4 days) |
| 75 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 76 | Hire charges of 415v ,5.5 TR capacity split type AC- machine having all its accessories with indoor unit (Tower/Duct type) and out door unit as required. Recommended size of copper tube are to be laid from condensing unit to cooling unit which should be insulated with the enclosed insulation pipe with poper amount of refrigerant are to be added for proper colling and maximmum efficiency of the machine. Gas lickage at each pipe connection & recommanded futty are tobe used to avoied air lickage, after that mending good damages to original finish. For keeping smooth flowing of condensed watter, drain hose are to be attached to the indoor unit without any lickage, the length of which should be outside the hall at a conveniente place for watter drainage. All electrical connection are to be done by switable rating og MCB controle & wiring in between cooling and condensing unit by switable size of PVC insulated flex copper cabble , including neccary inter connection , transportation charges, loading / unloading, maintanence, operation and guarding the installation of AC system with expart technician & helper etc. as per direction of EIC. |
| 77 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 78 | Hire charges of 415v ,4.0 TR capacity split type AC- machine having all its accessories with indoor unit (Tower/Duct type) and out door unit as required. Recommended size of copper tube are to be laid from condensing unit to cooling unit which should be insulated with the enclosed insulation pipe with poper amount of refrigerant are to be added for proper colling and maximmum efficiency of the machine. Gas lickage at each pipe connection & recommanded futty are tobe used to avoied air lickage, after that mending good damages to original finish. For keeping smooth flowing of condensed watter, drain hose are to be attached to the indoor unit without any lickage, the length of which should be outside the hall at a conveniente place for watter drainage. All electrical connection are to be done by switable rating og MCB controle & wiring in between cooling and condensing unit by switable size of PVC insulated flex copper cabble , including neccary inter connection , transportation charges, loading / unloading, maintanence, operation and guarding the installation of AC system with expart technician & helper etc. as per direction of EIC. |
| 79 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 80 | Supply. Delivery & Installation of 12 v 100 AH sealed maintanance free dry cell UPS System along with necessary wire / cord etc. connection as per direction of EIC. |
| 81 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 82 | Supply. Delivery & Installation of 1450 VA single phase 230 V, sine wave Inverter System of 12 V DC supply along with necessary wire / cord etc. connection as per direction of EIC. |
| 83 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 84 | Supply. Delivery & Installationof 185 ltr capasity refrigeratior along with voltage stabiliser with connection for Temporary along with cable connection at different places (Rate for hire & labour charges including materials & carriage upto 4 days) |
| 85 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 86 | Supply. Delivery & Installation of 6 KVA single phase 230 v 50Hz, 0.85 PF to unity sine wave UPS of 192 v DC charging supply with manual bypass arrangement including indication of mains on. invertar on, battaery low, over load, outpur under voltage, output over voltage, DC over voltage & audible alarm of intermittent beep for 30 seconds on mains fail. Battart low pre alarm at 80% of Battry discharge. intermitent beep for all other trip condition , digital metering and foult indication of micro controller based digital scrolling LD to display I/P voltage, O/P voltahe , Load current, Load % , charging current Battary voltage, 5 of battary charge. Fault indication mains off, invertar off, o/P under voltage, over voltge , battary low pre alarm and trip , riceived over vorvoltage, otuput over load, protechtion of O/P over load O/P shortcircuite, battly low trip, DC over voltage, etc. as per direction of EIC |
| 87 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) |
| 88 | Supply. Delivery & Installation of 12 V 150 AH INVA TUBULAR battary (IT 500 +) with necessary inter connection with inverter as per direction of EIC |
| 89 | (Rate for hire & labour charges including materials & carriage per day beyound 4 days) Please Enable Macros to View BoQ information |