| 1 | Supply and fixing of 3 mtr. G.I. decorative pole of approved make Base plate 12 mm thick having 3 mm thickness Complete with aluminium cast duly Polyurrethane painted, electric cable, bakelite sheet, MCB & foundation bolt with in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T & P complete in all respect. |
| 2 | Supply and fixing of 6 mtr. G.I. Octagonal pole of approved make (top dia 70 mm, Bottom dia 130 mm & Base plate 12 mm thick) having 3 mm, thickness with single arm bracket length of 1 mtr. length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T & P complete in all respect. |
| 3 | Supply and fixing of Circular LED 50 Watt Post top offering excellent uniform illumination and aesthetics in one go Made up of Pressure Die cast aluminium body and opal PC cover. IP 66 and IK 07 rating ensures it stands tall amid varied environmental conditions. |
| 4 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >120 <135 lm/Watt) output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 90 watt |
| 5 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 6 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 7 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 8 | Providing, laying and fixing 100 mm. dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. |
| 9 | Cost of road/floor restoration after road cutting including cost of labour T&P material etc. complete |
| 10 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 11 | 10 sq. mm 4 core |
| 12 | 6 sq. mm 4 core |
| 13 | 6 sq. mm 2 core |
| 14 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. |
| 15 | 10 sq. mm 4 core |
| 16 | 6 sq. mm 2 core |
| 17 | Supply and fixing of 63 Amp. TP with Nuetral link switch fuse unit Havells or Eq. |
| 18 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. panel will be outdoor type.Incomer : 32 A FP, 25kA MCCB with Thermal O/L & S/C Protection Release along with Incoming Phase Indicating Lights, & contactor, automatic street light control Timer Switch etc.– 1 No. with proper arrangements for connection of incoming cablesOutgoing : 16 A FP, 10 kA MCB, with O/L & S/C Protection & Rotary Handel- 03 Nos.with additional Bus bar sepearately at each outgoing with 4 way arrangements for proper connection of outgoing cables as directed by engineer in charge . |
| 19 | Supply and fixing of decorative 40 Watt to 45 Watt, LED Post top indirect light luminaire having Pressure die cast aluminium body and UV Stabilized PC Clear/ frosted glass cover, with driver set confirming to IP 66 and IK 08 protection, Potted driver (Not circuitory) complete in all respect.4800-5400 system lumens, >120 Lm/W, PF>0.95, THD<10% at full load, CRI >70, >300V Over Voltage Protection and auto restart feature, 4 KV internal Surge Protection, with 5 years warrantee |
| 20 | Making connection of each pole with cost of copper wire 1.5 Sq. mm 3 core, din drell, D.P. MCB, Backelite with labour |
| 21 | Total Cost Please Enable Macros to View BoQ information |