| 1 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11KV Line on 9 mtr long ST Poles with ACSR weasel Conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember of Sunari Hartayan. |
| 2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 3 | GI V Cross -arm with top Bracket including clamps |
| 4 | GI Channel X-arm including clamps and Angle for braces |
| 5 | 30 mm² ACSR weasel Conductor |
| 6 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 7 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 8 | Galvanized Nuts and Bolts |
| 9 | Danger Plates with Clamps |
| 10 | anti climbing device with clamps |
| 11 | Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 12 | Painting of 9 mtr ST poles with two coats of Aluminium paint. |
| 13 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 15 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11KV Line on 9 mtr long ST Poles with ACSR Rabbit Conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember of Bharat Nagar Feeder (Generation Colony). |
| 16 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 17 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
| 18 | GI V Cross -arm with top Bracket including clamps |
| 19 | GI Channel X-arm including clamps and Angle for braces |
| 20 | 50 mm² ACSR rabbit Conductor |
| 21 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 22 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 23 | Galvanized Nuts and Bolts |
| 24 | Danger Plates with Clamps |
| 25 | anti climbing device with clamps |
| 26 | Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 27 | Painting of 9 mtr ST poles with two coats of Aluminium paint. |
| 28 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 29 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 30 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11KV Line on 9 mtr long ST Poles with ACSR weasel Conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember at Babey Sundla. |
| 31 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 32 | GI V Cross -arm with top Bracket including clamps |
| 33 | GI Channel X-arm including clamps and Angle for braces |
| 34 | 30 mm² ACSR weasel Conductor |
| 35 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 36 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 37 | Galvanized Nuts and Bolts |
| 38 | Danger Plates with Clamps |
| 39 | anti climbing device with clamps |
| 40 | Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 41 | Painting of 9 mtr ST poles with two coats of Aluminium paint. |
| 42 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 43 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 44 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for the installation of 100 KVA sub station at Babey Sundla for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember |
| 45 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA Aluminium wound Distribution Transformer at latest Energy Efficiency level-2(New) IS 1180 part-1 2014 as per latest upto date amnedment with externally fitted MCCB with cable box and 4x4 mtrs suitable cable of rating with heavy duty accessories complete |
| 46 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
| 47 | 11 KV GO AB Switch 3 phase, 3 pole, 1200 Amp, vertical |
| 48 | 11 KV Horn gap fuse set 3 phase 1200 A |
| 49 | 120 mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
| 50 | 9 mtr. Long ST pole (ST-410 SP-33) |
| 51 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 52 | GI Channel /Angle/flat of sizes including clamps |
| 53 | Galvanized Nuts and Bolts. |
| 54 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 55 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 56 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 57 | PG Clamps |
| 58 | Danger Plates with Clamps |
| 59 | GI barbed wire for Anti climbing |
| 60 | 3 phase 4 wire Trivector meter with CT PT unit |
| 61 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 62 | Painting of 9 mtr ST poles with two coats of Aluminium paint. |
| 63 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11KV Line on 9 mtr long ST Poles with ACSR weasel Conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember at Bindla (Barmeen Feeder), Chakka Dandi (Gandhtop Feeder), Chakal-I (Sia Mehri) Marta Sunetar (Kulwanta Feeder), Pooji (Katwalt Feeder). |
| 64 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 65 | GI V Cross -arm with top Bracket including clamps |
| 66 | GI Channel X-arm including clamps and Angle for braces |
| 67 | 30 mm² ACSR weasel Conductor |
| 68 | 11 KV Polymeric Composite Pin insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 69 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 70 | Danger Plates with Clamps |
| 71 | Anti climbing device with clamps |
| 72 | Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 73 | Painting of 9 mtr ST poles with two coats of Aluminium paint. |
| 74 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 75 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 76 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Shifting of 100 KVA Sub Station at Dhalper (Shivnagar) and 63 KVA sub station at Dharnoo for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember. |
| 77 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 78 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 79 | Dismantling & Re-erection of 100 KVA Transformer alongwith allied Material like (LA, GO Switch, Horn Gap, Pin Insulator, Disc Insulator, GI Channel, Nuts & Bolts, Stay set etc.) |
| 80 | Dismantling & Re-erection of 63 KVA Transformer alongwith allied Material like (LA, GO Switch, Horn Gap, Pin Insulator, Disc Insulator, GI Channel, Nuts & Bolts, Stay set etc.) |
| 81 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 8 LT line on 8 mtr long poles, with 30 mm sq. ACSR Weasel conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember at Bindla (LOwer Barmeen Feeder), Marta Sunetar Girjli (Kulwanta Feeder). |
| 82 | 8 mtr. Long ST Pole (ST-410 SP-15) |
| 83 | GI M Clamps for shackle insulator |
| 84 | 30 mm² ACSR weasel Conductor |
| 85 | Shackle insulator |
| 86 | Galvanized nuts and bolts |
| 87 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 88 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11KV line on 9 mtr long poles, with 30 mm sq. ACSR Weasel conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember at Thard (Jakhani Back Feeder) |
| 89 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 90 | GI V Cross -arm with top Bracket including clamps |
| 91 | GI Channel X-arm including clamps and Angle for braces |
| 92 | 30 mm² ACSR weasel Conductor |
| 93 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 94 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 95 | Galvanized Nuts and Bolts |
| 96 | Danger Plates with Clamps |
| 97 | anti climbing device with clamps |
| 98 | Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip |
| 99 | Painting of 9mtr ST poles with two coat of Aluminium Paint |
| 100 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 101 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 102 | Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11KV line on 9 mtr long poles, with 30 mm sq. ACSR Weasel conductor for Permanent restoration of Damaged infrastructure due to flash floods during the month of August/Spetember at Sudhmahadev, Kossar, Bupp, Sarar, Gantwal, Chaksoo, (New Mantlai Feeder) |
| 103 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 104 | GI V Cross -arm with top Bracket including clamps |
| 105 | GI Channel X-arm including clamps and Angle for braces |
| 106 | 30 mm² ACSR weasel Conductor |
| 107 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 108 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 109 | Galvanized Nuts and Bolts |
| 110 | Danger Plates with Clamps |
| 111 | anti climbing device with clamps |
| 112 | Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip |
| 113 | Painting of 9mtr ST poles with two coat of Aluminium Paint |
| 114 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 115 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete Please Enable Macros to View BoQ information |