| 1 | As Per RUIDP SOR 2023 |
| 2 | supply and crection of galvanized iron pole with galvanizing done in single dipping (Average coating thickness minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-section designed to withstand the maximum wind speed as per Is 875. The pole shaft shall be made from sheet steel (HT steel conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding . There shall not be any circumferential Welding .The welding of poloe shall be done by Submerged Are welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226/ IS 2062) with provision for fixing 4 no. foundation bolts,This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside .The octagonal poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakclite sheet having 6A SP MCB and 16 sqmm stud type connector (4nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation. All as per pre approved by Engineer in -charge . For additional techinal parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.Poles with Octagonal cross section 9 Mtr |
| 3 | Providing and Laying RCC Foundation for Octagonal/ Conical street Light poles. High mast poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in -charge .For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. A) Excavation of pit for foundation size upto required depth from ground level B) Dressing of pit and Dry Stone Pitching 200 mm thick including supply of stones and Preparing surface complete . C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening ,cutting ,bending,placing in position and binding all complete. E) Centring and shuttering including strutting, prpping etc. and removal of form work for footing and Pedestal F) Providing & Fixing of 2no. Required size PLB HDPE Pipe & Foundation Bolts with template as per OEM Recommendations. G) Providing and Laying Reinforce cement concrete of M-25 grade in footing and Pedestal including curing the foundation for 7 days. H) Providing and Flaxing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10mm dia.Lungs on each face. Pole Foundation for Octagonal pole from 7 Mtr.To 9 Mtr. |
| 4 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S.Overhang (48.3 x 3.25 mm) with cap (400 x 88.9/ 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in -charge. For additional technical parmeters of products/ work , refer Annexure \\"A\\" attached with this BSR Single arm cverhang |
| 5 | Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS : 7098 P-1 of 1.1 KV with 114-Grade electorlytic aluminium conductor confirming to IS 8130 of Purity > 99.6 % round / flate strip armouring of cables .Inner/ outer sheath confirming to IS : 5831 in existing RCC/Hume / stoneware / PVC Pipe/ Open duct / cable trench / cable tray (with cable tie ) including testing etc . as require of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS : 10810. For additional technical parameters of product / work refer Annexure \\"A\\" attached with this BSR 16 sqmm 4 core |
| 6 | Add extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench .(c) Provide river sand bed of height 125 mm on top of the cable.(d) Lay the Protective common burnt clay F.P.S. Bricksm of class designation 75 / sand stone slabs of 50 mmthickness and 225 mm wide just above the sand bed vertically across the cable ( approx. 9 no. Bricks per Mtr.).(e) Backfill the excavated soil leaving 300mm from the Ground level.(f) Lay the cable warning tape and again back -fill the remaining portion of the trench upto the ground level and compacting the earth |
| 7 | P/L of Double wall corrugated HDPE Pipe confirming to IS: 16205 P-24, stiffness class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, tee at required Depth below the ground for laying cable of following Norminal Outer dia. MFR Test report from NABL accrediaed is to be submitted .( Excavation of Earth & Back filling with compaction is to be paid Extra ) All as per pre approved by engineer in - charges. For additional technical Parameters of products / work, refer Annexure \\"A\\" attached with this BSR .50 mm |
| 8 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor asn per PWD specification for electrical works with ISI marked (IS :694) and as per S 8130 : 2013 of 1.1 kV grade. Wire should be made from 99.90% Purity copper. Class 5 stranding in acc. to IS : 8130/IEC 60228 for lower watt loss, oxygen frce for less chances of oxidization , insulation PVC type A/C/D, flame retaredant as per IS 10810-53 , better amperage rating as per IS : 3961 part 5 in existing surface or recessed PVC/ MS conduit / casing capping making connections with copper Lugs of suitable size , Ferrules, lesting etc. as required . OEM Must have its own in house NABL nlab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \\"A\\" attached with this BSR 2 x 2.5 sq. mm |
| 9 | Providing & Fixing of IK08 ,IP 66 protected LED street Light Luminaire on existing bracket / pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation lins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) / Toughened glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each. The system efficacy >= 125 Im /wt and potted driver & has a unique BIS number with input Voltage Ac 120 to 270 v AC with High voltage Cutoff @>-300 v AC and Auto resetting ,safety , power Factor > 0.95 driver Efficiency >85% , THD(1)< 10% Humidity 10% to 90% RH working Temp -5C to 45C, driver current < 750mA. The luminaire shall be BIS certified and Trade mark certified .Life Expectancy equal or more than 50000 huring hrs with Minimum 70% lumen maintened ,CRI > 70 and CCT 5700k + 355K. surge protection shall be min > 4 kv internal and min 10 kv external inside drive compartment driver should be |
| 10 | Providing & fixing of 240/ 415 V AC MCB with positive isolation of 10 KA breaking capacity (B/c/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage , ISI marked IS 8828(1996)/ conforming to HEC 60898-1 2002, HEC 60947-2, low watt losses ,trip free mechanisum , energy limiting of class 3 as per HEC ,minimum phase termination capicity of 35sq .mm.,conductor line load reversibility ,IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20.000 upto 20 A rating and 10.000 upto 63 A , 5000 for 80 A & above rating including making connections , testing etc. as required . OEM shall have submit NABL/ CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in -charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Please Enable Macros to View BoQ information |