| 1 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 2 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core lwith necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 3 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 4 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 5 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 6 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 7 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 8 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 9 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 10 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 11 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. |
| 12 | Excavation in trenches , not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc and getting out in soft/loose soil complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed. |
| 14 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed |
| 15 | M&L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidation complete all as specified and as directed.Note:-Punned thickness shall be measured for payment purpose. |
| 16 | Supply and Laying old size bricks of size 230mm x 113 mm x 75 mm having designation 75 for cable protection complete all as specified and as directed. |
| 17 | S&F street light GI bracket made out of 40mm dia galvanised iron pipe 'Light grade' having 1.2 m length, bend to shape at 120 degree end welded as required including 02 Nos MS clamp of flat iron 40mm x 6mm including nuts bolts & washers of suitable size for fixing on wall complete complete all as specified and as directed |
| 18 | Supply, fixing & testing in replacement of LT panel Busbar cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900mmx600mmx500mm and supported with 4 Nos mild steel angle iron legs , duly painted with two coats of powder coated paint over one coat of red oxide primer, effectively PVC gasket and sealed, mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back both side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs, glands and comprising of supply and fixing of following accessories :- |
| 19 | (a) High conductivity Copper busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set.(b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e) MCCB 4 Pole 160 Amp 415 volt adjustable type thermal magnetic release with 25 KA breaking capacity & spreader both side as incoming control device : 01 Nos. (Schnieder/Havells/L&T/ABB/Legrand/Legrand) (f) Panel stand shall be made out of 40x40mmx5mm ISA angle of 60cm height and appropriate size as per panel. The same should be fixed in PCC 1:2:4 type B-I below ground level 30 cm and above ground 30 cm and above ground level 20cm in 'C' shape(g) Drawing of LT panel shall be got approved by GE before placingof order |
| 20 | Supply and errection of steel tubular swaged poles , 9 m long, type -410SP-31 confirming to IS 2713, applying two coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti-corrosive paint below ground level and making alternative black and white strip of 30cm each upto 1.5 m hight and including provision of MS base plate, final taper plug bolts, nuts, screws, drilling works including numbering to poles, erected & fixed in vertical position complete all as specified and as directed.Note : Excavation, PCC in foundation/plinth block/ coping cross arms, bracings, clamps etc shall be measured and paid separately |
| 21 | Supply, installation, testing and commissioning factory made thermoplastic/HDPE cable junction box IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205mm x 255mm x 112 mm depth with cable entry size of 10-25 sqmm with terminal including aluminium bus bar of 63amp-04 Nos and MCB SP, 6amp-01 No complete all as specified and as directed.Make:- Sintex or equivalent as approved. |
| 22 | Supply, fixing, connecting & testing in replacement of LED street light fitting 70 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. . |
| 23 | Supply, fixing, connecting & testing in replacement of LED street light fitting 35 Watt ,230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 24 | S&F in replacement of Integral single LED aviation light comprising of aluminium housing with polycarbonate enclosure including provn of three core cable of copper conductor of size 2.5 sqmm 3 core of white covering for making connection, fixing the fitting on wall including all necessary fixing accessories complete all as specified and as directed. |
| 25 | S&F in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampcomplete all as specified and as directed. |
| 26 | S&F in replacement of LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 27 | S&F in replacement of LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 28 | S&F in replacement of bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.5 m length bent at 120 degree to shape fixed on pole/wall with and including 50mmx6mmflat ironI clamps ,02 Nos with nuts, bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 29 | S&F in replacement of bracket for mounting flood light fitting made out of mild steel angle iron of size 40mmx40mmx6 mm of length not less than 1.0 m, fixed to pole/ earth and grouting in cement concrete 1:2:4 type B-2 with suitable size clamp, nuts & bolts including painting of bracket with two coat of synthetic enamel paint over a coat of red oxide primer including preperation of surfaces complete all as specified and as directed. |
| 30 | S&F in replacement of 25 mm external dia rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. |
| 31 | S&F in replacement of 2.5 Sqmm 3 core PVC insulated, PVC sheathed stranded copper Cable complete all as specified and as directed. |
| 32 | S&F of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based on Natural light Lux level. Required illuminance level for Switching ON is<= 30 lux and for switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCB's and Auto manual(Sensor By-pass) selection option should be enclosed in apole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade SMC Junction box conforming to IP54. For three phase load of 8KW(Swadeep-02EC8kW3P) with: 3Nos contactors, 3 nos incoming MCB's & 3nos outgoingMCB's of 25-32 Amps each and circuit wiring copper min 10 sqmm complete all as specified and as directed for the followings:-(a) Suitable of three phase load of 8 KW with contactors (single phase 3Nos), incoming & Outgoing MCB SP (6 Nos),rating of 25 Amp/phs & circuit wiring of min 10 sqmm. Make:- (i) Nature switch:Kakatiya Energy system/Bajaj/Healer, Contactors: BCH/L&T/ Schneider, MCB's: HAGER /Schneider /L&T (Exora/ AU series ) /C&S.(ii) Swadeep Cat No. swadeep -NAVDEEP-66-8kW3P or equivalent in siemens /Indoasian as approved |
| 33 | (b) Suitable of three phase load of 12 KW with contactors (single phase 3Nos), incoming & Outgoing MCB SP (6 Nos),rating of 40 Amp/phs & circuit wiring of min 10 sqmm. Make:-Swadeep Cat No. swadeep - NAVDEEP-66-8kW3P or equivalent in siemens /Indoasian as approvedNote applicable for item No 31(i)The rate quoted under this item is inclusive of nuts, bolts and clamp for fixing on pole/wall..(ii) The sensor must have warranty of minimum 2 year.(iii) Test certificate and warranty certificate must be provided by the contractor before claming the payment.(iv) The rate quoted is inclusive of marking description on the box . |
| 34 | S&F in replacement of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is <60 lux and for switching OFF >10 lux, along with part night operation facility of minimum 4 hours to Maximum 12 hours complete all as speciied and as directed |
| 35 | S&F in replacement to the existing panels and connection with using aluminum lugs/ferrule including disconnection and re-connection of cable and making necessary alteration in panel/door using welding work as required and cutting as required for proper fixing & connection complete all as specified and directed for the followings:-(a) MCB TPN, 32 Amps, 415 Volt, 'C' series, 10 KA |
| 36 | (b) MCB TPN, 63 Amps, 415 Volt, 'C' series, 10 KA |
| 37 | (c) MCB SPN, 06-32 Amps, 240 Volt, 'C' series, 10 KA |
| 38 | (d) MCB SPN, 63 Amps, 240 Volt, 'C' series, 10 KA |
| 39 | M&L for applying two coats of aluminium paint over a coat of red oxide on Steel tubular pole of length 09/11 m including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and making colour band with synthetic enamel paint of approved shade up to 1.2 m from coping level including numbering of poles in 150 mm dia of approved shade complete all as specified andas directed . |
| 40 | M&L for applying two coats of aluminium paint over a coat of red oxide on Steel tubular pole of length 4 m including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and making colour band with synthetic enamel paint of approved shadeup to 1.2 m from coping level including numbering of poles in 150 mm dia of approved colour paint complete all as specified and directed . |
| 41 | M&L for dismantling of of old damaged /cracked PCC coping and prepare the new coping for steel/PCC pole using PCC 1:3:6 type C-1 with 20 mm graded stone aggregater above ground level on existing foundation of pole size 450mmx450mmx300 mm high and plastering in cement mortar 1:4 , surface finished even and fair complete all as specified and as directed. |
| 42 | Checking, identifying the defect /faulty point of LT cable using Cable fault locator machine or by manual excavation and taking out bricks from the trench upto fault point along cable route and re-laying the same using old bricks/sand including returning filling and making good surface after rectification of defect complete all as directed for the following sizes of cable :-(a) Up to 50 sqmm 3.5/4 core |
| 43 | (b) 70 to 150 sqmm 3.5/4 core |
| 44 | (c) 185 to 240 Sqmm Note:- Cable fault locator machine with all T&P required for identifying the faulty point will be arranged by contractor and the cost of same is deemed to be included in unit rate . |
| 45 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detaction of fault location complete all as specified and as directed for the following size:-(a) 25 Sqmm to 50 Sqmm |
| 46 | (b) 70 Sqmm to 150 Sqmm |
| 47 | (c) 185 Sqmm to 240 Sqmm |
| 48 | Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified and as directed . |
| 49 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for pedestal of poles/ coping including necessary necesssary use and waste of formwork as required complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 50 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for pedestal of poles/ coping including necessary necesssary use and waste of formwork as required complete all as specified and as directed. Please Enable Macros to View BoQ information |