| 1 | Total amount of Sch 'A' Sec-I ( BUILDING WORKS ) Lump sum price worked out by the contractor for \\" BUILDING WORKS \\" as listed in schedule 'A' Part-I |
| 2 | Total amount of Sch 'A' Sec II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for \\" SITE CLEARANCE & Earth Works \\" as listed in schedule 'A' Part-II |
| 3 | Total amount of Sch 'A' Sec III (INTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY WORKS \\" as listed in schedule 'A' Part-III |
| 4 | Total amount of Sch 'A' Sec IV (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for \\" INTERNAL ELECTRIFICATION WORKS \\" as listed in schedule 'A' Part-IV |
| 5 | Total amount of Sch 'A' Sec V (SEWAGE DISPOSAL WORKS) Lump sum price worked out by the contractor for \\" SEWAGE DISPOSAL WORKS \\" as listed in schedule 'A' Part-V |
| 6 | Total amount of Sch 'A' Sec VI (AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for \\" AREA DRAINAGE WORKS \\" as listed in schedule 'A' Part-VI. |
| 7 | Total amount of Sch 'A' Sec VII (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS\\" as listed in schedule 'A' Part-VII. |
| 8 | Total amount of Sch 'A' Sec VIII (DEMOLITION OF EXISTING BUILDINGS WORKS) Lump sum price worked out by the contractor for \\"DEMOLITION OF EXISTING BUILDINGS WORKS\\" as listed in schedule 'A' Part-VIII. |
| 9 | Schedule 'A'Section-IX (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 6 siginifies this fact only. |
| 10 | INTERNAL ELECTRIFICATION WORKSM&L for Earthing complete with galvanised steel earth plate electrode 600 mmx600 mmx6mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters deep below normal ground level and filled with alternate layers of charcoal and salt with 15 cm thick layer , connected to galvanised wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron, 20 mm bore GI pipe (med grade) for watering, 15 mm bore GI pipe (light grade) for protection of earth lead, including necessary earth work in any type of soil, Earth pit of PCC (1:3:6) type C1 and precast earth pit cover made of RCC (1:11/2:3) type A1 duly reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab complete all as specified and as shown in Electrical Plate No 3 of SSR Part-I including testing on completion, complete all as specified and directed. |
| 11 | Supply & fix LED bulb 12 Watt, 230 volts AC 50 Hz Retrofit B22 base complete all as specified and directed. |
| 12 | Supply & fix wall mounted Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting with all accessories incl fastners,nuts,bolts,clamps etc, complete all as specified and directed.. |
| 13 | Concealed Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLSH, PVC insulated and sheathed cable 1100 volts grade, ISI 694 marked,multi stranded copper conductor including PVC concealed conduit medium grade ISI marked 20 mm dia with all its fittings,PVC junction boxes etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 18 modules with inner and outer modular cover plates and blank plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed, for the following: - Note:- (i) Cutting/chasing of wall etc. deemed to be included in quoted amount. (ii) Modular GI metal flush/sunken Box along with modular base/front cover plate are inclusive in the item . (iii) Only switches,sockets and fan regulators shall be measured and paid separately. |
| 14 | One light/exhaust/Call Bell point controlled by one, 1- way switch/bell push |
| 15 | One fan point controlled by one,one way switch through fan regulator |
| 16 | One socket outlet point 6 Amps on same board |
| 17 | One socket outlet point 6 Amps on independent board |
| 18 | One light point controlled by Two 2-way switches |
| 19 | Concealed Point wiring using approved colour coding as per IS, with stranded copper conductor 2.5 Sq. mm (nominal area), single core,Flame retardant low smoke and low halogen FRLSH, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 ,marked in multi stranded copper conductor including PVC cconduit medium grade ISI marked 20 mm dia with all its fittings,PVC junction boxes etc, modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any modules from 1 to 18 modules with inner and outer modular cover plates and blank plates, including FRLSH, rigid PVC insulated unsheathed stranded copper conductor 2.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified, and directed by Engineer-in-Charge. Note:- (i) Cutting/chasing of wall etc. deemed to be included in quoted amount. (ii) Modular GI metal flush/sunken Box along with modular base/front cover plate are inclusive in the item . (iii) Only switches and sockets shall be measured and paid separately. |
| 20 | Modular Fan step Regulator 2 module,120W suitable for BLDC fans complete all as specified and as directed. |
| 21 | Modular Bell push 6 Amps one module complete all as specified, and directed |
| 22 | Buzzer, Ding Dong Bell AC 230V single pole complete all as specified, and directed |
| 23 | Ceiling rose surface mounting type PVC/Polycarbonate, isolated body, 65x50mm, three terminals complete all as specified and directed. |
| 24 | S & F new generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed. |
| 25 | Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep, five star rated with brushless direct current motor(BLDC) complete in white colour with canopy and hanging rod with all accessories incl nuts,bolts,clamps etc, complete all as specified and directed. |
| 26 | Concealed Sub main Wiring with two run of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl medium grade PVC conduit of adequates size and fittings and accessories concealed in walls, floors ceilings and Cutting/chasing of wall complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.00 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly from main DB to Sub DB. Note :- Two run of 6 Sqmm + one run of 6 Sqmm as earthing lead including PVC conduit shall be considered as one unit each of one RM. |
| 27 | Concealed Sub main Wiring with four run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl medium grade PVC conduit of adequates size and fittings and accessories concealed in walls, floors ceilings and Cutting/chasing of wall complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.00 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly from main DB to Sub DB /AC's earth & plug Socket. Note :- Four run of 4 Sqmm + one run of 4 Sqmm as earthing lead including PVC conduit shall be considered as one unit each of one RM. |
| 28 | MCB, Single pole, 6 to 32 A, 230 V, 6 kA, 'B' curve, Complete all as specified and directed in the MCB DB Complete with connection testing and commissioning. |
| 29 | S&F MCB, SPN, 25 A, 230V, 6 kA, 'B' curve, Complete all as specified and directed. |
| 30 | S&F MCB, TPN, upto 63A, 415V, 10 kA, 'B' curve, in the DB complete withconnection testing and commissioning, complete all as specified and directed. |
| 31 | EXTERNAL ELECTRIC SUPPLY WORKS |
| 32 | Supplying & fixing of double walled corrugated HDPE duct pipe of 50 mm outer dia and inner dia 38mm confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and direcetd. |
| 33 | Material and labour for LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 4 core IS marked laid in trenches including testing and commissioning complete all as specified and directed. |
| 34 | SEWAGE DISPOSAL WORKS |
| 35 | Precast RCC (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in landing cover slab for manholes , septic tank set in cement mortar ( 1:6) including necessary form work complete all as specified and as directed. |
| 36 | Note: For the purpose of arriving at Contract sum, the amount of Schedule of credit (i.e Rs 222845.00) shall be deducted from the total amount arrived. Please Enable Macros to View BoQ information |