| 1 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 2 | M&L for Brickwork with old size sub class -B bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and as directed. |
| 3 | M&L for Brick work (except Brick) with old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) |
| 4 | Raking out joints/ pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc. |
| 5 | M&L for Cement mortar 1:4 Flush pointing to brick walls |
| 6 | M & L for Rendering 10mm thick CM 1:4 to brick or concrete surfaces trowelled to even and smooth finished surfaces without using extra cement. |
| 7 | Demolition of cement concrete(unreinforced)/ lime concrete of any description and in any position not otherwise specifically provided for including removing rubbish complete all as specified and directed. |
| 8 | M&L for Cement concrete in foundations,filling and mass concrete 1:4:8 type D- 2, 40mm graded aggregate. |
| 9 | M&L for cement concrete (1:2:4) type B-1 (20 mm graded aggregates) as in drain/surface channel, finishing the concrete surface even and smooth without using extra cement etc complete all as specified and directed. |
| 10 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends. |
| 11 | Providing, cement concrete (1:2:4),type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating, as directed kerbs or mud stops, rounded or chamfered on edges. |
| 12 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid,bedded and pointed in any mortar. |
| 13 | Demolition of cement concrete(unreinforced)/ lime concrete for as in ground floor n .exceeding 15cm thickness including removing rubbish complete all as specified and directed. |
| 14 | Provide 100mm thick Cement concrete type D- 2,1:4:8( 40mm graded aggregate) |
| 15 | Provide Screed bed or bedding layer of Cement plaster 1:6 of 15 mm thick for laying floor finishes |
| 16 | S&F of Chequered cement concrete tiles with grey cement and no pigment of 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors. |
| 17 | S&F of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment including 25mm thick sand cushining. |
| 18 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 19 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 20 | Removing excavated material(Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 21 | M&L for Hardcore of broken bricks of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface. |
| 22 | Demolition and breaking up of any bore dia. drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar. |
| 23 | M&L for Concrete bed to drain pipes of 300mm bore dia. including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:4:8 type D-2. |
| 24 | M&L for300mm dia , Reinforced concrete pipes, class NP 2 with one collar per length of pipe as per IS 458 : 2021 . |
| 25 | M&L for Concrete bed to drain pipes of 450mm bore dia. including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:4:8 type D-2. |
| 26 | M&L for 450mm dia , Reinforced concrete pipes, class NP 2 with one collar per length of pipe as per IS 458 : 2021 |
| 27 | Demolition of reinforced Concrete in cover slab of any description and in any position not otherwise specifically provided. |
| 28 | M&L for precast reinforced cement concrete type B1, 1:2:4 using 20mm graded stone aggregate in cover slabs (for manholes etc), water (tank/drain) cover, shelves, landing and similar articles with plain faces incl necessary moulds and setting in CM 1:4 complete (reinforcement to be measured separately) |
| 29 | M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Please Enable Macros to View BoQ information |