| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | All kinds of soils |
| 3 | Ordinary Rock |
| 4 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 5 | All kinds of soils |
| 6 | Ordinary Rock |
| 7 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 8 | Providing and laying of dry stone solling hand packed incluidng cost of loading unloading all sorts of carriage complete |
| 9 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone |
| 10 | Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. |
| 11 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 12 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 13 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 18 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 20 | Foundations, footings, bases of columns etc. for mass concrete. |
| 21 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 22 | Suspended floors, roofs, landings, balconies and access platforms, |
| 23 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 24 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 3 ( 1 cement : 3 fine sand) |
| 25 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 26 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 28 | Providing water proofing compound in RCC work |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): 1st Class Foreign Wood. |
| 30 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 35 mm thick 1st Class Foreign Wood |
| 31 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. foreign wood |
| 32 | P/F of 4 mm thick float glass panes including wooden bending |
| 33 | Providing and fixing fly proof wire gauge shutters to windows/ doors and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. |
| 34 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc.complete . |
| 35 | Doors 125 mm |
| 36 | Windoos 100 mm |
| 37 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 38 | 150x10 mm |
| 39 | 100x10 mm |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 41 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) |
| 42 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 43 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 44 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI: 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
| 45 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe , 25mm OD(SDR-7.4) |
| 46 | Providing and fixing 50 litre Capacity Geyser of approved brand Venus, Racold, Havels or like along with all neccasary accessories and fitting all complete as per directions of engineer in charge |
| 47 | 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS: 8931 |
| 48 | providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 49 | providing and fixing 15 mm nominal bore C.P. Wall mixer of approved quality conforming to IS : 8931 of approved brand like Jaguar, Cera etc as per directions of engineer in Charge |
| 50 | providing and fixing 15 mm nominal bore C.P. Single Lever Sink mixer of approved quality conforming to IS : 8931 of approved brand like Jaguar, Cera etc as per directions of engineer in Charge |
| 51 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 52 | Providing and fixing PVC Pipes Type B including Tees, Bends as required all complete as per directions of engineer in charge 100 mm dia |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 54 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 55 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 56 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.1 1 mm thick |
| 57 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 58 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510mm bowl depth 200mm |
| 59 | Supplying and fixing of 25 mm Ø medium class PVC conduit along with accessories insurface/recess including cutting of wall and making good the same in case of recessed conduit as required. |
| 60 | Providing and carrying out wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit) |
| 61 | Providing and carrying out wiring for heating points with 4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combined S&S 16Amp along with modular plate, suitable GI box and earthing the point with 2.0 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit) |
| 62 | Supplying and fixing double pole 63 Amp 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in MCB DB complete with connections, testing and commissioning etc. as required. |
| 63 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 64 | Supply of 200 mm nominal sweep Exhaust Fans including shutter from outside complete.Confirming to relevant Indian Standards |
| 65 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 66 | Providing, fitting and testing of LED flood light IP65 30W rating to pre-wired electric points |
| 67 | Providing and laying of armoured cable 95 mm, 3.5 core for main service line of reputed make in PVC pipes of required dia. to accommodate the service line including bends etc. from main transformer to the main panel board including copper thimbles, earth work excavation and filling for laying of cable complete. |
| 68 | P/L of bulk head electrical points in 1.5mm PVC copper wire fitted with 8 watt LED bulbs. |
| 69 | Providing and laying furnishing including EPE foam sheet |
| 70 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 71 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
| 72 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 73 | Providing and fixing mesh size 25x25mm including strengthening by wire or nuts, bolts and washers as required complete icluding carraige all complete as per the direction of Engineer-incharge. |
| 74 | Providing colour coated CGI sheets including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 75 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 76 | Connecting and Commisioning of intake chamber including provision for Sluice valves, Washout, welding, Bends, tees, making holes etc(to be paid as per actual execution at site) |
| 77 | Supply, Installation, Testing And Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer (Level-2) Capacity:-63 KVA Type of cooling: ONAN.Operating conditions:Input=11000 voltsOutput = 433 volts AC supply in 3-phase.Terminals:Input-3 No. HT Brass bush rods with insulators, washer, nuts etc. Output=4 No. LT Brass bush rods switch Insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. |
| 78 | Providing and fitting G.I Channel /Angle/ Flat/V Cross/F-Top of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of Gl channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirementSize of Channel= ISMC 75X40MM & ISMC 100x50mm |
| 79 | Supply, Installation, Testing And Commissioning of earthing station for electric substation, LT panel, DG set and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through Gl strip (25x3mm) as per relevant standards. Safe earthing electrode size: 80 mm dia, |
| 80 | Supply, Installation, Testing and commissioning of 02 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 32mm dia. Gl pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV).01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation) |
| 81 | Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation |
| 82 | Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type. |
| 83 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320 mm |
| 84 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 85 | Supply, installation, erection, Testing And Commissioning of 9 mtrs long H.T Steel Tubular pole of specifications ST-410 (SP-33). The job further includes drilling of holes for installation of various accessories wherever required the job further includes G.I wire earthing of pole as per REC standard. The tubular steel poles shall conform to the latest edition of Indian Standard specification IS: 2713 (Part-I, III): 1980 The materials used in construction of tubular steel poles shall be of the tested quality of steels of minimum tensile strength 540 MPa. The Poles shall be fitted with base plate as per above standard. The poles shall be applied with Red Oxide Primer and two coats of anti-corrosive Red paint at bottom up to the length of 4M and two coats of paint of silver shade for the rest |
| 86 | P/F of Galvanized nuts, bolts of various sizes as per site requirement |
| 87 | P/F Danger Plate with clamps on every HT pole |
| 88 | P/F GI barbed wire for anti climbing. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2050 m above the datum line. |
| 89 | Providing and Fitting of PG Clamps |
| 90 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 (Galvanized steel reinforced) for fitment of various accessories Size:-0.03 |
| 91 | Supply, Installation, Testing And Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at siteType: 3 Phase, 4 wire Measurements offered: KWh, KVARH, KVAh, KVAVoltage: 3x240V(415v),50HZ lb: 40A Imax: 200ABattery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetricalSuggested Make: Secure/L&TSealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION |
| 92 | Supply, Installation, Testing And Commissioning 11 KV cable termination connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line point and HT transformer |
| 93 | Supply, Installation, Testing And Commissioning of LT Distribution box for H.T transformer with MCCB For Incomer and SFU for outgoing circuits. The LT distributionBox is to be fitted on Gl Channels.Capacity of transformer: 63 KVA |
| 94 | Supply, Installation, Testing And Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at siteType: 3 Phase, 4 wire Measurements offered: KWh, KVARH, KVAh, KVAVoltage: 3x240V(415v),50HZ lb: 40A Imax: 200ABattery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetricalSuggested Make: Secure/L&TSealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION |
| 95 | Supply, Installation, Testing And Commissioning of 2 core, 3.5-Core, XLPE, 1.1KV and 11KV grade Armored Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. 70 sqmm, 3.5core, LT cable |
| 96 | Preparation of subgrade by excavating earth to an average of 22.5 cm depth, dressing to camber and consolidation with road roller of 8-12 tonne capacity including making good the undulation etc. and disposal of surplus earth upto 50 meters. |
| 97 | Supplying and stacking at site Graded crushed stone aggregate of size including carriage all complete |
| 98 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 99 | Providing and fixing PVC Pipes for weep holes all complete as per directions of Engineer incharge 75 mm dia including carriage |
| 100 | Carriage of material from source to dumping site at road by mechanical transport. |
| 101 | Cement steel Avg. 25 Km |
| 102 | Sand and 20 mm Agg. Avg. 30 Km |
| 103 | 40 mm Agg. Avg. Avg. 30 Km |
| 104 | Stones Avg. 20 Km |
| 105 | Bricks Avg. 28 Km |
| 106 | Extra Carriage of material from dumping site to actual site of work by Manual labour. Avg. 2300 mtr |
| 107 | Cement |
| 108 | Steel |
| 109 | Sand and 20 mm Agg. |
| 110 | 40 mm Agg. Avg. Please Enable Macros to View BoQ information |