| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soils |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 30% boulders. |
| 3 | Providing and laying in position boulders in concrete including cost of stones and carriage all complete |
| 4 | Providing and laying in position Reinforced cement concrete in Suspended floors, roofs, stair cases, lintels, chajjas, balconies etc. all work upto floor V level of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for:foundations ,footings bases of column |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies etc |
| 7 | Steel Reinforcement for RCC work including cutting, bending, binding and placing in position all complete (TMT bars of Fe500 Grade) |
| 8 | Brickworkwith common burnt clay bricks of class designation 75 in cement moratr 1:6 (1 cement: 6 coarse sand) in foundation and plinth |
| 9 | Extra for brick masonary above plinth level in superstructure upto floor V level |
| 10 | 15mm thick cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 11 | Providing and laying in position 40mm thick cement concrete flooring in 1:2:4 mix |
| 12 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6mm for diagonal braces. |
| 13 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 14 | Distempering with dry distemper of approved brand and manufacture( two or more coats) and of required shade on new work,over and including water thinnable priming coat to give an even shade. |
| 15 | Constructing soak pit 1.2x1.2x1.2m filled with brickbats including S.W drain pipe 100mm diameter and 1.20m long complete as per standard design |
| 16 | Add provision for hardware items,pipes ,water tank etc |
| 17 | Carriage of cement from source to site by mechanical transport or animal transport or by head load |
| 18 | Carriage of Sand from source to site by mechanical transport or animal transport or by head load |
| 19 | Carriage of Stone Aggregates below 20mm from source to site by mechanical transport or animal transport or by head load |
| 20 | Carriage of Stone Aggregates above 40mm from source to site by mechanical transport or animal transport or by head load |
| 21 | Carriage of Bricks from source to site by mechanical transport or animal transport or by head load |
| 22 | CIB( citizen information board) size 1'6''x2'6'' made of Granite stone ( complete job) Please Enable Macros to View BoQ information |