| 1 | Note :- Repair/ Maintenance/ updating including operation and regular maintenance of the Automatic water supply system shall be carried out through Original Equipment Manufacturer (OEM) i.e. M/S Recktronic Devices & Systems or through their authorized agent. The contractor shall submit documentary proof/evidence in this regard to the Engineer-in-Charge before execution of Work. In case of authorised agent, MoU documents of authorization shall be provided to the Engineer-in-Charge before execution of work. |
| 2 | Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 3 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as specified & as directed. |
| 4 | Surface excavation not exc 30 cm deep and averaging 15 cm deep & getting out in soft/loose soil complete all as directed. |
| 5 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 6 | All same as per serial item No 4 here-in-above but depth exc 1.5 m and not exc 3.0 m -do- |
| 7 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 8 | Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed. |
| 9 | M&L for cement concrete 1:3:6 type C1, using 20mm graded crushed stone aggregate as in stand posts, cills, steps, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 10 | M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed. |
| 11 | M&L for 100mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. Please Enable Macros to View BoQ information |
| 12 | M&L for 100mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. Please Enable Macros to View BoQ information |