| 1 | Dismantling and taking down un-servicable street light any type upto any height all as specified and as directed by Engineer-in-Charge. |
| 2 | S&F LED Street light 120 Watt WARM WHITE 3000K with silicon gasket for IP 66 (no glue) protection suitable upto 50mm outer dia holder fixed on existing poles. LED street light shall be made up of pressure die cast alluminium LM 6 alloy housing with toughend glass cover, high power LEDs and secondary lenses with IP 66 protections top opening for separate driver compartment with frame, brand, logo embossed, toughened glass cover. High power ceramic base, CRI > 70,and bolted inside the luminaire panel. Average life class of 50000 hrs metal body fully coated phase to phase protection at 440 V upto 4 hours and > 300 V auto cut and restart feature. Luminaries and driver shall be of same make, and making connections with twin core flexible copper cable complete all as specified and directed. |
| 3 | All as per Srl item No 2 here-in-before but capacity 90 watt all as directed by Engineer-in-Charge |
| 4 | All as per Srl item No 2 here-in-before but capacity 72 Watt all as directed by Engineer-in-Charge |
| 5 | All as per Srl item No 2 here-in-before but capacity 60 Watt all as directed by Engineer-in-Charge165 |
| 6 | All as per Srl item No 2 here-in-before but capacity 45 Watt all as directed by Engineer-in-Charge165 |
| 7 | S&F energy saving LED INVERTER TYPE STREET LIGHT 45 WATT AND BATTERY BACK UP OF MINIMUM 2 HOURS environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 security light with high power LEDs as light source, suitable for 40mm GI pipe, 5700K LED and making connection connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. |
| 8 | All as per Srl item No 07 here-in-before but capacity 60watt all as directed by Engineer-in-Charge. |
| 9 | S&F in replacement of unserviceable driver for LED street light of capacity 90 to 120watt for any make and type all as specified and directed by Engineer-in-charge. |
| 10 | All as per Srl item No 09 here-in-before but 30 to 72watt all as specified and directed by Engineer-in-charge. |
| 11 | S&F in repair of unserviceable driver for LED inverter type capacity 45 watt with lithium battery backup min 2 hours complete all as specified and directed. |
| 12 | All as per Srl item No 11 here-in-before but capacity 60 watt all as specified and directed. |
| 13 | S&F in repair metal core PCB/MCPCB copper and aluminium core boards of street light any make of capacity 60 watt 3000K complete all as specified and directed. |
| 14 | All as per Srl Item No 13 here-in-before but capacity 70-72 watt all as directed. |
| 15 | S&F in replacement of cable protection GI tubing light grade fixed along the pole/along the wall of size 50mm bore with necessary clamps complete all as specified and directed. |
| 16 | S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long, including MS clamps made of MS flat iron of size 40X4mm with nuts & bolts, washers complete drilling of holes for nuts and bolts etc all as specified and directed by Engineer-in-Charge. |
| 17 | S&F in repair of SINGLE phase 8 KW automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation based on natural light lux level. Switching off illuminance level of minimum 30 Lux and switching off illuminance greater than or equal to 10 Lux. The sensor having part night operation facility of min 4 hrs to maximum 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming outgoing MCBs be enclosed on a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade with hensel enclosures, conforming to IP 66 complete all as directed by Engineer-in-charge. |
| 18 | All as per Srl item No 17 above but for 5 KW automatic street light. |
| 19 | Repair/ tightening of end terminals of street light fitting, flood light, post top lantern of any size/capacity at any height and repair the street lights, flood lights and post top lantern having minor faults i.e loose connections, carbon deposition, shifting and refixing the same etc and making the light functional all as specified and directed by Engineer-in-Charge. Note:- (a) Complaint shall be done within 24 hrs after intimation by JE E&M/ Engineer-in-Charge failling which penalty of Rs 250/- per day per complaint will be levied on contractor.(b) One supervisor will report to JE E/M, Engineer -in-Charge on daily basis with complaint register. |
| 20 | S&F MCB 5 to 32 Amp, SP 'C' series complete all as specified and directed. |
| 21 | S&F in replacement of 3 pole power contactor of rating 25 to 45 Amps as per existing make and rating all as directed by Engineer-in-Charge. |
| 22 | S&F of LED post top lantern with die cast housing cum heat sink with PMMA diffuser in IP-66 fitting of 30watt all as directed by Engineer-in-Charge. |
| 23 | S&F bollard LED light capacity 16watt all as specified and directed. |
| 24 | Supply and laying weather proof flat twin core cable aluminium conductor 1100 volts grade size 10 Sqmm including taking out old cable complete all as specified and directed. |
| 25 | Supply and erecting steel tubular swaged poles confirming to IS: 2713 (Part I-III) : 1980 and should have hot dip galvanization ( 65 to 86 microns hickness) and should have minimum tensile strength 540 MPa complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) complete all as specified and directed. |
| 26 | S&F aluminium lugs eye type suitable for cable size 6 Sqmm to 10 Sqmm including necessary crimping with crimping tool complete all as specified and directed. |
| 27 | All as per Srl item No 26 here-in-before but of size 16 sqmm to 35 sqmm. |
| 28 | S&F LT straight through cable jointing kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 2/4 core of size 25 sqmm to 50 Sqmm complete all as specified and directed. |
| 29 | S&F LT straight through cable jointing kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 3.5/4 core of size sqmm 50 to 70 sqmm complete all as specified and directed. |
| 30 | S&F weather proof flat twin core cable aluminium conductor of size 2.5 sqmm 2 core all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in replacement of junction box size 200x140x95mm poly corbonate with glass fibre reinforced, environment friendly, recylable, UV resistant, halogen and silicon free anti acid and anti corrosive IP 66/67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and din rail for fixing the MCB including one No MCB SP 6A 10KA to control the street light with necessary clamps, nuts bolts to fix the junction box with poles complete all as specified and directed. |
| 32 | M&L for preparation of old painted surfaces of electric pole removing complete dust and other deposited materials by cleaning from steel tubular pole of length upto 9 to 12 metres cross arms, bracing, clamps etc and painting with one coat of aluminium paint, repainting existing marking on pole and replacement of reflective band of 3M brand RED -YELLOW -RED alternate coloured 3 numbers of minimum 5cm in height wrapped all around the pole complete all as specified and directed by Engineer in Charge. |
| 33 | S&F for piercing connector for service connection suitable for 35 sq mm AB cable all as specified and directed by Engineer-in-Charge. |
| 34 | Re-stretching of existing ACSR conductor of any size any type as required sag fixed on OH line incl un-winding the conductor and insulators/cross arms on poles properly binding with alumminum wire complete all as specified and directed. |
| 35 | M&L for aluminium conductor steel reinforced (ACSR) over size of ferret/ weasels/ mink/ beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified and directed. |
| 36 | S&F in repair of shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed. |
| 37 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and directed. |
| 38 | All as Srl item No 37 here-in-before but depth exc 1.5 mtr and not exc 3 mtr complete all as specified and directed. |
| 39 | Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified. |
| 40 | Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 41 | Supply and laying brick common burnt sub class \\"B\\" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable complete all as specified and directed. |
| 42 | M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed. |
| 43 | Providing PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/ stay assembly foundation etc complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for PCC 1:3:6 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/ stay assembly foundation etc complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping of pole including necessary form work and fair finished to exposed surfaces complete all as specified and directed. |
| 46 | M&L for road cutting, including excavation returning filling in, spreading levelling, well ramming in layers, soiling with, broken boulders stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing WBM of road, watering and ramming, 40 mm thick PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) for road patch repair work, section/ cross section area of cutting shall be same as of existing specification complete as specified and as directed by Engineer-in-Charge. |
| 47 | Supply and laying in replacement XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of cross sectional area 16 Sqmm 4 core laid in trenches/ ducts/ through pipes/under floor road/along the pole etc all as specified and directed by Engr-in-charge. |
| 48 | All as per Srl item No 47 here-in-before but of size 25 sqmm 4 core. |
| 49 | All as per Srl item No 47 here-in-beforfe but size 35 sqmm 3.5 core. |
| 50 | M&L for cross arms in replacement, bracing, supports, clamps and back plates, fabricated from structural steel section including nut bolts washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as specified and directed. Please Enable Macros to View BoQ information |
| 51 | M&L for cross arms in replacement, bracing, supports, clamps and back plates, fabricated from structural steel section including nut bolts washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as specified and directed. Please Enable Macros to View BoQ information |