| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed |
| 2 | Dismantling fencing wire mesh of any description complete all as specified and directed |
| 3 | Excavating in post holes (orsimilar holes) each n exc 0.5cu. m, getting out, returning,filling in and ramming earthor broken rubble mixed withearth around, in layers notexceeding 25 cm , watering and removing surplus soil to a distance n-exc 50 m and making good surface in soft /loose soil complete all as specified and directed. |
| 4 | M&L for Cement concrete type C2 1:3:6 ( using 40 mm graded stone agg) as in foundations,filling and mass concrete complete all as specified and directed. |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil/ black cotton soil complete all as specified and directed. |
| 6 | M&L for Cement concrete type D2 1:4:8 ( using 40 mm graded stone agg) as in foundations,filling and mass concrete complete all as specified and directed. |
| 7 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast con-crete articles complete all as specified and directed |
| 8 | M&L for brick work with fly ash bricks (using old size brick) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed |
| 9 | Taking down cement Plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of debris, complete all as specified and as directed |
| 10 | M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces with CM 1:6 on internal walls finished even and smooth (without using extra cement) complete all as specified and directed. |
| 11 | Material & labour for Rendering 15 mm thick on brick or concrete surfaces in CM 1:4 and finished fair and even complete all specified and directed. |
| 12 | M&L for preparation of surfaces plastered or unplastered new surface of wall by washing, rubbing down and stopping of surfaces and applying two coat of cement base paint on walls complete all as specified and directed |
| 13 | S&F of angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 14 | Supply of Chain link MS galvanisd fencing of size 50 mm x 50mm and 3.9 mm to 4 mm dia complete all as specified and directed. |
| 15 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and directed.(Note chain link fencing , nut bolts and line wires shall be measured seperately under supply only ) |
| 16 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long butnot exc 10 cm long of 5 to 10 mm dia complete all as specified and directed. |
| 17 | S&F Mild steel round bars 10mm dia as in tie rod cut to length, bent to shape required, for fixing of chain link fencing complete all as specified and directed. |
| 18 | S&F in repair for galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. (Each line wire to be measured). |
| 19 | Dismantling old structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 20 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or slidingwith and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed. |
| 21 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth,and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 22 | Preparation of new or previous untreated surfaces of steel and iron of any description n exc 10cm width or girth not when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 23 | M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping benching, bed plates and the similar including, weathering, slightly rounded or chamfered edges and throating complete all as specified and directed. |
| 24 | Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish off the premises complete all as specified and directed. |
| 25 | M&L for precast RCC 1:2:4 type B1 using 20mm stone aggregate as in landings, cover slabs, for manholes etc and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed. |
| 26 | S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed |
| 27 | Demolition of cement concrete (unreinforced)of any description and in any position not otherwise specifically provided . |
| 28 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of hard standing/paving /floor complete all as specified and directed |
| 29 | M&L100 mm th PCC 1:2:4 type B-2 (40mm graded stone agg) as in hard standing complete all as specified and directed. |
| 30 | M&L Black granite (of any type) work (table rubbed and polished) 20 mm thick as in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admixture of pigment to match with shade of granite including half round moulding and making hole for gas pipe over 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 31 | M&L for 75mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and rough to receive tile etc complete all as specified and directed |
| 32 | M&L for cement concrete type C2(1:2:4) (40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed . |
| 33 | M&L for Chequered tiles rubber pressed glossy finish (any colour) 40cm x 40cm x 35 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment including 15 mm screed bedding in cement mortar (1:4) complete all as specified and directed |
| 34 | M&L for 50 mm thick sand filling under floor or in foundation including watering and consolidation etc complete all as directed. |
| 35 | M&L for machine pressed precast concrete interlocking paver block, rubber finished any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade etc complete all as directed. |
| 36 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed |
| 37 | Excavation in trenches not exc 1.5m in depth and not exc 1.5m in width for fundation etc or for shafts, wells, cesspits, manholes, pier holes etc. not exc and getting out in hard/dense soil complete all as specified and directed. |
| 38 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed. |
| 39 | Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 40 | Cleaning of muddy/soil etc accumulated in existing drain and thrown away the spoil in low lying area exc 50m upto a distance of 250m completeall as specified and directed |
| 41 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed |
| 42 | M&Libro compacted for RCC M-30 grade pretressed designer precast compound wall 2100 mm GL compacted method post and panel size 2100x300x50 mm thick reinforcement with 4 Nos 3 mm dia HTSW wire & column of size 150 x 150 x 2850 mm reinforcement with 7 Nos 3 mm dia HTSW wire embaded in ground complete all as specified and directed |
| 43 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including prepration of surfaces complete all as specified and directed |
| 44 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 76,500.00] Please Enable Macros to View BoQ information |