| 1 | Demolition of brick work or stone/ boulder masonary built in cement mortar including all quoins arches, pillers etc but excluding ashler facings dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:6) with Sub class ‘B’ brick including manhole raising footpath etc complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of cement concrete (un reinforced) in ground floor and paving n/exe 15 cm thickness (below or above ground level) all as spd and directed |
| 4 | M&L PCC 1:3:6 type C-2 as in 75 mm thick sub base of floors all as specified and directed |
| 5 | M&L Prepainted Chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors using with grey cement and pigment, over 20mm thick screed bed in cm 1:6, all as specified. |
| 6 | Dismentling of stone slabs old granite as in plateform /pillers of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete all specified and directed. |
| 7 | Material and labour for 18-20mm thick granite stone slab as in window cill/pillers/ or platform,machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixtur of pigment to match the shade of granite stone including grinding/moulding and polishing laid over 15 mm thick sereed bed in CM 1:4 etc complete all as specified and directed |
| 8 | S&F MS framed work such as in grills,grating etc with ends of bars conforming to Fe--290 Gde-E-165 all as specified and directed. |
| 9 | M&L for preparing new steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat or red oxide primer complete all as specified and directed. |
| 10 | Taking down chowkats or frames with shutters ( without taking of shutters from the frame area exc 1.50 sqm but not exc 4 sqm.all as directed. |
| 11 | Providing and fixing 12mm thick plain toughned glass automatic Aluminium alloy sliding glass door IR sensor operated 4.2 meter wide in 4 parts or 1 meter each (02 x fixed panels and 02 x moving panels) for convinced and safety as per manufacturer's instructions all as specified and as directed by Engr-in-Charge. |
| 12 | M&L aluminium alloy powder coated (50 micron ) for partitions (fixed portion) with extruted built up standard tublar sections /appropriate sections of approved make confirming to IS 733 and IS 1285 fixing with dash fastners of required dia and size including filling up the gaps at junctions at top,bottom and sides with required EPDM rubber/neoprene gasket etc. including aluminium snap beading for glazing /paneling CP brass ,stainless steel screws including taking down old partition walls complete all as specified and directed . |
| 13 | S&F Toughned glass 10 mm thick fixed to windows frame work /partition including cutting to shape,drilling holes required complete all as specified and directed. |
| 14 | S&F 0.15 mm thick pvc film (strip type plain and transparent) on glasses pasted with required adhesive all as specefied and directed . |
| 15 | Taking down and Adjusting / repairing of Aluminium door/windows shutters, for easy closing/opening tightning of hinges or changing the position of hinges, tighetning of Glass/ Particle board by replacing rubber beading and clip packing, adjustments of floor machine for smooth opening and closing and refixing the same complete all as specified and directed. |
| 16 | M&L for providing and fixing stainless steel (grade 304) railing made of hollow tubes,channels,plates ,bulbs etc including welding,grinding,buffing,polishing and making curvature(wherever required)and fitting the same with necessary stainless steel nuts and bolts complete including fixing the railing with necessary steel dash fastners,of required size on the top of floor or the side of waist slabs with suitable arrangments all as specified and directed. |
| 17 | S&F collapsible steel doors of size Exc 4 Sqm each on rolleres,chennels,reveted portion for smooth openining/closing complete all as specified and directed. |
| 18 | M&L for chipping of spalled and loose concrete and cleaning rust from reinforement by sand blasting scrubbing down concrete surface with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adheisve on complete exposed surfaces of concrete to be gunited all as specified and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperature 75mm, avarage thickness of gunite n.exc 40mm thick in cement mortor (1:2) using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturer instructions and finally applying cement plaster over gunite surface of required thickness to give even uniform and smooth finish conforming to proper geometrics in cement mortor (1:3) to match the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias,parapets, lintels, columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 6 storey building including removing of small trees shrubs etc all as specified and as directed |
| 19 | M&L for decorative wall panelling with PVC louvered/Fluted/Plain 2D/3D wall panels with plastic and silicate mixture as the core material within and surface with PVC foil on the top with thickness of panel 10mm to 20mm, width of 150mm to 200mm and length of 2.74/3.05 (9' or 10') meters of POLYWOOD or equivalent brand Wt of PVC pannel is 4.5 kg/sqm and PVC percentage in wall panels is more than 40% including necessary L/H/U corner profile and fillets. WPC Wall panel are termite proof , water proof and usable on the damp walls, fixed to wall/ ceiling surface as per manufacturer instruction complete all as specified and directed by Engr-in-charge. |
| 20 | M&L aluminium alloy powder coated (50 micron ) for door window, ventilators etc with extruted built up standard tublar sections /appropriate sections of approved make confirming to IS 733 and IS 1285 fixing with dash fastners of required dia and size including filling up the gaps at junctions at top,bottom and sides with required EPDM rubber/neoprene gasket etc. including aluminium snap beading for glazing /paneling CP brass ,stainless steel screws including taking down old partition walls complete all as specified and directed . |
| 21 | S&F aluminium powder coated section door shutters consisting top rail and style 82.77X44.45X1.60 mm thick bottom and lock rail 150X44.45X1.60 mm including jointing clips,aluminium snap beading,rubber gasket,glazing clips,two aluminium handles of size 200mm,01 No. tower bolt 200 mm ,necessary hinges per leaf complete all as specefied and directed.Note:-Glass and boards shall be measered and paid saprately. |
| 22 | S&F 4.80mm thick tinted glass fixed to aluminium door /window /partitions etc of any size complete all as specified and directed. |
| 23 | Taking down cement plaster/grit plaster/rough cast plaster on brick or stone walls incl raking out joints hacking for key scrubbing down with water etc complete all as specified. |
| 24 | M&L 15mm thick rendering in cement mortar 1:6 on fair faces of new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and directed. |
| 25 | M&L 5mm thick rendering in cement mortar 1:3 on ceiling new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and directed. Please Enable Macros to View BoQ information |
| 26 | M&L 5mm thick rendering in cement mortar 1:3 on ceiling new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and directed. Please Enable Macros to View BoQ information |