| 1 | Supply and laying in replacement XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of cross sectional area 300 Sqmm 3.5 core laid in trenches/ ducts/through pipes/in floor road/along the pole etc all as specified and directed by Engr-in-charge. (Note : Excavation earth work, brick protection and sand cushioning shall be measured and paid for separately). |
| 2 | All as per srl item No. 01 here-in-before but size 240 Sqmm 3.5 core. |
| 3 | All as per srl item No. 01 here-in-before but size 185 Sqmm 3.5 core |
| 4 | All as per srl item No. 01 here-in-before but Size 150 Sqmm 3.5 core |
| 5 | All as per srl item No. 01 here-in-before but size 120 Sqmm 3.5 core |
| 6 | All as per srl item No. 01 here-in-before but size 95 Sqmm 3.5 core. |
| 7 | All as per srl item No. 01 here-in-before but size 70 Sqmm 3.5 core. |
| 8 | All as per srl item No. 01 here-in-before but size 50 Sqmm 3.5 core. |
| 9 | All as per srl item No. 01 here-in-before but size 35 Sqmm 3.5 core. |
| 10 | All as per srl item No. 01 here-in-before but size 25 Sqmm 4 core. |
| 11 | All as per srl item No. 01 here-in-before but size 16 Sqmm 4 core. |
| 12 | S&F in repair MCCB, AC 415 Volts, 100 Amp rating, breaking capacity of 16 KA, adjustable thermal and fixed magnetic with two side spreader thermal kit, 3 pole conforming to IEC :60947-II/ IS:13947-II all as specified and as directed by Engineer-in-Charge. |
| 13 | S&F in repair MCCB 4 Pole , 415V, adjustable type, 250 Amps with breaking capacity 36 KA all as specified and as directed by Engineer-in-Charge. |
| 14 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and directed. |
| 15 | All as per item No 14 here-in-before but depth excd 1.5 mtr and n. exc 3 mtr all as specified and direted. |
| 16 | Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 17 | Returning, filling in, including spreading, leveling,watering and well ramming in layers n.exc 25 cm thick in soft loose soil all as specified. |
| 18 | Supply and laying brick common burnt sub class \\"B\\" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable all as specified. |
| 19 | M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed. |
| 20 | S&F in repair for cable protection GI tubing light grade fixed along the pole/wall/under road of size 100 mm bore with necessary clamps, nut and bolts all as specified and directed by Engineer -in-Charge. (Note : Clamps,nut and bolt will be measured and paid separately). |
| 21 | All as per Srl item No 20 here-in-before but size 80mm. |
| 22 | All as per Srl item No 20 here-in-before but size 50mm. |
| 23 | All as per Srl item No 20 here-in-before but size 40mm. |
| 24 | M&L for cross arms in repair , bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers, welding, bending , cold or hot drilling holes for bolts of any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified. |
| 25 | M&L for aluminium conductor steel reinforced (ACSR) over size of ferret, weasels, mink, beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified. |
| 26 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/stay assembly foundation etc all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for PCC 1:3:6 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/stay assembly etc all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in coping of poles including necessary form work and fair finish to exposed surfaces complete all as specified and directed. |
| 29 | M&L for stay assembly comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including flat iron clamps 50x6mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long stay bow 400x14 mm, GI steel plate 300x300x6mm, loop insulator of size 90x140mm clearance hole 16 mm including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate no 1 of SSR part-I 2009 on page No 495 complete all as specified and directed. ( Note : Excavation & PCC works shall be measured and paid separately). |
| 30 | Supply and erecting steel tubular swaged poles confirming to IS: 2713 (Part I-III) : 1980 and should have hot dip galvanization ( 65 to 86 microns thickness) and should have minimum tensile strength 540 MPa complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) complete all as specified and directed. |
| 31 | Supply and erecting vertically prestressed concrete LT pole 9.0 mtr long 102 x 172mm at top and 102mm x 279mm at bottom class 10 all as specified and directed. |
| 32 | S&F shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for synthetic chequered insulated mat, ISI marked of size 2mx1mx19mm Conforming to IS- 15652 / 2006 complete all as directed by Engineer-in-Charge. |
| 34 | M&L for earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 35 | M&L galvanised steel wire of 4 SWG dia as earth wire for overhead line fixing of the same on the pole including dismantling existing complete all as specified and directed. |
| 36 | M&L for re-stringing/ stretching of existing ACSR conductor of any size any type as required sag fixed on OH line incl unwinding the conductor and insulators/cross arms on poles properly binding with alumminum wire all as specified and directed. |
| 37 | M&L for boring hole under the road/ hard standing using trenchless machine/ equipments complete all as specified and directed. |
| 38 | S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3½ core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm, Indoor/ outdoor type complete all as specified and directed. |
| 39 | All as per Srl item No 38 here-in-before but of size 150 to 185 sqmm. |
| 40 | All as per Srl item No 38 here-in-before but of size 70 to 120 sqmm. |
| 41 | S&F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm complete all as specified and directed. |
| 42 | All as per Srl item No 41 here-in-before but of size 150 to 185 sqmm. |
| 43 | S&F aluminium lugs, eye type, suitable for cable size 16 to 25 sqmm including necessary crimping tool complete all as specified and directed . |
| 44 | All as per Srl item No 43 here-in-before but of size 35 sqmm. |
| 45 | All as per Srl item No 43 here-in-before but of size 50 sqmm. |
| 46 | All as per Srl item No 43 here-in-before but of size 70 sqmm. |
| 47 | All as per Srl item No 43 here-in-before but of size 95 sqmm to 120 sqmm. |
| 48 | All as per Srl item No 43 here-in-before but of size 150 sqmm to 185 Sqmm. |
| 49 | All as per Srl item No 43 here-in-before but of size 240 Sqmm. |
| 50 | All as per Srl item No 43 here-in-before but of size 300 Sqmm. |
| 51 | Cutting/trimming of tree branches of any width/ girth up to 3 mtr distance of LT over load lines including collection and depositing the retrived timber at a place as directed by Engr-in-Charge. (Note :- (i) Each span is having a distance 35 mtr approximately. (ii) All cutting branches of tree shall be thrown away at approximately 500-700 mtr away as directed). |
| 52 | S&F piercing connector for service connection suitable for 95 to 120 sq mm AB cable all as specified and directed by Engineer-in-charge. |
| 53 | M&L for painting to LT steel tublar pole with one coat of aluminium paint complete above ground level including all MS fitting street light brackets of MS flat angle iron GI pipe etc and numbering of poles as marked by existing number with correct size including removing and cleaning of old painted surface all as specified and directed |
| 54 | M&L for painting the PCC pole of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) including all MS fitting street light brackets MS flat angle iron GI pipe etc complete all as specified and directed to match the existing poles. |
| 55 | M&L for fault detection in damage UG Cable by using cable fault ditector/locator to accuracy of 2 meter for various location in the area under GE Tibri for UG Cable of any size and any type upto 1.1 KV grade including excavation and earth work in any type of Strata 8x2x.60 m to visually inspect/repair the damage cable when and where detected by Engineer -in-charge. (Note : (i) Straight through joint shall be measured and paid separately.(ii) The complaint shall be done within 24 hrs after intimation by JE E/M/ Engineer -in- charge on phone call, whats app msg or through letter failing which penalty of Rs 500/- per day per complaint will be levied on contractor. |
| 56 | S&F in repair heavy duty PVC spacer for LT 1100 Volt grade suitable for 5 ACSR conductor of size required at site complete all as specified and directed. |
| 57 | S&F in repair heavy duty PVC spacer for LT 1100 Volt grade suitable for 3 ACSR conductor of size required at site complete all as specified and directed. |
| 58 | M&L for purning the branches of broken tree any grith on the ACSR conductor LT/HT due to strom or any situation and shall be thrown approximately 500 Mtr away after that jointing and restreching the broken ACSR conductor all as specified and directed by Engineer -in- Charge.Note : (i) Contractor to provide ladder, transport, tools and eqpt for purning the branches.(ii) The complaint shall be done within 12 hrs after intimation by JE E/M / Engineer -in- charge on phone call, whats app msg or through letter failing which penalty of Rs 500/- per day per complaint will be levied on contractor. (iii) Restreching of conductor will be measured and paid separately. |
| 59 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Rs. 2,50,064.00 Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |