| 1 | Dismantling of Flexible Pavements Dismantling of flexible pavements and disposal of ismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per MoRTH Specification Clause 202By Mechanical MeansBituminous Courses |
| 2 | Dismantling of Cement Concrete Pavements as per MoRD Specification Clause 202. Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately |
| 3 | Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches wi dressing of sides and bottom and backfilling in trenches withexcavated suitable material. Ordinary soil Upto 3 m depth |
| 4 | Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches wi dressing of sides and bottom and backfilling in trenches withexcavated suitable material. Ordinary soil 3 m to 6 m depth |
| 5 | Carriage of material from quarry / crusher to work site including loading, unloading and stacking all complete.Earth, Sand, Lime, Morrum manure or sludgeAdd for each 50 M (upto 500 M.) |
| 6 | Carriage of material from quarry / crusher to work site including loading, unloading and stacking all complete.Earth, Sand, Lime, Morrum manure or sludgeAdd for each 1 Km beyond Ist Km (upto 5 Km.) |
| 7 | Carriage of material from quarry / crusher to work site including loading, unloading and stacking all complete.Earth, Sand, Lime, Morrum manure or sludgeAdd for each 1 Km beyond 5 Km (upto 10 Km.) |
| 8 | Barricading with sal ballies as per design including tying with vertical posts by coconut strings complete in all respect with two horizontal members and vertical supports upto 2.5m centre to centre and for 3 days period including removal and cleaning the site complete in all respecHeight 1.2m upto 1.5m above ground levelComplete |
| 9 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete in all respect as per specificationsSize 2.00 M x 2.00 M |
| 10 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete in all respect as per specificationsSize 1.50 M x 1.50 M |
| 11 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete in all respect as per specificationsSize 1.25 M x 1.25 M |
| 12 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete in all respect as per specificationsSize 1.00 M x 1.00 M |
| 13 | Precast Box Culvert - Providing and Fixing in position precast cement concrete Box - Culvert as per design and shape using coarse aggregate and fine aggregate derived from natural resources, ordinary portland / admixture as per design mix IS 456-2000 and standard like Indian standard international standard viz Japanese Industrial Standard (JIS) / Providing and Fixing in position precast reinforced cement concrete Box -Culvert or Cable Crossing Boxes as per design and shape, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortIand flag cement, admixture* in recommended proportions as per IS: 456-2000 and standard like Indian standard international standards viz. Japanese Induslrial Standards (JIS)/ US standard/EU standard having of strength not less than M-50. using Thermo-Mechanically created bars (TMT/TMX) FE SOOD or more conforming to IS 1786 reinforcement bar and capable of carrying a wheel load of 32.5 zones with earth cushion 0.20 m to 3.00 m for heavy vehicle movement. Precast reinforced cement concrete drains using, service Crossing / stormwater etc. Rale includes aII cost of material, labor charges at the plant, cost of reinforcement formwork and lifting accessories, and transportation up Io work at fhe site. Rate excludes unloading lhe material at site, bids, and lift. All work up to plinth level: making necessary holes of required sizes for carrying lhroug h service lines etc., providing steel hooks for lifting, etc. .the work exciting as per the direction of Engineer in-charge. Nole: Rate shall also include technical assistance for the installation of producls at one time. 2500 X 2000 |
| 14 | Precast Box Culvert - Providing and Fixing in position precast cement concrete Box - Culvert as per design and shape using coarse aggregate and fine aggregate derived from natural resources, ordinary portland / admixture as per design mix IS 456-2000 and standard like Indian standard international standard viz Japanese Industrial Standard (JIS) / Providing and Fixing in position precast reinforced cement concrete Box -Culvert or Cable Crossing Boxes as per design and shape, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /PortIand flag cement, admixture* in recommended proportions as per IS: 456-2000 and standard like Indian standard international standards viz. Japanese Induslrial Standards (JIS)/ US standard/EU standard having of strength not less than M-50. using Thermo-Mechanically created bars (TMT/TMX) FE SOOD or more conforming to IS 1786 reinforcement bar and capable of carrying a wheel load of 32.5 zones with earth cushion 0.20 m to 3.00 m for heavy vehicle movement. Precast reinforced cement concrete drains using, service Crossing / stormwater etc. Rale includes aII cost of material, labor charges at the plant, cost of reinforcement formwork and lifting accessories, and transportation up Io work at fhe site. Rate excludes unloading lhe material at site, bids, and lift. All work up to plinth level: making necessary holes of required sizes for carrying lhroug h service lines etc., providing steel hooks for lifting, etc. .the work exciting as per the direction of Engineer in-charge. Nole: Rate shall also include technical assistance for the installation of producls at one time. 2500 X 2500 |
| 15 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mm nominal size). |
| 16 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. |
| 17 | Add extra for providing richer mixes respectively at all floor levelsProviding M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 18 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 19 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 20 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and MoRTH specifications Clauses 1009,1600 and 2302 |
| 21 | Construction of solid block masonry of M20 grade solid concrete block having nominal size 400 mm x 200 mm x 200 mm in cement mortar 1:3 upto plinth level with all lead & lift. |
| 22 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick . |
| 23 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 24 | Providing and fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc.for drain Opeining Size 451 to 700 mm Standard Drain Cover Size 1000mm x 800mm x 100mm |
| 25 | Providing and fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc.for drain Opeining Size 701 to 1200 mm Standard Drain Cover Size 1500mm x 600mm x 125mm |
| 26 | Providing and fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc.for drain Opeining Size 1201 to 1500 mm Standard Drain Cover Size 2100mm x 500mm x 150mm |
| 27 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905.600 mm dia |
| 28 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905.300 mm dia |
| 29 | Providing of 5 HP diesel dewatering pump with hose pipe in required length on hire charges with P.O.L. the Pump should be complete with suction & delivery attachment as per site requirements.Only pump with operator & helper |
| 30 | Providing of 5 HP diesel dewatering pump with hose pipe in required length on hire charges with P.O.L. the Pump should be complete with suction & delivery attachment as per site requirements. |
| 31 | Providing of Mud pump with hose pipe in required length on hire charges with P.O.L., the pump should be completed with suction and delivery attachment as per site requirement. 20 HP Mud pump tractor mounted with driver, operator and helper |
| 32 | Providing, fixing, maintaining, shifting & refixing, barricading of a steel portable barricade with horizontal sheet 0.60 mtr wide, 2.4 mtr in length fitted on a “A” frame and sheet painted with 2 coats of yellow paint, lettering (CAUTION, JDA AT WORK, DRIVE SLOW) on sheet with RED paint & border with reflective paint at the time of every shifting, traffic diversion arrangement, safety guard, suitable lightning arrangement during night if required, complete in all respect till completion of the project as per technical specification and direction of Engineer-In-charge and same shall be possessed by the contractor after completion of the project. Payment under this item will be released:- (1) 50% at the time of providing new barricading at the time of start of project at location and plan as approved by the Engineer & certification (2) 50% After completion of project including shifting, re-erecting and maintaining the barricading in position, during entire construction tenure with requisite manpower/flagman etc. Complete for guiding traffic and safety etc and dismantling after completion of project. |
| 33 | Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401. For Grading I Material |
| 34 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and MoRD Specification Clause 406. By Mechanical Means with 1 km leadBy Mechanical Means with all lead |
| 35 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base(WBM/WMM) including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRTH Specification Clause 502 |
| 36 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per MoRTH Specification Clause 503. |
| 37 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per MoRTH Specification Clause 503. |
| 38 | Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tones per hour using crushed aggregates of specified grading, premixed with bituminous binder minimum @ 4.0 & 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specifications Clause 505 complete in all respects. Bitumen (VG-30) Grading - II (26.50 mm (Nominal Size)) |
| 39 | Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder minimum @ 5.2 & 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specifications Clause 507 complete in all respects. for Grading-II(13 mm nominal size) Bitumen (VG-30) |
| 40 | Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160\\" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements. |
| 41 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104P.C.C grade M 10Nominal mix 1:3:6 |
| 42 | Construction of un-reinforced , plain cement concrete pavement M-35 (Grade), thickness as per design, over a prepared sub base, with 43/53 grade cement as per Clause 602, coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a in fully automatic Batching Plant and transported to site in transit mixer for having continuous agitated mixer, manufactured as per approved mix design including pumping of R.M.C. from transit mixer to site of laying , with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge laid with a Fixed Form Paver (laying and fixing of 150 micron thick polythene Film and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using water finishing to lines and grade as per drawing and MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments (Dowel Bars will be paid seprately). |
| 43 | Providing and fixing reinforced concrete precast kerb stone or dand R.Mtr of M-20 grade cement concrete 120 cm long having 4 Nos. bars of 8 mm dia hysd and stirrups 6 Nos of 6 mm dia as per IS with in built provision of interlocking of jointing and lifting compaction of reinforced concrete by mechanical and table vibrators jointing at site with cement mortar 1:4 complete in all respect as directed by Engineer incharge on: 100 mm thick cement concrete 1:4:8 (1 Cement : 4 Coarse sand : 8 stone aggregate 20 mm thick nominal size) including excavation of earth and cutting of BT road cutting of WBM road etc. and disposal of surplus material with all lead and lift. The size of kerb shall be (11.5+16.5)/2*30+(16.5*7.5) |
| 44 | Compacting original ground supporting subgrade 30,000.000 35.00 cum 10,50,000.00 Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300-1 and 300-2 for subgrade construction as per MoRTH Specification Clause 305.3.4 Please Enable Macros to View BoQ information |