| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m (all kinds of soil) complete all as specified and as directed. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 mtr and for all lift complete all as specified and as directed. |
| 3 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and as directed. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level complete all as specified and as directed. |
| 5 | Material and labour for steel reinforcement of RCC work including straightening, cutting, bending, placing in position and binding using TMT bars of grade Fe-500D or more below / above plinth level all complete all as specified and as directed. |
| 6 | Providnig centering and shuttering including strutting, propping etc., and removal of form work for foundations, footings, bases of columns, etc. for mass concrete, complete all as specified and as directed. |
| 7 | Providing and fixing 10mm thick multi-wall polycarbonate roofing sheet, minimum three layer structure, manufactured from virgin polycarbonate resin, having co-extruded UV protective coating on outer surface, of approved colour and transparency, fixed to MS / Aluminium supporting framework with self-drilling screws, aluminium / polycarbonate glazing bars, EPDM rubber washers, sealing tape, end caps and all necessary accessories, allowing for thermal expansion, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply and fix structural steel work riveted, bolted or welded in built up sections, built up tubular sections (round, square or rectangular) trusses and framed work in curved / straight pattern, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and as directed. |
| 9 | Providing and grouting of dowel tubes / shear keys / joints of precast members with M-60 grade cementitious grout (non shrink) of approved make by suitable means (free flowing / pump), curing etc. complete as per directions of Engineer-in-Charge. NOTE :- The payment shall be made on the basis of actual weight of approved grout injected. |
| 10 | Material and labour for painting with synthetic enamel paint to new steel surfaces and two or more coats on new work of approved brand and manufacture to give an even shade complete all as specified and as directed. |
| 11 | Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand (Zone-III) derived aggregate 40mm nominal size derived from natural from natural sources) sources : 8 graded stoneof specified grade excluding the cost of centering and shuttering as a sub base for flooring complete all as specified and as directed. |
| 12 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-Charge. |
| 13 | Demolishing cement concrete Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge.. |
| 14 | Providing and laying in position cement concrete 1:2:4 (1 Cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) complete all as specified and as directed. |
| 15 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing 1:1½:3 (1 Cement: 1½ coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) complete all as specified and as directed. |
| 16 | Material and labour for aluminium composite panels, panel shall be metallic series of approved shade for ceiling and cladding, 4 mm thick with combination of aluminium skin materials of 0.50 mm thick, aluminium sheet of alloy grade 1100H cover material coated on exposed side with PVDF (Poly vinyeldene fluoride) of KYNAR, PVDF coating containing 70% KYNAR 500 resin for antifungal and antibacterial properties and the central core shall be natural polyethylene (LDPE and HDPE) bonded to aluminium skin on both sides, and including all necessary fittings complete for finished item of work and including taking out of old Panel etc., all as per manufacturer's instructions and as directed.NOTE :- Anodised aluminium rectangular section, GI brackets etc shall be measured and paid separately under respective items of this schedule. |
| 17 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. NOTE :- (a) The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account. (b) The weight of aluminium extruded section shall be taken for purpose of payment. |
| 18 | Material and labour for Galvanised iron angular bracket , 50 x 50 x 3mm size, for fixing the rectangular channel complete all as specified and as directed. |
| 19 | Supply and fix in repairs, stainless steel alphabets letter of height upto 60cm and proportionate width hollow type, glossy / matt finished, fabricated with thickness not less than 1.80mm of stainless sheet of grade 304, including fixing and fitting arrangements at any height not greater than 12 mtr including scaffolding and staging complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Supply and fix in repairs, stainless steel organisation logo, size : 60cm to 75cm height, hollow type, (glossy / matt finished, with logo in side colour shading as per direction and approval by authority) fabricated with thickness not less than 1.80mm of stainless sheet of grade 304,including fixing and fitting arrangements at any height not greater than 12 mtr including scaffolding and staging complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 KM for all lifts, complete as per directions of Engineer-in-Charge. |
| 22 | Supply and fix circular highway lights 200 watts uniquely designed with IP lens for better lighting distribution IP-66, with 4 KV inbuilt surge protection and ingress protection of IP-66 with additional including all clamps nuts and bolts in the top of shed ceiling of approx 07 mtrs height including all T&P required for fixing complete all as specified and as directed. |
| 23 | Supply and fixing LED Luminaire 20 Watt fitting, batten type, 4' long with white powder coated housing and frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED colour temperature - 5700k, IP20, 50000 burning hours as per L70 criteria, ambient temperature - 0 to 50 Deg C, Driver efficiency >85%, THD<10%, PF>0.95, surge protection in CM-3KV, multistage isolated constant current, constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level< 60V DC as per IEC standard complete all as specified and as directed. |
| 24 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box / wooden block including connections etc. as required, complete all as specified and as directed. |
| 25 | Material and labour for submain wiring with two runs of 2.5 sq.mm single core, PVC insulated, unsheathed, multistranded copper conductor cable, 1100 volts, FRLS grade, ISI Marked, drawn through and including suitable PVC non metallic rigid conduit with accessories fixed on walls / roofs / floors / ceiling etc. and connecting terminal ends including one run of 2.5 sq.mm single core, PVC insulated, unsheathed, multi stranded copper conductor cable, green in colour, 1100 volts, FRLS grade as earth continuity conductor complete all as specified and as directed. NOTE :- Two runs of 2.5 sqmm copper cable, one run earth wire of 2.5 sqmm copper cable and PVC conduit shall be measured and paid as one RM. |
| 26 | All as per ser Item No 25.00 above but of size, 2 x 1.5 sq.mm + 1 x 1.5 sqmm earth wire.NOTE : Two runs of 1.5 sqmm copper cable, one run earth wire of 1.5 sqmm copper cable and PVC conduit shall be measured and paid as one RM. |
| 27 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 16 sq.mm 4.0 core 1100 volts grade, complete connection with proper through cable lugs complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Supply and fixing of distribution board of sheet steel enclosure, 6 way SPN, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required complete all as specified and as directed. |
| 29 | Supply and fixing SPN 40 Amps to 63 Amps rating 240V, 10KA 'C' curve, miniature circuit breaker suitable for inductive load complete testing and commissioning etc as required complete all as specified and as directed. |
| 30 | Supply and fixing SP 5A to 32A rating 240/415 V, 10KA 'C' curve, miniature circuit breaker suitable for inductive load for the existing MCB DB complete testing and commissioning etc as required complete all as specified and as directed. Please Enable Macros to View BoQ information |