| 1 | Supply |
| 2 | Supply of Bolted type Single Tension Fitting suitable for Zebra Conductor with duly made of LM-6 Aluminium Alloy complete with GI Nut and bolts and spring,plain washer.As per sample |
| 3 | Supply of Bolted type Single Suspension Fitting suitable for Zebra Conductor with duly made of LM-6 Aluminium Alloy complete with GI Nut and bolts and spring,plain washer.As per sample |
| 4 | Supply of Bolted type Single Suspension Fitting suitable for Panther Conductor with duly made of LM-6 Aluminium Alloy complete with GI Nut and bolts and spring,plain washer.As per sample |
| 5 | Supply of PG Clamp duly made of LM-6 Alluminium Alloy Suitable For Moose/Zebra with 4 Nos 16x90mm size GI Nuts and Bolts and spring & plain washer strictly as per sample. |
| 6 | Supply of PG Clamp duly made of LM-6 Alluminium Alloy Suitable For Zebra/Zebra with 4 Nos 16x90mm size GI Nuts and Bolts and spring & plain washer strictly as per sample. |
| 7 | Supply of PG Clamp duly made of LM-6 Alluminium Alloy Suitable For Zebra/Panther with 4 Nos 16x90mm size GI Nuts and Bolts and spring & plain washer strictly as per sample. |
| 8 | Supply of PG Clamp duly made of LM-6 Alluminium Alloy Suitable For Panther/Panther with 4 Nos 16x90mm size GI Nuts and Bolts and spring & plain washer strictly as per sample. |
| 9 | Bus Post Clamp Suitable For Zebra with duly made of LM-6 Aluminium Alloy complete with GI Nut and bolts and spring,plain washer.As per sample |
| 10 | Copper Bond (15mm Dia and 450mm Long with Lugs at Both End ) |
| 11 | GI Perforated Cable Tray 75 Mm |
| 12 | Supply of 75x10mm MS Flat |
| 13 | Supply of 50x6mm MS Flat |
| 14 | Supply of 25x6mm MS Flat |
| 15 | 40 mm Dia MS Electrodes of 3 Meter Length |
| 16 | Erection |
| 17 | Destringing of Jumpers of Existing Equipments 132 KV Bus Isolator, CB , CT and LA of 132 KV, 40 MVAR Cap Bank Feeder |
| 18 | Dismentalling of cable/termination of CT, CB ,BI From Control and Relay Panel of Existing 132 KV 40 MVAR Capacitor Bank Bay and New 132 KV Bay from respective trench and again laying to the new bay location and proper dressing & cleaning etc and shifting of all other asoociated material from site to work site and all other works to complete the work satisfactorily. |
| 19 | 2C x 2.5 Sq mm. unarmoured. |
| 20 | 4C x 2.5 Sq mm. unarmoured. |
| 21 | 6C x 2.5 Sq mm. unarmoured. |
| 22 | Dismentalling of Structure of Different Equipments of 132 KV 40 MVAR Cap Bank Feeder and reerection at New Location |
| 23 | Dismentalling CT, CB ,LA From Existing 40 MVAR Cap Bank Bay and shifting and re-erection to New Location safely |
| 24 | 132 KV CB |
| 25 | 132 KV CT |
| 26 | 120 KV LA |
| 27 | 132 KV 40 MVAR Cap Bank Bay & 132 KV New Bay: Termination of various sizes above laid control cable as per schedule and connection diagram ,extending DC supply from DCDB and AC supply from ACDB ,C&R panel,All Bay Equipment,CT,PT etc. including Drilling of holes wherever required ,fixing of performated cable tray ,fixing different sizes of cable gland ,ferrul,&crimping type ,lugs.including cost of required skilled material , Technician, T&P for proper completion of work as laid above as per cable schedule including making necessary holes in glands plates or box where ever required supply and fixing of cable glands of appropriate size, supply & providing ferrules & Nos for each core of cable and its termination with crimping type lugs of dowell/tension make and all other assiciated work to complete the job satisfactry |
| 28 | Erection of different type Main and auxiliary structure, columns, beams, peaks, masts ets. Suitable for placing of 132 KV Equipments. |
| 29 | Main Structure & Auxiliary Structure New 132 KV IIT Bay |
| 30 | Shifting & Erection of following equipments as per Instruction manual of various equipments and technical specification including shifting of material / equipments from store to erection site including all other associated work to complete the job satisfactorily at New 132 KV IIT Kanpur Bay. |
| 31 | 145 KV CB |
| 32 | 132 KV BI without earth switch (Motarised) including Erection of Post Insulators and proper alignment Associated Junction Box |
| 33 | 132 KV LI with earth switch (Motarised) including Erection of Post Insulators and proper alignment and Associated Junction Box |
| 34 | 132 KV TI (Motarised) including Erection of Post Insulators and proper alignment Associated Junction Box |
| 35 | 132 KV PT with Junction Box |
| 36 | 132 KV CT with Junction Box |
| 37 | 120 KV LA |
| 38 | 132 KV polycone Insulator. |
| 39 | 132 KV Line Control & Relay Panel |
| 40 | Stringing of 132 KV Bus bar with different type of conductor & span mentioned below including fitting of tension clamps, hoisting of insulators and other associated works to complete the job as per tension chart. |
| 41 | Extension of 132 KV Main Bus Bar-A |
| 42 | Jumpering of Equipments of 132 KV IIT Kanpur Bay with the help of ACSR Zebra Conductor to connect Main Bus Bar A and Bus Bar B with equipment and equipment to equipment with help of suitable clamp/connector including,cutting,bending shaping etc of the conductor as per site requirement |
| 43 | Jumpering of Equipments of 132 KV 40 MVAR Bay with the help of ACSR Panther Conductor to connect Main Bus Bar A and Bus Bar B with equipment and equipment to equipment with help of suitable clamp/connector including,cutting,bending shaping etc of the conductor as per site requirement |
| 44 | 132 KV IIT Kanpur Bay Making of shielding Mesh for 132 KV LA by fabrication of 06 Nos 3 meter long electrode with 40mm dia MS round bar having 150mm long conical shape and then its piercing vertically in the ground with top 700mm below ground level and installation in soft soil and connection jointing the electrode with 75x10 mm size MS Flat by welding for making mesh, connecting the shielding mesh with main earth mat at 2 places and finally painting the shielding mesh/ earthing strip with anti-corrosive red oxide primer and 2 coats of green paint with digging of earth trench and its back filling. Two No. risers of 75x10 mm MS Flat shall be welded with existing main earth mat to Auxiliary structure, one separate riser will be taken from laid shielding Mesh to corrosponding 3 Nos LA through surge counter for making of proper Mesh. |
| 45 | 132 KV 40 MVAR Cap Bank Bay: Making of shielding Mesh for 132 KV LA by fabrication of 06 Nos 3 meter long electrode with 40mm dia MS round bar having 150mm long conical shape and then its piercing vertically in the ground with top 700mm below ground level and installation in soft soil and connection jointing the electrode with 75x10 mm size MS Flat by welding for making mesh, connecting the shielding mesh with main earth mat at 2 places and finally painting the shielding mesh/ earthing strip with anti-corrosive red oxide primer and 2 coats of green paint with digging of earth trench and its back filling. Two No. risers of 75x10 mm MS Flat shall be welded with existing main earth mat to Auxiliary structure, one separate riser will be taken from laid shielding Mesh to corrosponding 3 Nos LA through surge counter for making of proper Mesh. |
| 46 | Earthing of main and auxiliary structure equipment.trench and panels with the help of specified size MS flat along with cutting ,bendind and straigtining of MS flat to give it proper shape Two coat if Enamel based paint of green colour above red oxide primer layer at joint ,riser strips in all sides of surface as per drawing of earthing and standard practise incuding cost of consumable material,T&P ,lobour Etc.Note:- All Equipments Earthing will be done by 75x10mm Earthing Flat from two points of Earth mat X and Y Axis, All Structure Earthing will be done by 50x6mm Earthing Flat from two points of Earth mat X and Y Axis and Cable Trench Earthing will be done by 25x6mm Earthing Flat at regular intervals. |
| 47 | 75X10mm |
| 48 | 50X6mm |
| 49 | 25X6mm |
| 50 | Opening of trench cover ,Laying and dressing of following size control cable on the cable racks in the trenches from crontrol and relay panel to various equipments for AC/DCconnection of CT.PT.CB, isolator.junction box incude shifing of cables drums from store to erection site &shifting back the balanced material to store again placing back the opened trench cover including cost of labour,.T&P,etc. to complete the work satisfactorily as per cable schedule. |
| 51 | 2C x 2.5 Sq mm. unarmoured. |
| 52 | 4C x 2.5 Sq mm. unarmoured. |
| 53 | 6C x 2.5 Sq mm. unarmoured. |
| 54 | Providing and laying of following sizes GI Pipes for Pilfer Proof Metering from CT /PT Junction Boxes etc in switch yard to Metering Cubicle Box in control room for laying of control cables through G.I. Pipes as per site requirement alongwith asoociated work such as cutting,making threads for fitting of sockets, Elbows, Dressing etc with due earthing of laid G.I. Pipe at each end |
| 55 | 1 inch Dia G.I. Pipe |
| 56 | Termination of various sizes above laid control cable as per schedule and connection diagram ,extending DC supply from DCDB and AC supply from ACDB ,C&R panel,All Bay Equipment,CT,PT etc. including Drilling of holes wherever required ,fixing of performated cable tray ,fixing different sizes of cable gland ,ferrul,&crimping type ,lugs.including cost of required skilled material , Technician, T&P for proper completion of work as laid above as per cable schedule including making necessary holes in glands plates or box where ever required supply and fixing of cable glands of appropriate size, supply & providing ferrules & Nos for each core of cable and its termination with crimping type lugs of dowell/tension make and all other assiciated work to complete the job satisfactry. |
| 57 | Other Misc. Works |
| 58 | Work of arranging electrical safety clearence which include Applying for Electrical safety clearence for above 1 No of 132 KV bay and 132 KV Panki IIT Line and 132 KV Panki-Jawaharpuram Line (Zebra Conductor) at Vidhyut Surkhsha vibhag,Uttar Pradesh Government.Then submitting the challen and fees by the contractor with all the necessary documents like electrical permits.class A form etc and other formalities and obligations to get the unconditinal Safety clearence.Contractor will be responsible for delay in final charging of bay due to non clearence of by safety department for which the firm shall .be · liable for penelties as per contract |
| 59 | Carriage of structure form EFU, Naini, Allahabad to 220 KV S/S Panki Kanpur which includes Sorting, counting, stacking and proper loading of steel structure at EFU, Naini Allahabad on the private Truck/Trailer, Safe carriage of steel strucutre from EFU, Naini, Allahabad to 220 KV S/S Panki Kanpur through private Truck/Trailer and soritng, counting,unloading and proper stacking in the premises of 220KV S/S, Panki Kanpur |
| 60 | Work of loading, safe carriage and unlaoding of any equipment, structure or any other material from any substation with in premises of 150 KM to JE store of 220KV S/S,Panki Kanpur. Every to and from carriage from 220KV S/S,Panki Kanpur will be considered as one job |
| 61 | Supply and Fixing of 150 Watt LED outdoor Flood light with associated bend pipe ISI marked Luminaries 16500-18000, 240V AC, 50 Hz Enclosure IP66 minimum Lux-110 Lumen/watt High pressure Aluminium Die cast and tempered protective toughened glass street light fitting complete of standard make ( Havells, Bajaj,Philips,CGL,Syska) Please Enable Macros to View BoQ information |