| 1 | SH-I: EI & FANS |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 3 | Group C |
| 4 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 9 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 11 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 12 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 13 | 4 X 10 sq. mm + 2 X 10 sq. mm earth wire |
| 14 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 15 | 6 x 1.5 sq. mm |
| 16 | 9 x 1.5 sq. mm |
| 17 | 3 x 2.5 sq. mm |
| 18 | 6 x 2.5 sq. mm |
| 19 | 3 x 4 sq. mm |
| 20 | 6 x 4 sq. mm |
| 21 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(i/c Requirements for CCTV, LAN & Telephone cable) |
| 22 | 20 mm |
| 23 | 25 mm |
| 24 | 32 mm |
| 25 | 40 mm |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 27 | 5/6 amps switch |
| 28 | 15/16 amp switch |
| 29 | 3 pin 5/6 amp socket outlet |
| 30 | 6 pin 15/16 amp socket outlet |
| 31 | Telephone socket outlet |
| 32 | TV antenna socket outlet |
| 33 | Bell push |
| 34 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 35 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 36 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 37 | 1 or 2 Module (75 mmX75mm) |
| 38 | 3 Module (100mmX75mm) |
| 39 | 6 Module (200mmX75mm) |
| 40 | 12 Module (200mmX150mm) |
| 41 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 42 | 3 Module |
| 43 | 6 Module |
| 44 | 12 Module |
| 45 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 46 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 47 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 48 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 49 | 4.0x16 sqmm AUG Aluminium cable |
| 50 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 51 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 52 | 8 way, Double door |
| 53 | 12 way, double door |
| 54 | 16 way, double door |
| 55 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 56 | 6 way (4 + 18), Double door |
| 57 | 8 way (4 + 24), Double door |
| 58 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 59 | Single pole |
| 60 | Single pole and neutral |
| 61 | Double pole |
| 62 | Triple pole and neutral |
| 63 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 64 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 65 | 40 amps |
| 66 | 63 amps |
| 67 | 100 amps |
| 68 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 69 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size etc as required. |
| 70 | 4.0x16 sqmm AUG Aluminium cable |
| 71 | Supplying and fixing of 4', 20W LED batten type fitting etc as reqd in addition to existing lights etc as reqd(Make:Philips/Crompton/SS) |
| 72 | ITC of 2ft.x2ft. 36W recessed Square type diffused LED light fitting (white light) so as to fit perfectly in the existing 2'x2' false ceiling suitable for operation on 230V, 50Hz AC supply etc complete as reqd |
| 73 | ITC of 9W/18W round type recess mounting diffused LED light fitting (white light) so as to fit perfectly in the existing false ceiling suitable for operation on 230V, 50Hz AC supply etc complete as reqd |
| 74 | Supplying and ITC of 400mm (16 inch),high speed wall mounted type air circulator suitable for operation on 230V, 50Hz AC supply etc compete as reqd (Usha/crompton/SS make). |
| 75 | Installation, Testing and Commissioning of ceiling fan including supplying and fixing anchor fastener , earthing etc. complete as required. |
| 76 | SITC of 300 mm sweep Exhaust fan, including wiring with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 77 | Chipping of wall, making chase for placing conduit in each room/chamber for concealed wiring for Electrical items, LAN cable, Telephone etc and finishing with cement plaster etc complete as reqd |
| 78 | SITC of 32A TPN FSU in sheet steel enclosure etc complete as reqd (in 2nd floor isolation) |
| 79 | SH-II: LAN & Telephone Wiring |
| 80 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 81 | 2 Pair |
| 82 | 4 Pair |
| 83 | Suppy, Installation, Testing and Commissioning of 16 Port Gigabit PoE Network Switch |
| 84 | Suppy, Installation, Testing and Commissioning of 24 Port Gigabit PoE Network Switch |
| 85 | Suppy & Laying of CAT 6 UTP with sleeve protector as required. |
| 86 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 87 | RJ 45 connectors along with crimping |
| 88 | RJ 45 socket |
| 89 | Telephone socket outlet |
| 90 | Supply, Installation of 4U Rack with PDU, Fan, Lock & Key, with 4 Nos power sockets etc as reqd (Make Net fox/Valrack or SS Make ) |
| 91 | SH-III: UPS power distribution arrangement |
| 92 | SITC of 32A TPN FSU in sheet steel enclosure etc complete as reqd |
| 93 | Supplying and Laying of one number XLPE insulated and PVC sheathed / XLPE AUG power cable of 1.1 KV grade of following size etc as required. |
| 94 | 4.0x10 sqmm AUG Copper cable (for UPS Incoming) |
| 95 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. |
| 96 | 4.0x10 sqmm AUG Copper cable (for UPS Incoming) |
| 97 | Supplying and Laying of one number XLPE insulated and PVC sheathed / XLPE AUG power cable of 1.1 KV grade of following size etc as required. |
| 98 | 2.0x10 sqmm AUG Copper cable (for UPS outgoingg) |
| 99 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. |
| 100 | 2.0x10 sqmm AUG Copper cable (for UPS outgoing) |
| 101 | SH-IV : SITC of MV Panel |
| 102 | SITC of floor/ wall mounting cubicle type LT panel suitable for 415V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet of 2 mm thick for frame work & load bearing members and 1.6 mm for covers & doors, 2 mm thick for gland plates, powder coated in approved shade having 200 Amps 4 strips Aluminum alloy bus bars of high conductivity with heat shrinkable coloured sleeves, DMC/ SMC bus bar supports, , entire panel shall have a common copper earth bar of size 25mm x 3 mm at the rear with 2 numbers earth stud, solid connections from main bus bars to switch gears with required size Al. bus bars and control wiring with 1.5 sq.mm PVC insulated copper conductor FRLS wires, cable alleys, cable gland plates in two halves, i/c providing following switch gears and providing necessary channel/angle iron supports of suitable size for mounting the panel etc as required as per specification as required. |
| 103 | Incoming - 125A Four pole MCCB,30KA,100-125A Thermal relese range with spreader terminal & extended rotary handle - 1No. |
| 104 | Out going - 63A Four pole MCCB,30KA,50-63 A Thermal relese range with spreader terminal & extended rotary handle- 02 Nos32A Four pole MCCB,30KA,25-32 A Thermal relese range with spreader terminal & extended rotary handle- 05 Nos |
| 105 | RYB LED Indication Lamp - 1set |
| 106 | SH-V : Service connection, Meter board & Power cables |
| 107 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (Meter box to DG set & DG set to LT Panel) |
| 108 | Above 35 sq. mm and upto 95 sq. mm |
| 109 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 110 | (i)3½ X 70 sq. mm (38mm) |
| 111 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(For earthing Neutral of DISCOM supply on consumer side to avoid voltage fluctuations in the event of Neutral break) |
| 112 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 113 | Supplying and fixing TP Sheet steel enclosure on surface / recess along with 16/25/32 A 415V \\"C\\" curve TP MCB complete with connections , testing and commissioning eetc., as required |
| 114 | Supplying and Fixing of the 3 Nos 100A Porcelain fuse cutouts (extended bus bar type ) along with neutral link on surface of wall /on existing hylum sheet etc. as required. (M/s Anchor/Bosma or equivalent make ) (1set in aerial fuse board+1 set in meter board) |
| 115 | Supplying and Fixing of the 6 mm thick hylam sheet of suitable size on surface of wall / on existing MS angles for accommodating above 3 nos 200A fuse cutouts including cutting, drilling holes etc. as required. |
| 116 | S/F of the 50mm dia ( 2.0 \\") B class GI Pipe for protecting the service cable in soil, underground, on pole etc. as required. |
| 117 | Supplying and Fixing of the flexible green coloured hose PVC pipe of 2.5 inch dia for protective cover of the cable at various locations as required. |
| 118 | S/F of the 1 inch dia flexible green colured hose PVC pipe for covering of the cables core end connections as required. |
| 119 | Providing and Fixing water proof shade for Meter Box and fuse cutouts with 20 SWG GI Sheet of size approximately 1.5 m (L ) x 0.6m (W) with suitable MS angle/MS Flat supports, grouting, necessary cement works for water leak free arrangement, painting the channels etc. as required. |
| 120 | Arranging assistance for fixing of CT type energy meter on surface of wall, liasoning with DISCOM staff , necessary inter connections, coordinating with EB authorities in releasing of LT supply etc. as required. |
| 121 | Providing end terminations with following size of Copper/Aluminum lugs as required. |
| 122 | (i) 70sqmm AL LUGS |
| 123 | Miscellaneous civil works like breaking of Cement flooring , walls , finishing works, making good the damages etc as required.( approx 5m for laying cable, GI strips etc ) |
| 124 | Supplying & fixing of the PVC Syntex Junction Box of size approx 550mm(H) x 450mm(W) x 150mm (D) with openable door on surface of wall / on existing MS angle as required. The Box should be of suitable size to fix 3 Nos 100A Palm type Fuse Cutouts with proper clearances. |
| 125 | S/F of the MS angle of size 40 mmx 40 mmx 5mm thick including cutting, bending, painting etc. as required. |
| 126 | S/F of the Heavy Duty Box Type capacitors Banks suitable for operation on 415V, 50 HZ AC Supply as required.( M/s L&T LTBCH or similar sup make) |
| 127 | SH-VI : Earthing for electrical installations and DG set |
| 128 | Providing Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. ,(but without charcoal/ coke and salt) as required. ( For DG neutral and body) |
| 129 | providng & Fixing 25mm x5 mm GI strip in 40mm dia GI pipe from earth electrode including connections with GI nut , bolt , spring washer excavation and refilling etc., as required |
| 130 | supplying & Fixing of 25mm x5 mm GI strip on surface / in recess for extension of earth connections as required Please Enable Macros to View BoQ information |