| 1 | Dismantling of brick tiles single layer as in roof covering complete all as specified |
| 2 | Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) and washing the surface thoroughly to remove all mud complete all as specified. |
| 3 | M & L brushing neat cement slurry with 3kg of cement per sqm complete all as specified |
| 4 | M&L for P.C.C 1:2:4 type B0 using 12.50 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 5 | M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stilL green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed. Note :- Water proofing compound shall be measured separately. |
| 6 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 7 | M&L applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces |
| 8 | S&F APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified |
| 9 | M & L 40mm thick Brick tiles laid on bedding layer of CM 1;3 15mm thick and joints grouted flush in cement mortar 1:3mixed with 5% of crude oil by weight of cement over APP membrane complete all as specified and directed. |
| 10 | M & L 40mm thick Brick tiles laid on bedding layer of CM 1;3 15mm thick and joints grouted flush in cement mortar 1:3mixed with 5% of crude oil by weight ofcement over APP membrane except tiles complete all as specified and directed. |
| 11 | M & L flush pointing in CM 1:3 to brick tiles laid flat in roof or paving incuding raking out joints complete all as specified and directed. |
| 12 | Taking up or down existing steel 15 mm tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed |
| 13 | Taking up or down existing steel 20 mm tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed |
| 14 | Supplying, fixing, 15 mm jointing and testing galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 15 | Supplying, fixing, 20 mm jointing and testing galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed |
| 16 | Dismantling of water tanks (PVC/RCC of any description) exc 250 ltr and n.exc 500ltr capacity and removing from site complete all as specified and as directed. |
| 17 | S&F 500 ltr capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 18 | M&L (Except Tank) 500 ltr capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 19 | S&F in repairs 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed. |
| 20 | S & F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 21 | S & F in repair 15 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 22 | Demolition and breaking up drain pipes AC/PVC pipe in event n.exc 150 mm dia including all fittings. |
| 23 | S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed |
| 24 | S&F 110 mm bore PVC (SWR) bends in any radius complete all as specified and directed. |
| 25 | S&F PVC (SWR) junction single (single tee) equal or unequal, dia of pipe 110 mm complete all as specified and directed. |
| 26 | S & F 75 mm bore PVC (SWR) pipe of pressure rating 4kgf/cm2 single socketed in any length with rubber ring joints jointing with adhesive fixed in repair to wall/laid in trenches complete all as specified and directed. |
| 27 | S&F 75 mm bore PVC (SWR) bends in any radius complete all as specified and directed. |
| 28 | S&F PVC (SWR) junction single (single tee) equal or unequal, dia of pipe 75 mm complete all as specified and directed. |
| 29 | S&F 75mm dia PVC (SWR) floor trap with grating including joining to waste pipe fixed in solvent cement incl taking down damaged floor trap in any position complete all as specified and directed. |
| 30 | Taking down cement plaster of any description any thickness /dado/Skirting/ including raking out joints hacking for key scrubbing down with water all as specified. |
| 31 | Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excludding precast concrete articles all as specified. |
| 32 | M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:6all as specified. |
| 33 | M&L for 15 mm thick cement mortar 1:4 on brick or concrete surface finished even and smooth without using extra cement all as specified |
| 34 | M&L for preparing new plastered or unplastered wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)all as specified and directed by Engr-in-charge. |
| 35 | M&L for complete removal of existing treatments on wall surfaces and applied two coat of weather coat over one coat of primer all as specified and directed by Engr-in-charge. |
| 36 | M&L for 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement all as specified |
| 37 | M&L for preparing surfaces new plastered surfaces of walls by applying two coats of oil bound distemper over a coat of 1mm thick wallcare putty on plastered surface preparatory to distempering complete all as specified. |
| 38 | M&L Complete removal of existing treatment of wall surfaces applying two coat of oil bound distempering over a coat of wall care white putty on plastered surface all as specified and directed by Engr-in-Charge. |
| 39 | M&L Plastering 5mm thick in cement mortar (1:3) finished even and smooth without using extra cement as on ceiling complete all as specified |
| 40 | M & L for preparation of new plastered surfaces of Ceilings and applying three coats of white wash etc. complete all as sepcified and directed |
| 41 | M & L for preparation of old plastered surfaces of ceilings and applying two coats of white wash etc. complete all as sepcified and directed |
| 42 | M & L for preparation of old plastered surfaces of walls (for washrooms) and applying two coats of white wash etc. complete all as sepcified and directed |
| 43 | S&F in repairs vitreous China wash down water closet pan (pedestal pattern) white including bolts, flushpipe of polyethylene of low or high density or PVC 32 mm dia anti syphonage pipe etc complete |
| 44 | Supply and fixing plastic water closet seat cover white closed patern with flat bottom and cover and mild steel chromium plated or aluminised hinging devices |
| 45 | S & F S&F PTMT chromium plated health faucet Cat Part No: ALD -565 for pedestal pattern water closet including PVC flexible pipe along with complete necessary fittings complete all as specified and as directed. |
| 46 | S&F looking mirror size 600x450mm of selected quality fixed on wall with ,aluminum frame 5.5mm thick etc. back side Acrylic sheet. |
| 47 | Supply and fixing in replacement chromium plated grating 125mm dia circular fixing with cement mortar 1:3 on nahani trap/floor trap complete all as specified and directed. |
| 48 | S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm |
| 49 | M&L for 25 mm thick granite machine cut as incooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over bedding layer or screed 15 mm thick screed bed in cement mortar 1:4 including cutting , grinding, rounding edges, rubbing and polishing complete all as complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in repair Stop valve (Concealed) ,15 mm cast copper alloy with long shank &cup with capstan heads, screwed down, high pressure, with crutch or butterfly handle screwed for 15mm bore iron fixed fancy type complete. |
| 51 | S&F in repair 15mm angular stop valves, fancy type chromium plated, with long shank and cup screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed . |
| 52 | S&F in repair Bib tap fancy type (Long body) cast copper alloy suitable for 15mm bore iron pipe with long body fancy type complete fixed in repairs . |
| 53 | S&F PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe 10 Ltr capacity complete all as specified fixed in repairs. |
| 54 | S&F connection pipe braided with wires (reinforced) 45cm long with brass check nut and PVC washers at both ends complete all as specified and directed. |
| 55 | S&F brass chromium plated shower rose of 150 mm size (Square shape) and 450 mm long CP arm, with or without swivel joints including fixing to steel pipe or union all as specified and directed by Engineer - in - Charge. |
| 56 | S&F Brass chromium plated tubular tower rail 20mm dia , D type, 60cm long between flanges complete |
| 57 | S&F Brass CP Soap dish, any type, fixed to plugs with chromium plated brass screws all as specified and directed. |
| 58 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as specified. |
| 59 | S&F powder coated aluminium frame for doors,windows, partitions ,ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 60 | S&F powder aluminium window and ventilator shutters without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 61 | M&L for sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane. |
| 62 | S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks. |
| 63 | S/F PVC solid door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinfoced with MS square tube, suppling and fixing in opening as per specification and drawing. |
| 64 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisiting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing. |
| 65 | Supply & Fixing 100mm size stainless steel butt hinges heavy grade extruded stainless steel hinge plate complete all as specified. |
| 66 | S&F Aluminum anodized barrel tower bolt of extruded section of size 150mm complete all as specified. |
| 67 | S&F extruded Aluminum alloy handle fabricated of size 150mm all as specified and directed |
| 68 | Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and disposal of rubbish outside MD land complete all as specified |
| 69 | Given sunken floor shall be treated as per following instructions and directed by Engr in Charge :-(A) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or miling to remove cement laitance, existing coatings and achieve a gripping profile that is clean dry and free from laitance and any other form of surfece contamination. The installation instructions n manufacturer's published literature should be strictly complied with, includingf but not limited to the following:-(aa) Chipping out any visible cracks in \\"V-Groove\\" pattern as applicable. Special attention on this part. Cleaning of cracks and then filling those cracks with SIKA latex SBR 100 putty/Dr fixit 302 SBR latex/ Perma Latex SBR/ FOSROC Nitabond SBR latex/ Asian Paints latex as required. Final cleaning of surface with power grinder, Wire brush, hair brush & vacuum pressure if required.(bb) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of SIKA Top Seal-107/ Brush bond FOSROC/ DR Fixit/ STP/CICO.(cc) Whilist the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of SIKA Top Seal-107/ Brush bond FOSROC/ DR Fixit/ STP/CICO of viscosity as per manufacturer's instructions.(dd) Apply glass febric sheet of Sika Fab 1/FOSROC/ DR Fixit/ STP whilist the first coat is wet.(ee) Once touch dry, apply second coat of Acrylic modified Cementitious coating of SIKA Top Seal-107/ Brush bond FOSROC/ DR Fixit/ STP/CICO of viscosity as per manufacturer's instructions on the entire area.(ff) Second coat shall be applied 6-8 hours of application of previous coat and in the direction right angle to the previous coat.(gg) The waterproofing coating should be taken to a height minimumn300 mm above the finished floor level on the vertical surface.(hh) It is essential to cure Acrylic modified Cementitious coating immediately after application (minimum 6-8 hours drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. |
| 70 | A protection plaster 15mm thick in CM 1:3 admixed with appropriate Integral water proofing compound has to be applied on the walls.Admixture : SIKA Plastocrete Plus/FOSROC/ DR Fixit/ STP/CICO confirming to IS 2645. |
| 71 | Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika Plastocrete over the applied water proofing coating on horizontal surface.Admixture : SIKA Plastocrete Plus/FOSROC/ DR Fixit/ STP/CICO confirming to IS 2645.(a) All the corners and joints should be pretreated with an elastic waterproofing sealing tape withy a wooven bonding mesh on each surface ab=nd an elastic expansions zonbe in the centre of Make Sika Seal Tape S/FOSROC/ Dr Fixit/ STP.(b) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(c) Waterproofing/Sunken floor treatment has to be carried out through applicators authorised by the respective manufacturers and approved by GE. |
| 72 | M & L 25mm thick cement concrete flooring type B-1, 1:2:4, using 20 mm graded stone aggregate finishing cement concrete surface even and smooth without using extra cement. |
| 73 | M& L Cement concrete type E-2, 1:5:10 using 40mm graded aggregate in foundations filling and mass concrete as in sunken floor. |
| 74 | M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or colored cement to match over and incl 15mm thick bedding layer CM 1:6 complete all as specified. (Colour and shade as approved by Engr-In-Charge) |
| 75 | M&L for coloured glazed tiles of size 450x300x7 mm thick in dados set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4 complete all as specified and directed. (Colour and shade as approved by Engr-In-Charge) |
| 76 | M&L for 50mm PCC 1:3:6 type C1 using 20mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth without using extra cement all as specified. |
| 77 | Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed. |
| 78 | M&L for repairing of R.C.C projections, chajjas, roofs, facia etc by necessary preparation. Scarpping, cutting, chiseling derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.,C.C surfaces with cement concreat (1:1.5:3) using 12.5mm graded crushed stone aggrigates and reinforcement with welded mesh (If Reqd) of weight exc 2 kg per sqm but n.exc 3kg/sqm with or without facia and finished with cement and sand motar (1:3) using coarse sand and work in patches area n.exc 5 sqm each and thickness of R.C.C member n.exc 70mm including necessary form work and applying two coats of finishes to match with the existing surfaces in at any height complete all as specified and directed by Engr-in-charge. (Note : Welded mesh included in this item) |
| 79 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc for shafts, wells, cesspits , manholes pier holes, laying of UG cable etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 80 | Material and labour for cement concrete foundation 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and under floor as sub base etc., complete |
| 81 | M&L for PCC 1:2:4 type B-1(using 12.50 mm graded stone aggregate) as in channels/benching of manhole, drain,laid to shape and slope and surfaces finished even and smooth using extra cement, complete including all form work etc all as specified and directed. |
| 82 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cms in soft /loose soil. |
| 83 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed. |
| 84 | S&F of RCC pipes, class NP-3 laid and jointed complete with collars of 450 mm dia and testing complete |
| 85 | M & L TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending, spirally for columns hooking ends binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 86 | M&L mild steel TMT bars 6mm to 8mm dia cut to length , bent to shape required, including cranking, bending spirally for stirrups and binding with and incl mild steel wire (annealed) not less than 0.9mm dia Complete all as spcified and as directed. |
| 87 | M & L for formworks to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 88 | M&L reinforced cement concrete 1:2:4 type B1( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. |
| 89 | M & L for 25mm thick Sand cushioning under paver block complete all as specified and directed. |
| 90 | M&L machine pressed precast coloured concrete coloured interlocking paver blocks any shape and size confirming of IS 15658: 2006 of 60mm thick , M-35 laid and jointed with grey cement and pigment complete all as spd and directed. |
| 91 | M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed. |
| 92 | Dismantling wrought iron or mild steel work of any description not otherwise provided all as specified. |
| 93 | S&F for ornamental and intricate designFramed work such as gates, grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 94 | M&L for Preparing and applying one coat of red oxide primer and two coats of synthetic enamel paint over new steel Surfaces of any description, over 10cm in width or girth |
| 95 | S&F 2 mm thick Fibre glass reinforced translucent sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc |
| 96 | Material and labour for Granite (of any type) work 20mm thick machine cut (table rubbed and polished) in steps jambs, pillars, window cills, cooking platforms, shelves in cupboard, handwash places and like including necessary cutting and grooving to walls and making good including 10mm thick in cement mortar (1:3) screed bed or bedding layer and pointing with cement mortar (1:2) with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 97 | Taking down carefully existing point wiring of any type (i.e on wooden batten, surface conduit, casing capping or concealed conduit except existing conduit) complete for light, fan, socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc, complete all as specified and directed. |
| 98 | Taking down sub main wiring of two single core PVC cable PVC insulated 4 / 6 sqmm including conduit or wooden batten and remove from the site of work and making good the disturbed surfaces of wall or floor etc. as directed by Engineer-in-Charge. |
| 99 | Taking down main switch / DB and making good the disturbed surface as directed by Engineer-In-Charge. |
| 100 | M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet one light / fan / call bell point controlled by one, one way switch.all as specified.a) One light / fan / call bell point controlled by one, one way switch all complete as specified and directed. |
| 101 | All as per item No 100 above but for 5 amps socket on independent board all complete as specified and directed. |
| 102 | All as per item No 100 above but for 5 amps socket on same board all complete as specified and directed. |
| 103 | All as per item No 100 above but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board all complete as specified and directed. |
| 104 | Supply & fixing switch piano flush type single pole one way 5 Amps all as specified. |
| 105 | All as per item No 104 above but single pole 5 Amps two way all as specified. |
| 106 | Supply & fixing switch piano flush type single pole 15 Amps all complete as specified and directed. |
| 107 | Supply & fixing socket outlet 5 Amp flush button type all as specified. |
| 108 | All as per item No 107 above but 6 pin 5/15 Amps multi type all complete as specified and directed. |
| 109 | Supply & fixing switch piano single pole bell push all as specified. |
| 110 | Supply & fixing bell electric (dingdong) 230 volt, SP all complete as specified and directed. |
| 111 | Supply and fix ceiling fan regulator Electronic rotary Step type single phase A/C 230 volts all complete as specified and directed. |
| 112 | Supply and Fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size, complete all as specified. |
| 113 | S & F lamp holder, PVC / polycarbonate type insulated body with back plate suitable complete all as specified and directed. |
| 114 | S & F LED lamp 9 watt polycarbonate complete all as specified and directed. |
| 115 | Supply & fixing decorative wall light fixture made up of polycarbonate/glass all as specified and directed. |
| 116 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type |
| 117 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type |
| 118 | S & F sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 12 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection complete all as specified and directed. |
| 119 | Supply and fix MCCB 100 Amps 4 pole 415 Volt,25 KA breaking capacity |
| 120 | Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars, Neutral links, blanking plates |
| 121 | M & L for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unUNSHEATED cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. Note : Two runs of 6 sqmm PVC FRLS multi stranded copper cable wire and One run of 6 sqmm PVC FRLS multi stranded copper cable earth wire and One run (01 meter) PVC conduit of suitable size ISI mark will be measured and one unit length. |
| 122 | Supply & fixing of 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 123 | Supply & fixing of 14 Watt Batten luminaire with Polycarbonate Housing with high quality extruded polycarbonate diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and an outstanding System efficacy of at least 150 lumen/watt and maximum system wattage of 14 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 124 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 125 | S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed. Please Enable Macros to View BoQ information |
| 126 | S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed. Please Enable Macros to View BoQ information |