| 1 | Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of DI/GI water tubing and getting out in any type of soil complete all as specified and directed. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed. |
| 4 | Taking out G I pipe 15 mm dia fixed on wall in existing position and removing from site all as specified and directed by Engineer-in-charge. |
| 5 | Supply and laying for 15 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 6 | Taking out G I pipe 20 mm dia fixed on wall in existing position and removing from site all as specified and directed by Engineer-in-charge. |
| 7 | Supply and laying for 20 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 8 | Taking out G I pipe 25 mm dia fixed on wall in existing position and removing from site all as specified and directed by Engineer-in-charge. |
| 9 | Supply and laying for 25 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 10 | Taking out G I pipe 50/40 mm dia fixed on wall in existing position and removing from site all as specified and directed by Engineer-in-charge. |
| 11 | Supply and laying for 40 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 12 | Supply and laying for 50 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 13 | Material & labour for taking out old CI/GI Pipe 100mm dia from trenches and removing from site. |
| 14 | Material & labour for taking out old CI/GI Pipe 80mm dia from trenches and removing from site. |
| 15 | Supply and laying for 100 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply and laying for 80 mm bore dia of Galvanised iron tubing \\"Medium grade\\" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union complete all as specified and directed by Engineer-in-charge. |
| 17 | Taking up CI/DI/GI of size 150/200mm water mains (including all fittings), with spigot and socket ends and lead joints including burning out as directed and specified by Engr-in-charge. |
| 18 | Supply and Lay Ductile iron pipe 150 mm dia, CML, tyton with spigot and socket ends centrifugally cast, Class K-7, in any length, laid in trenches at various location as directed and specified by Engr-in-charge.Note:- (i) Rates to be deemed including joint of DI pipe with compression of a rubber gasket between a seating on the inside of the socket and the external surface of spigot etc. and DI pipe with all incl fittings.(ii) Sub connection making with suitable existing size lees |
| 19 | Material and Labour for DI/CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of upto 150 mm bore dia size confirming to IS: 1538-1993 complete all as specified and as directed. |
| 20 | Supply and fixing in replacement cast iron sluice valve suitable for 150mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking down complete all as specified & directed. |
| 21 | Supply and fixing in replacement cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking down complete all as specified & directed. |
| 22 | Supply and fixing in replacement cast iron sluice valve suitable for 80mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking down complete all as specified & directed. |
| 23 | Material & labour for taking out in location in existing position U/S Titon joint, including fixing of new Titon joint 150 mm dia complete with both ring and all nut & bolts including rubber geskit. |
| 24 | Material & labour for taking out in location in existing position U/S Titon joint, including fixing of new Titon joint 100 mm dia complete with both ring and all nut & bolts including rubber geskit. |
| 25 | M & L for repairs of CI sluice valve 80 mm bore including replacement of locking nut with GI Nut and bolts of suitable size, greasing and refixing after repair including refacing, regrinding, lathe and machine, threading work & fitted with gasket gland rope & nut bolt of suitable size and testing,complete all as specified and directed by Engineer-in-charge. |
| 26 | M & L for repairs of CI sluice valve 100 mm bore including replacement of locking nut with GI Nut and bolts of suitable size, greasing and refixing after repair including refacing, regrinding, lathe and machine, threading work & fitted with gasket gland rope & nut bolt of suitable size and testing,complete all as specified and directed by Engineer-in-charge. |
| 27 | M & L for repairs of CI sluice valve 150 mm bore including replacement of locking nut with GI Nut and bolts of suitable size, greasing and refixing after repair including refacing, regrinding, lathe and machine, threading work & fitted with gasket gland rope & nut bolt of suitable size and testing,complete all as specified and directed by Engineer-in-charge. |
| 28 | M & L for repairs of CI sluice valve 200 mm bore including replacement of locking nut with GI Nut and bolts of suitable size, greasing and refixing after repair including refacing, regrinding, lathe and machine, threading work & fitted with gasket gland rope & nut bolt of suitable size and testing,complete all as specified and directed by Engineer-in-charge. |
| 29 | M & L for repairs of CI sluice valve 250 mm bore including replacement of locking nut with GI Nut and bolts of suitable size, greasing and refixing after repair including refacing, regrinding, lathe and machine, threading work & fitted with gasket gland rope & nut bolt of suitable size and testing,complete all as specified and directed by Engineer-in-charge. |
| 30 | Material & Labour for taking out unservisable submersible pumpset(alogwith submersible motor)of any capacity & make,including delivery pipe 40/50 mm bore,flanged/Socket GI tubing (Average 3/6 meter long each pipe), from borewell depth Upto 150 meters, and including lowering the same after repairs of pumpset all as directed by Engr-in-Charge. Note:- (i) Rates are deemed for making flanged/MS Socket joints with rubber washers and replacement of rusted nuts,bolts in work etc all as directed by Engineer-in-charge. |
| 31 | Disconnecting and taking out old unsv gate valve and S& F Gun Metal globe/ gate valve/Ball Valve with iron wheel head or handle screwed both ends of following sizes:- |
| 32 | 15 mm bore pipe |
| 33 | 20 mm bore pipe |
| 34 | 25 mm bore pipe |
| 35 | 40 mm bore Pipe |
| 36 | 50 mm bore Pipe |
| 37 | Material & Labour for carring to work shop U/S submersible & monoblock motor (water cooled or oil cooled) & pump including cutting U/S winding , removing insulating material, cleaning and rewinding with PVC insulated 1100 volts grade single core copper conductor as per IS 694 winding wire of appropriate size/gauge as per existing , providing insulting mterial of superior quality , supply & replace thrust bearing , assembling the motor complete , including coupling with multistage pump , jointing & connecting with submersible cable and testing at site for following HP of any make : |
| 38 | 2.00 HP to 5 HP |
| 39 | 7.5 HP to 10 HP |
| 40 | 12.50/15.00 HP |
| 41 | 37.5/50.00 HP |
| 42 | Material & labour for rectifing the external water supply sudden faults/breakdown i.e blockage, leakage, brust of pipe including taking down of existing GI/DI/CI cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position,all required fittings e.g. union, socket, nipple, tee,reducer, flange ,rubber gaskit,elbow, titon joint fittings etc. of following sizes.Note :- Excavation of Earth work shall be measured and paid seperately. |
| 43 | 15mm to 20mm bore pipe |
| 44 | 25mm to 40mm bore pipe |
| 45 | 50mm to 80mm bore pipe |
| 46 | 100mm bore pipe |
| 47 | 150mm bore pipe |
| 48 | 200mm bore pipe |
| 49 | 250mm bore pipe |
| 50 | Repair of pump motor starter of any type & capacity by decarbonizes of contact point, tightening of electric cables and replacement of unserviceable part and complete testing after repair as directed. |
| 51 | Taking down galvanised water tubing and fittings from Wall/Ceiling/Floor/Trench, including cleaning and refixing of following sizes:- |
| 52 | 15mm bore Pipe |
| 53 | 20mm bore Pipe |
| 54 | 25 mm bore pipe |
| 55 | 40/50 mm bore pipe |
| 56 | Supply & fixing in repair Ball valves of size 20 mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) (Make : Prayag/Polytuff/Pearl) |
| 57 | Supplying and laying including taking down of UPVC/CPVC pipes of size 20 mm including all fittings such as elbow,union,tee,socket,etc on walls/ceiling or laying in floors complete all as specified and directed. |
| 58 | Supplying and laying including taking down of UPVC/CPVC pipes of size 25 mm including all fittings such as elbow,union,tee,socket,etc on walls/ceiling or laying in floors complete all as specified and directed. |
| 59 | Cleaning of UG (under ground) sumps incl scraping of walls, bottom and mouth of circulating pipe (incoming, outgoing, interconnecting and overflow pipes) and removing the accumulated dirt in form of mud & deposited salts on bottom & walls sump by manullay/mechanically & cleaning the sump by fresh water and finally giving single coat of cement wash on inner surface of the walls & bottom of the sump and painting /writing of date of cleaning all as directed by Engr-in-Charge for the following capacities of sumps :- |
| 60 | UG sump 100000 Gallons capacity at Main Pump House No -01 |
| 61 | Sump 60000 Gallons capacity at Hill Top |
| 62 | Sump 40000 Gallons capacity at Hill Top |
| 63 | Supply, laying and connecting submersible cable water proof flat 3 core copper conductor PVC insulated & PVC sheathed 1100 Volts grade 4 Sqmm as per IS-694 for subemrsible pumps. |
| 64 | Supply, laying and connecting submersible cable water proof flat 3 core copper conductor PVC insulated & PVC sheathed 1100 Volts grade 6 Sqmm as per IS-694 for subemrsible pumps. |
| 65 | Supply, laying and connecting submersible cable water proof flat 3 core copper conductor PVC insulated & PVC sheathed 1100 Volts grade 25 Sqmm as per IS-694 for subemrsible pumps. |
| 66 | Repairs of water supply installation electric panels by checking electric connections & replace unsv lugs with new lugs, copper wire etc and testing & replacement of following items:- |
| 67 | 3 Phase selector switch |
| 68 | 3 phase indicator lamp (RYB) |
| 69 | Replace existing Volt Meter with digital voltmeter for 3 |
| 70 | Replace existing 3phase Amp meter with digital Amp meter |
| 71 | Material and Labour for preperation of old iron surfaces of any description and applying two coat of synthetic enamel paints over a coat of zinc chrome priming paints as per existing colour or directed by Engr-in-charge. |
| 72 | Repairing of existing valve pit chamber of any size by re-plastering, finishing & whitewash/painting of chamber cover and cleaning of surrounding area including removal of unserviceable material from site all as directed. |
| 73 | Material and Labour for cutting existing road/hard standing 40 cm wide including necessary excavation and earth work for taking out/laying pipe and making good disturbed surfaces to match with existing complete all as specified and as directed. |
| 74 | M & L for two coat of synthetic enamel paint on distribution pipe line all as per specified and directed by Engr-in-charge. Make : Burger/Asian |
| 75 | Supply TCC90A for swimming pool |
| 76 | Supply Alum for swimming pool & Pump house no -01 |
| 77 | Supply Blue vitreoul(Copper sulfate) for swimming pool |
| 78 | Supply Bleaching Powder for pump house no - 01 |
| 79 | Material & Labour for cleaning of swimming pool size Aprox 5.5 lakh litter capacity and balancing tank, removing complete dust and dust removing scale from wall, floor and desk area tiles with and including requried chemicals etc carefully all as par directed by Engr-in-charge |
| 80 | Material & Labour for Buffing and polishing on stainless steel railing , Hand rail, Veritcal & Horizontal bar up 50mm dia complete all as par directed by Engr-in-charge and the following staps are should be followed :- Frist step:- Clean and prep the stainless steelSecond Step :- Buff the stainless steel Third Step:- Polish the stainless steel |
| 81 | M&L bailing / draining out of water, taking out deposited sludge, cleaning of internal surfaces by using steel wire brushes and complete removal of debris to a distance minimum 50 mtr away from over head tank etc of Overhead tank out and Painting to raising/deleivery/wash out/over flow CI/GI pipe line 150 mm dia Over Head reservoir (RCC) as per existing colour (Apex) code including preparation of old surface of painting with one coat of synthetic enamel paint from ground level to bottom of the dome of the tank complete removing all scale & dirt from bottom & walls and from mouth of circulation pipes of overhead tank of capacity of following size at staging height exceeding 15 metre and not exceeding 30.00 metre and disinfecting chemical the same using disinfecting chemical (chlorine) complete all as specified & directed.Note :- The rate quoted shall be deemed to include the cost of neccessary scaffolding,supports,all type of cleaning material etc.Appx paint for RCC tank & structure and inlet & outlet pipe syenthic enamel paint and insurance of workers. |
| 82 | RCC overhead Tank/Reservoir of capacity 1 lakh gallon |
| 83 | RCC overhead Tank/Reservoir of capacity 50 thousand gallon |
| 84 | Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01/Pump House No-2 / User End/ Sajjan Line Over head tank as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01 at main Gate as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine Please Enable Macros to View BoQ information |