| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar or lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 3 | Excavation over area not exceeding 1.5m deepand getting out in any type of soil complete all as specified and directed. |
| 4 | Excavation over area depth exceeding 1.5 metre but not exceeding 3.0metre and getting out in any type of soil complete all as specified and directed. |
| 5 | Excavation over area depth exceeding 3.0 metre but not exceeding 4.50 metre and getting out in any type of soil complete all as specified and directed. |
| 6 | Excavation over area depth exceeding 4.50 metre but not exceeding 6.00 metre and getting out in any type of soil complete all as specified and directed. |
| 7 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. |
| 8 | Removing excavated material n.exc 50m and depositing where directed at a level nexc 1.5mtr above the starting point complete all as specified and directed. |
| 9 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished and reforming benching as required for 150mm dia of pipe complete all as specified and directed. |
| 10 | M & L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 and external pointed flush in same mortar as the work proceeds. complete all as specified and directed. |
| 11 | All as per item No 10 here-in-before, but except bricks. complete all as specified and directed. |
| 12 | Material and labour for plain cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 13 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.(Note: WPC shall be measured and paid seperately). |
| 14 | Supply only integral water proofing compound complete all as specified and directed. |
| 15 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 16 | M & L for broken bricks loose filling with aggregate of gauge 80 to 150mm as in soakage well complete all as specified and directed. |
| 17 | M&L for Precast Cover Slab, Gray Steel Fiber reinforced concrete 600x600mmx75mm Medium duty solid cover with frame complete all as specified and directed. |
| 18 | M&L for Precast Cover Slab, Gray Steel Fiber reinforced concrete 750x750mmx75mm Medium duty solid cover with frame complete all as specified and directed |
| 19 | M & L Reinforced cement concrete M-25(Design mix) using 20mm graded crushed stone aggregate in slabs/ shelves complete all as specified and directed |
| 20 | steel Form work to soffit of suspended slab such as roof slabs floor slab, laidings and similar work not exceeding 200mm thick complete all as specified and directed |
| 21 | M&L Plain Cement concrete M-7.5 (Nominal mix), (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concreting complete all as specified and directed. |
| 22 | M&L for concrete bed to drain pipes for 150mm bore pipes including packing under and hunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed |
| 23 | M&L for Reinforced concrete pipes 150mm dia, class NP-3 with one collar per length of pipe laid and jointed on concrete bed, complete including testing etc (concrete bed shall be measured and paid for separately) complete all as specified and directed. |
| 24 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed complete to walls or laid in trenches complete all as specified and directed. Please Enable Macros to View BoQ information |