| 1 | Demoliton of brick work built in cement mortar as in drain, manhole, septic tank and soak well complete all as specified and directed. |
| 2 | Demolition and breaking drain pipe (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipe size of pipe 100mm |
| 3 | Demolition and breaking drain pipe (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipe size of pipe 150mm |
| 4 | Demolition and breaking drain pipe (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipe size of pipe 300mm |
| 5 | Demolition of cement concrete in ground floors and paving n. exc 15 cm thickness below or above ground level complete all as specified and as directed. |
| 6 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. |
| 7 | Description same as per item No 4 above, but exceeding 1.5 M and not exceeding 3.0M in depth and getting out in any type of soil complete all as specified and as directed. |
| 8 | M & L PCC 1:3:6 type C-2 using 40 mm stone aggregate as in foundation filling and mass concrete as in man holes septic tank soak well and drain complete all as specified and as directed. |
| 9 | M&L for Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed size of pipe 150 mm dia |
| 10 | M&L for Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed size of pipe 200 mm dia |
| 11 | M&L for Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed size of pipe 300 mm dia |
| 12 | M&L for Reinforced concrete Bends, class NP3, laid and jointed complete all as specified and as directed size of pipe 200 mm dia |
| 13 | M&L for Reinforced concrete Bends, class NP3, laid and jointed complete all as specified and as directed size of pipe 300 mm dia |
| 14 | M & L 150 mm internal dia of pipe cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate. |
| 15 | M & L 200 mm internal dia of pipe cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate. |
| 16 | M & L 300 mm internal dia of pipe cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate. |
| 17 | M & L brick work using sub class ‘B’ bricks old size straight or curved on plan exc 6.0 M mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 18 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 19 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 20 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed |
| 21 | M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces, mixed with water proofing compound, surface finished even and smooth without using extra cement complete all as specified and as directed.Note:- Water proofing compound shall be measured separately as supply only in appropriate item. |
| 22 | M & L PCC 1:3:6 type C-1 using 20 mm graded store aggregate as in coping including use and waste of form work where necessary complete all as specified and as directed. |
| 23 | S & F mild steel rungs made out of 16 mm dia round bars made to shape complete all as specified and as directed. |
| 24 | Supply only water proofing compound. |
| 25 | M&L precast Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in cover slabs for man holes/Septic tank/Soakage well etc set in cement mortar 1:6 including necessary form work complete all as specified and directed. |
| 26 | S&F TMT steel bars 10 mm dia and above cut to length bent to shape, required including cranking benchings spirally hooping for colums hooking ends and binding with and including mild steel wire annealed) not less than 0.9mm dia |
| 27 | Cleaning of manholes/Septic tank/Soakage well of depth n. exc. 1.5 M deep mechanically or manually by taking off sludge waste soil and silted soil from the existing manhole of any size and removing the sludge to a distance n. exc. 2.00 KM in sealed container and depositing the same all as specified and directed |
| 28 | M&L Cement concrete type C-2 , 1:3:6 ( Using 40 mm graded stone aggregate foundations, filling and mass concrete |
| 29 | M & L for 25mm thick Sand cushioning under paver block complete all as specified and directed. |
| 30 | M&L machine pressed precast coloured concrete coloured interlocking paver blocks any shape and size confirming of IS 15658: 2006 of 60mm thick , M-35 laid and jointed with grey cement and pigment. |
| 31 | M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed. |
| 32 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 300 mm internal dia of pipe |
| 33 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm |
| 34 | M & L for Cement Concret type D-2, 1 :4 :8 (40 mm graded stone aggregate) as in foundations, filling and mass concrete complete. |
| 35 | M&L for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165. |
| 36 | S& F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550MPa asin roof covering/cladding to wall with self tapping screws complete as as specified and directed. |
| 37 | M&L Preparation new steel surface and iron surfaces of any description, not otherwise described, over 10 centimetre width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed. Please Enable Macros to View BoQ information |