| 1 | Supply, Installation Testing & Commissioning of (05) Passenger (G+3) MRL lift at Transit accommodation in Machbhawan Anantnag. The lift shall be suitable for (05) passengers of standard design having speed of 1 m/s serving from Ground, 1st, 2nd & 3rd floor i.e. 04 stops and 04 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards.• Machine – Elevator shall have its own driving machine. Gearless machines located in the shaft on the top of guiderails. The method of drive shall be Electric gearless Traction with motor having VVVF Control. The construction of Elevator machines shall conform to IS-14665 2.2 Motor.• Power Supply – 400/415 V (3 Phase AC)• Control – Simple Collective Selective Control (VF regenerative drive)• Available Hoist way dimensions – 1800 mm (W) x 1400 mm (D)• Overhead - 4200mm• Required Pit depth - 1350mm.• Landing door – Telescopic opening door in stainless steel hairline.• Door opening: Ground, Ist, 2nd & 3rd floor on same side• Car design - stainless steel in hairline finish.• Handrail - round handrail in stainless steel finish provided on rear wall of car.• Alarm button in car operating panel with battery back-up.• Automatic operation for car fan.• Anti-nuisance (empty car)• Anti-nuisance (car call cancellation at direction reversal)• Blower fan in car for ventilation• Braille on push buttons• Door open and door close buttons in car operating panel.• Door closing retries• Door nudging• Emergency light• Full load by-pass• Infra–red screen for car door• Intercom Provision with Instrument• Motor overheat protection.•Overload function with audio-visuals indication in car operating panel.• Phase failure and phase reversal protection.• Automatic rescue device in case of power failure.• Attendant control Car arrival chime on car top/voice synthesizer.• LCD dot matrix scrolling display in car operating panel.• LCD matrix scrolling display in landing operating panel on all floors.• Fireman control.• Fireman emergency returnThe detailed additional specifications for passenger lift are provided in the tender document.The Job also includes The Site Clearence , Repairs and Minor adjustments if required and Necessary Earthing Including Excavation , Refilling Accessories, Masonary Enclosure with cover plate having Locking Arrangement, Electrode/Plate, Wire of the Lift Equipments as per the OEM Recommendations Complete JobThe Job also includes the Defect Liability Period (DLP) for a period of two (02) Years for all lifts. |
| 2 | Finishing walls with water proofing cement paint of approved brand and manufacture &of rqd shade to give an even shade New work (2or more coats) applied @3.84kg /10sqm |
| 3 | White washing with lime to give an even shade on New Work (three or more coats) |
| 4 | Providing and fixing of the suitable lifting/hoisting beam(ISMB-300) at the overhead of lift shaft. The job includes providing and fixing of base plates with the shaft walls by means of anchor fasteners and welding of the beam with the base plates after proper alignment. (to be paid as per actual). Job includes applying a priming coat of approved steel primer. |
| 5 | Supply, installation and wiring of IP65-rated LED bulkhead lights in the lift shaft, including secure mounting, conduit wiring, connection, testing and commissioning as per approved specifications.(to be paid as per actual) |
| 6 | Providing and fixing of ladder fabricated out of structural steel of requisite sections in pit for maintenance, inspection, emergency access to lift shaft etc. (to be paid as per actual). Job includes applying a priming coat of approved steel primer if required. |
| 7 | Electrical Works:Supply, installation, testing & commissioning of 3-Phase-75 KVA servo-stabilizers including all allied electrical accessories. The stabilizer should have following specifications:a) Capacity:75 KVA, 3-phase unbalanced typeb) Input: (90-265) V AC P-N; (156 - 460) V AC P-Pc) Output: 415 V ± 1% - phase to phased) Supply: 3 phase, 4 wires, 50Hze) Operation: Automaticf) Duty cycle: Continuousg) Transformer windings: Copper wound on CRGO laminations as per IS specificationsh) Cooling: Oil cooledi) Efficiency: Better than 98% at full loadj) Overload capacity: 15% for continuous 4 hoursk) Waveform distortions: Nill) High speed voltage correction: up to 8V to 20V per second m) Protections: Under voltage, Over voltage and Overload with time delay.n) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, Stabilizer by-pass arrangement.The Job also includes providing of 01 No. Earthing as required complete in all aspects.The scope of work also includes RCC/Concrete Foundation (1;2;4) Mix along with Canopy 50mm ISI approved Square Sections and 35 mm Equal Angles or whatever is required on site. for rain and snow protection to the satisfication of the Engineer in Charge.Complete Job |
| 8 | Design, fabrication, supply, installation, testing, and commissioning of Outdoor Type Control Panel, duly manufactured from CPRI-approved manufacturer, made out of 12 SWG CRCA (IS 375) mild steel sheet, 2 mm thick, powder-coated with RAL 7035, floor/wall-mounted, vermin and dust-proof, Provided With a Sloped top design suitable for outdoor installation. The panel shall be provided with suitable size angle iron legs to be grouted in the ground, lockable hinged doors, and painted finish. The enclosure shall have provisions for fixing switchgears, Aluminium bus bars of various ratings (considering derating factor), and other allied accessories as required. The panel shall be fabricated as per approved design; size may vary according to site requirements (not less than 8 CFT). The panel shall fully comply with IS 8623 / IEC 61439 standards for low voltage switchgear assemblies.a) 250A 4P 36KA MCCB 01 No. (Servo Incomer)b) 300A AL Busbar Chamber 01 Set.c) Digital Ammeter and Voltmeters.d) Colour coded internal wiring for indicating lamp etc., complete in all respects.Outgoing feeders:a) 63A TPN MCB 05 No. with push button and ON/OFF indicating lights – 05 Nos. The Job also includes earthing of the Panel as per OEM standards as well. |
| 9 | Supply, Laying, Connecting and Commissioning of 120sq mm 4 core XLPE/ PVC Insulated and Steel armored 1.1 KV grade Aluminium LT cable from Sub Station to Panel Near Servo incl. cost of required . thimbles duly crimped. (Over head/ under ground). |
| 10 | Supply, Laying, Connecting and Commissioning of 10 sq mm 4 core XLPE/ PVC Insulated and Steel armored 1.1 KV grade Aluminiumr LT cable incl. cost of required . thimbles duly crimped. (Over head/ under ground). |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required.120 mm dia (OD-120mm & ID-103 mm nominal) for 120 sq mm cable |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) for 10 sq mm cable |
| 13 | Comprehensive Annual Maintenance Contract (CAMC)Comprehensive Annual Maintenance Contract (CAMC) of above lift which includes routine, preventive & breakdown maintenance for period of ONE YEAR including repair/replacement of worn-out items with minimum downtime and warranty & guarantee of repaired/replaced items after completion of Two-year DLP period. |
| 14 | CIVIL PART\\"Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 15 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 16 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 17 | Providing and fixing, in position concealed G.I section for wall panelling using board of required thickness fixed on the ‘W’ profile (0.55mm thick) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610mm C/C with fully threaded self-tapping dry w all screws. Board is fixed to the ‘W’ profile with 25mm countersunk ribbed head screws @ 200mm C/C, all complete as per the drawing and directions of engineer- in-charge. The joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Multipurpose cement board reinforced with suitable fibre cement screw. 8 mm thick cement fibre board as per IS : 14862 |
| 18 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 19 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour or shade (Area of slab upto 0.5 sqm). 18 mm |
| 20 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes |
| 22 | Engagement of Skilled and unskilled labour for re-alignment / relocation of MS railing, purlins, trusses etc including cost of labour, machine and welding complete job.a) Blacksmith/ Skilled labour |
| 23 | b) Unskilled labour |
| 24 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm |
| 25 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:2:4 or richer mix (i/c equivalent design mix) |
| 26 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 27 | Providing and laying Stone soling hand packed incl ramming, watering etc complete job |
| 28 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 29 | Providing and laying in position Reinforced cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations: footings, bases of columns etc. for mass concrete. |
| 32 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2mm Thick) |
| 33 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 34 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats) |
| 35 | Providing, drilling, cleaning of hole and fixing M20 chemical anchor bolts using HAS-U threaded rod with injectable epoxy adhesive system (HIT-RE 500 V3 of Hilti or equivalent approved make). including hole drilling. wire brushing, air cleaning, injection of chemical adhesive. placement of threaded rod, curing. tightening. alignment, embedment depth 220 mm, and all labour, materials, tools, and equipment complete. |
| 36 | DG SETSupplying, Installation, Testing & Commissioning of 82.5 KVA DG set ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as mentioned, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications and consisting of the followings:Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electricstart of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, comprising to all relevant IS/BS standards in vogue as per CPWD specifications Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication(vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel LevelAlternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613suitable for tropical conditions and with class- H insulation.Base Frame and FUEL TANK: : As per CPWD specificationsExhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be waterproof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position MCCB with electronic release forO/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( L N & L_L), kW, kVA (Phase & Total), Frequency, KWH,PF.6. LED Indicating lamps for load on mains and load onset7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9.Main supply failure monitor10.Supply failure timer11.Restoration timer12. Impulse counter with locking and reset facility.13.ON/OFF/Control circuit switch with indicator14.Audio/Video annunciation for (i)High water temperature (ii)Low lubricating oil pressure (iii)Engine over speed (iv)Engine fails to start (v)Full load/maximum load warning15.Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories16. Maintenance notification based on Engine Run Hour & due dateThis Job aslo includes syncronisation of control panel with DG-Set |
| 37 | Earthing of DG Sets: -Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangements and watering pipe of 2.7 Meter long etc. with charcoal/coke and salt as reqd. The job also includes supplying and laying 4 mm dia copper wire in 15 mm dia GI Pipe from copper earth plate including connection/ termination with copper thimble etc. as required. (04 No’s per DG set).Complete Job.Earth resistance to be maintained below 1 Ω and tested using clamp-type earth tester after installation. |
| 38 | RCC Foundation and Canopy: P/L of RCC foundation block of minimum 2 ft height and Canopy to withstand wind and snow load as per the manufacturer’s recommendations in 1:2:4 (1cement: 2 sand :4 stone aggregate) including cost of Steel Truss works (3 inch square section and 2 inch angles or whatever required on site), Centering, shuttering, earthwork work etc. complete Job to the Satisfaction of Engineer in In charge. The Size of the Foundation shall be suitable to fit the DG Set. |
| 39 | Supply, Laying, Connecting and Commissioning of 70 sq mm 4 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable from 82.5 KVA DG set to AMF Panel near mains panel incl. cost of required al. thimbles duly crimped. (Over head/ under ground). |
| 40 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) for 70 sq mm cable Please Enable Macros to View BoQ information |