| 1 | S&F in repair rotary type hermetically sealed compressor suitable for 1.5 TR split AC unit, ISI marked, including installation, testing and commissioning complete as per manufacturer’s specification complete all as specified and as directed. |
| 2 | S&F in repair copper condenser coil for 1.5 TR split AC, heavy gauge, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. |
| 3 | S&F in repair evaporator coil with anti-corrosive coating for 1.5 TR split AC, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. |
| 4 | Supply and laying in repair soft drawn copper refrigerant pipe 5/8\\" and 1/4\\" pair with 19mm nitrile rubber insulation, ISI marked, including supports and installation, complete all as specified and as directed by Engr-in-Charge. |
| 5 | S&F in repair 25mm PVC drain pipe with clamps and accessories, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. |
| 6 | S&F in repair 19mm thick nitrile rubber insulation for suction and liquid line, ISI marked, including installation, complete all as specified and as directed by Engr-in-Charge. |
| 7 | S&F in repair 3 core, 2.5 sqmm copper flexible cable, ISI marked, including wiring from indoor to outdoor unit, complete all as specified and as directed by Engr-in-Charge. |
| 8 | S&F in repair 40 mfd capacitor for AC compressor, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply, install and testing in repair digital programmable thermostat for split AC, ISI marked, complete all as specified and as directed by Engr-in-Charge. |
| 10 | S&F in repair PCB control board for 1.5 TR split AC, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. |
| 11 | S&F in repair condenser fan motor suitable for 1.5 TR split type AC, including installation and testing, complete all as specified and as directed by Engr-in-Charge. |
| 12 | S&F in repair of 4 KVA voltage stabilizer with time delay, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. |
| 13 | S&F in repair MS powder coated wall mounting brackets in type of walls/ surface for fixing of outdoor unit, ISI marked, including installation, complete all as specified and as directed. |
| 14 | Supply, fabrication, installation, testing and commissioning in repair weather proof canopy for split AC, outdoor unit suitable for upto 2.0 TR, made of CRCA sheet (minimum 2.0 mm thick), duly powder coated/ enamel painted for corrosion resistance, suitable size to fully cover outdoor unit, including MS angle frame size not less than 25mm x 25mm x 5mm, nuts, bolts, clamps, anchors, cutting, welding, hoisting, fixing on wall/ floor, complete in all respects as per direction of Engineer-in-Charge. |
| 15 | S&F in repair condensate water storage tank for Split AC, made of PVC or as sample approved, capacity 50 litres complete with inlet from AC drain line, outlet valve, cover/ lid, supporting stand/ brackets or fixing on type of wall/ surface including necessary fittings, connections and making good, complete in all respects as per direction of Engineer-in-Charge. |
| 16 | S&F in repair brass flare nut for split AC outdoor unit, suitable for 1/4\\" & 3/8\\" copper refrigerant piping, compatable with R-32/ R-410 A, complete in all respects as per direction of Engineer-in-Charge. |
| 17 | Supply, installation, testing and commissioning in repair split type air conditioner indoor unit suitable to 2.0 TR capacity for cooling of residential/ commercial spaces complete as per specifications and technical requirements:- (a) Type : Wall mounted split AC – Indoor unit with suitable brackets, cooling medium : R-32/ R-410A (eco-friendly refrigerant), power supply : 230V ± 10%, 1 phase, 50 Hz AC, Noise Level : ≤ 40 dB(A) at normal operation, Air Filters : washable/ anti-bacterial/ dust filter, Louvers : Auto swing (four way), Control : LCD/ wireless remote control, Indoor Coil : Copper tube with aluminium fins, Drain System : PVC drain pipe with proper slope and scope includes : Indoor unit with factory fitted blower, cooling coil and filters mounting on wall including necessary clamps and fasteners electrical inter connection between indoor and outdoor unit condensate drain piping up to nearest drain point testing and commissioning complete in all respects as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 18 | Supply, installation, testing and commissioning in repair split type air conditioner indoor unit suitable to 2.0 TR capacity for cooling of residential/ commercial spaces complete as per specifications and technical requirements:- (a) Type : Wall mounted split AC – Indoor unit with suitable brackets, cooling medium : R-32/ R-410A (eco-friendly refrigerant), power supply : 230V ± 10%, 1 phase, 50 Hz AC, Noise Level : ≤ 40 dB(A) at normal operation, Air Filters : washable/ anti-bacterial/ dust filter, Louvers : Auto swing (four way), Control : LCD/ wireless remote control, Indoor Coil : Copper tube with aluminium fins, Drain System : PVC drain pipe with proper slope and scope includes : Indoor unit with factory fitted blower, cooling coil and filters mounting on wall including necessary clamps and fasteners electrical inter connection between indoor and outdoor unit condensate drain piping up to nearest drain point testing and commissioning complete in all respects as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |