| 1 | SITC of Decorative Ornamental pole with Double arm bracket with or without Post Top Arm as required by department . Total height of the pole shall be 9000 mm nominal above the ground.The pole is made out of combination of plain mild steel tube with cast iron pedestal in three steps. Part 1 - High-quality MS comprising a bottom section of 139.7 mm dia × 3.6 mm thick × 3000 mm long, Part 2 - Middle section of 114.3 mm dia × 3.6 mm thick × 3000 mm long, Part 3 - Top section and arm of 89 mm dia × 3.6 mm thick × 3000 mm long. Base Plate - 400 × 400 × 16 mm thick base plate. CI Casting Ornamental Base min. length 1000mm, CI part ring - 5 nos.& other aluminium emblishments as per drawing. The Pole section shall be welded by certified welders using high and MIG welding process. A built in lockable service window is provided to accomodate a 6 amp SP MCB and 32 amp heavy duty connector for mains LILO connections in the bottom part of the pole. The decorative pole and double arm bracket shall be machines and polished properly to give it a smooth surface. The decorative pole and double arm bracket is coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethene base paintfor long life complete in all respect. pole will be delivered including required J bolts. A Logo of KDA or any sign given by department is to be embossed on pole by manufacturer .Makes :- Klite, Philips, Bajaj, Homedec , Neri, orient etc and Make is to be approved by department incharge. Quality test report from NABL approved labs / in house NABL approved labs including TPI reports will be submitted by Contractor. |
| 2 | SITC of Decorative Ornamental pole with Double arm bracket at two different levels(or same level as required) as per attached drawing . Total height of the pole with Double arm Bracket shall be 8000 mm nominal above the ground. The pole is made out of combination of grooved and plain mild steel tube with cast iron pedestal in three steps .Part1- MS Ribbed pipe bottom part pole Dia:- min. 130 mm, Length:-3000 mm Thickness - min.3 mm. Part 2- MS pipe middle part pole Dia:- min.89 mm, Length:-3000 mm Thickness - min.3 mm. Part 3- MS pipe top part pole Dia:- min. 114 mm, Length:-1000 mm Thickness - min.3 mm. Part 4- MS pipe top arm centre pipe pole Dia:- min. 76 mm, Length:-1000 mm Thickness - min.3 mm. Part 5 - Arm bend pipe Dia:- min. 42 mm, Length:-2000 mm *2 =4000 mm ,Thickness - min.2.8 mm. MS Base plate 400*400*16 mm . CI Casting Ornamental Base min. length 850 mm, CI Part ring -5 nos. & other aluminium emblishments as per drawing. The pole section shall be welded by certified welders using high and MIG welding process . A built in lockable service window is provided to accommodate a 6 amp SP MCB and 32 amp heavy duty connector for mains LILO connections in the bottom part of the pole . The Decorative Pole and Double arm bracket Shall be machined and Polished properly to give it a smooth Surface. The Decorative pole with Double arm bracket is coated with epoxy zinc phosphate primer and finished using envirnmentally stable polyurethene base paint for long life complete in all respect pole will be delivered including required J bolts. Make is to be approved by department incharge .Quality test report from NABL approved labs/ in house NABL approved labs including TPI reports will be submitted by contractor . |
| 3 | SITC of LED Decorative Heritage Luminaire 100W without decorative arm , BIS certified with an upper body of spun aluminum (Dia 564mm) in heritage look pattern and a protector, made of UV-resistant Injection Moulded Polycarbonate (PC) with IP66 water & dust ingress protection and IK09 impact protection. The heat sink is made up of high Pressure Die Cast aluminum. Offered with PC Lens and other options in optical distributions providing excellent photometry to optimally cater to all kinds of road, pathway, area illumination applications. Suitable for suspended mounting on decorative Pole arms. Offered with System Lumen Efficacy of 110lms/W at Correlated Color Temperature (CCT) of 3000K to 5700K as required, Color Rendering Index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, System Power 100W, rated voltage 240VAC, Power Factor ≥ 0.95, offered with BIS certified potted DALI/ 0-10V dimmable driver having Internal surge protection of 4kV (in both Common & Differential Modes) and an additional/external Surge Protection Device (SPD) of 10/10kV (in both Common & Differential Modes). The luminaire shall also be compatible with a LoRaWAN based streetlight controller (Non- NEMA) for communication and control compatibility with DCU for smart lighting applications. Makes :- Klite, Philips, Bajaj, Homedec , Neri, orient etc and Make is to be approved by department incharge. Quality test report from NABL approved labs / in house NABL approved labs including TPI reports will be submitted by Contractor. |
| 4 | SITC of LED Decorative Heritage Luminaire 50W without decorative arm, BIS certified with an upper body of spun aluminum (Dia 480mm) and a protector, made of injection moulded polycarbonate (PC) clear with IK 07 rating & IP66 protection. The heat sink is made up of high Pressure Die Cast aluminium. Offered with PC Lens and other options in optical distributions providing excellent photometry to optimally cater to all kinds of road, pathway, area illumination applications. Suitable for suspended mounting on decorative bracket. Offered with System Lumen Efficacy of 110 lms/W at Correlated Colour Temperature (CCT) of 3000 Kto 5700K as required , Colour Rendering Index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, System Power 60W, rated voltage 240VAC, Power Factor ≥ 0.95, offered with BIS certified potted driver having Internal surge protection of 4/4kV (in both Common & Differential Modes) and an additional/external Surge Protection Device (SPD) of 10/10kV (in both Common & Differential Modes). The luminaire shall also be connected with a LoRaWAN based streetlight controller (Non-NEMA) for communication and control compatibility with Tata DCU for smart lighting applications. Makes :- Klite, Philips, Bajaj, Homedec ,Neri , orient etc and Make is to be approved by department incharge. Quality test report from NABL approved labs / in house NABL approved labs including TPI reports will be submitted by Contractor. |
| 5 | Operation, Maintenance and Security of Decorative LED Light System With Fixtures and Perform Following Work.(i)Maintain power supply (underground and overhead) from kedl/jvvnl energy meter to auto on off pannel to feeder piller to Decorative pole to led light including line fault.(ii) Repair , Rectification, Replacement of defective component of the Existing Led light or entire led light if required so to run led light system(Material like driver, led light will be provided by existing civil contractor who completed the beautification work and has DLP of work.)(iii)Replacement of old led light with new led light if led found broken/damage/stolen. (iv)Replacement of damage or burnt cable/overhead line with new cable/overhead line from from kedl/jvvnl energy meter to auto on off pannel to feeder piller to decorative pole junction box in supervision of engineer. For this work payment shall be extra. (v)Repair of damage cable and overhead line from kedl/jvvnl energy meter to auto on off pannel to feeder piller to decorative pole. (vi)Replacement and repair of damage /burnt /stolen cable , wire or jumper from junction box to decorative light. (vii)Operation maintenance and security of auto on off pannel / CCMS pannel installed by contractor as well as existing old pannel . If any part of pannel found defective/burnt/ stolen/damage contractor have to replace it with new parts and run the led system properly. (viii) Round the clock Bike patrolling by security guard for security of entire decorative light system maintaining by contractor.( 972 led* 36 month =34992 ) |
| 6 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 7 | 4 core*10 sqmm |
| 8 | 3.5 core*25 sqm |
| 9 | 3.5 core*70 sqmm |
| 10 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 11 | Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 12 | 125 mm X 200 mm X 122 mm |
| 13 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 14 | 50 mm |
| 15 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 16 | Single pole MCB (With B/C curve tripping Characteristics) |
| 17 | 6 A to 32 A rating |
| 18 | Four pole MCB (With B/C curve tripping Characteristics) 100 A rating |
| 19 | Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 20 | 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) |
| 21 | Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 22 | LT cross arm 600 mm long with clamp |
| 23 | Suspension clamp with eye hook & Pole clamp |
| 24 | Type A LT connector for Aerial bunched cable |
| 25 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 26 | 75mm x 90mm |
| 27 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 28 | 3 pole MCCB With Thermal Magnetic release |
| 29 | 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 30 | 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 31 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 32 | 3 pole Power contactors with following AC 3 Rating |
| 33 | 95 Amp |
| 34 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 35 | One day & week reserve (Analog type ) |
| 36 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 37 | Electrolytic grade Aluminium bus bar 6010 grade |
| 38 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 39 | 1 x 16.0 sq.mm |
| 40 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. |
| 41 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 42 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 43 | (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 44 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 45 | 100 mm dia. |
| 46 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 47 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 48 | 3.5 x 25.0 sq.mm |
| 49 | 3.5 x 70.0 sq.mm |
| 50 | 4 x 10.0 sq.mm |
| 51 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 52 | 3 core*6 sqmm |
| 53 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 54 | 10 SWG G.I. ( Hot Dipped ) Wire |
| 55 | Labour charges for Dismantling of following existing street light electric poles with street light fixtures, underground cable, MS box and other electric items of the pole coming along the alignment of the road and removal and re- rolling MS poles/PCC poles of different sizes as well as handing over the same to DISCOM/UIT/MC store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from concering authority, all complete works. |
| 56 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 57 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 58 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 59 | SITC of LoRaWAN based Individual decorative light Controller Non -Nema fixture on decorative pole having following specifications - LUX SENSOR, ON/OFF, SCHEDULING, METERING, DIMMING features Cloud based Smart Streetlight Application software, Dashboards and reports , License and subscription for 36 months ,Data Storage as required, Providing , Installation and Operation of Mobile App for customised information as per required by deptt. , Software modifications to accommodate up to 5 LED lamps for 1 lighting pole , Pole light driver should be dimmable , Including MRC (Monthly Recurring Charges) for Network, platform and data services for 36 months complete in all respect. Please Enable Macros to View BoQ information |