Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKEarthwork excavation in all kinds of soil as per drawing and technicalspecification including dressing and levelling the bed, sides and bottom and removing the excavated earth and depositing the same away from the work site within initial lead of 50m and initial lift of 1.5m, including cost, conveyance of all materials, all labour, T&P articles required for the work, including shoring, shuttering, propping and dewatering if required etc. complete in all respect as per direction of the Engineer-in-Charge. |
| 2 | GALLERY & COMMON FACILITY CENTER |
| 3 | COVER DRAIN |
| 4 | PLINTH PROTECTION |
| 5 | PAVER ROAD & PARKING |
| 6 | DRAINAGE WORK |
| 7 | BASKET BALL COURT |
| 8 | VOLLEY BALL COURT |
| 9 | LAWN TENNIS COURT |
| 10 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered. |
| 11 | GALLERY & COMMON FACILITY CENTER |
| 12 | Back filling with available excavated earth in foundation and trenches in layer not exceeding 20 cm in depth watering ramming with a lead upto 50m and lift upto 1.5m etc. incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 13 | GALLERY & COMMON FACILITY CENTER |
| 14 | DRAINAGE WORK |
| 15 | Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge. |
| 16 | GALLERY & COMMON FACILITY CENTER |
| 17 | DRAINAGE WORK |
| 18 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 19 | GALLERY & COMMON FACILITY CENTER |
| 20 | COVER DRAIN |
| 21 | PLINTH PROTECTION |
| 22 | PAVER ROAD & PARKING |
| 23 | DRAINAGE WORK |
| 24 | BASKET BALL COURT |
| 25 | VOLLEY BALL COURT |
| 26 | LAWN TENNIS COURT |
| 27 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. |
| 28 | PLINTH PROTECTION |
| 29 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
| 30 | GALLERY & COMMON FACILITY CENTER |
| 31 | COVER DRAIN |
| 32 | BASKET BALL COURT |
| 33 | VOLLEY BALL COURT |
| 34 | LAWN TENNIS COURT |
| 35 | Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect. |
| 36 | PLINTH PROTECTION |
| 37 | DRAINAGE WORK |
| 38 | R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. |
| 39 | COVER DRAIN - R.C.C. roof slab |
| 40 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 41 | GALLERY & COMMON FACILITY CENTER |
| 42 | GROUND FLOOR |
| 43 | Foundation & bases of column |
| 44 | DRAINAGE WORK |
| 45 | Foundation & bases of column |
| 46 | Plinth Beam |
| 47 | Columns |
| 48 | Roof Beam |
| 49 | Lintel |
| 50 | Chajja |
| 51 | R.C.C. staircase |
| 52 | R.C.C. floor and roof slab |
| 53 | FIRST FLOOR |
| 54 | Columns |
| 55 | Roof Beam |
| 56 | Lintel |
| 57 | Chajja |
| 58 | R.C.C. floor and roof slabs |
| 59 | R.C.C. staircase |
| 60 | DRAINAGE WORK |
| 61 | RCC Wall |
| 62 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 63 | GROUND FLOOR |
| 64 | GALLERY & COMMON FACILITY CENTER |
| 65 | COVER DRAIN |
| 66 | DRAINAGE WORK |
| 67 | FIRST FLOOR |
| 68 | GALLERY & COMMON FACILITY CENTER |
| 69 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 70 | GALLERY & COMMON FACILITY CENTER |
| 71 | COVER DRAIN |
| 72 | PLINTH PROTECTION |
| 73 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 74 | GROUND FLOOR |
| 75 | GALLERY & COMMON FACILITY CENTER |
| 76 | BASKET BALL COURT |
| 77 | VOLLEY BALL COURT |
| 78 | LAWN TENNIS COURT |
| 79 | FIRST FLOOR |
| 80 | GALLERY & COMMON FACILITY CENTER |
| 81 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.GROUND FLOOR |
| 82 | GALLERY & COMMON FACILITY CENTER |
| 83 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (INSIDE WALL)GALLERY & COMMON FACILITY CENTER |
| 84 | GROUND FLOOR |
| 85 | FIRST FLOOR |
| 86 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 87 | GROUND FLOOR |
| 88 | GALLERY & COMMON FACILITY CENTER |
| 89 | DRAINAGE WORK |
| 90 | FIRST FLOOR |
| 91 | GALLERY & COMMON FACILITY CENTER |
| 92 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). outside brick walls after racking out the joints, including watering and curing, with costs covering conveyance, loading, unloading, royalties for all materials, labour, transportation and provision (T&P), sundries, and scaffolding required for the work, as well as providing grooves as directed by the Engineer in charge. (OUTSIDE WALL)GALLERY & COMMON FACILITY CENTER |
| 93 | GROUND FLOOR |
| 94 | FIRST FLOOR |
| 95 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 96 | COVER DRAIN |
| 97 | PLINTH PROTECTION |
| 98 | Providing neat cement punning over plastered/ concrete surface including watering and curing complete with cost, coveyance, loading and unloading, royalties of all materials and cost of all labour, T&P and scaffolding required for the work etc. as directed by the Engineer in charge. |
| 99 | COVER DRAIN |
| 100 | Supplying, fitting and fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.GROUND FLOOR |
| 101 | GALLERY & COMMON FACILITY CENTER |
| 102 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.GROUND FLOOR |
| 103 | GALLERY & COMMON FACILITY CENTER |
| 104 | Fixing granite stone of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.GROUND FLOOR |
| 105 | GALLERY & COMMON FACILITY CENTER |
| 106 | Providing Granite stone prepolished 10mm thick in dado of area above 0.10sqm & up to 0.4 sqm approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.GROUND FLOOR |
| 107 | GALLERY & COMMON FACILITY CENTER |
| 108 | Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge.GROUND FLOOR |
| 109 | GALLERY & COMMON FACILITY CENTER |
| 110 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.GROUND FLOOR |
| 111 | GALLERY & COMMON FACILITY CENTER |
| 112 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.GROUND FLOOR |
| 113 | GALLERY & COMMON FACILITY CENTER |
| 114 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 115 | GALLERY & COMMON FACILITY CENTER |
| 116 | GROUND FLOOR |
| 117 | FIRST FLOOR |
| 118 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Inside wall)(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 119 | GALLERY & COMMON FACILITY CENTER |
| 120 | GROUND FLOOR |
| 121 | FIRST FLOOR |
| 122 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 123 | GALLERY & COMMON FACILITY CENTER |
| 124 | GROUND FLOOR |
| 125 | FIRST FLOOR |
| 126 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 127 | GALLERY & COMMON FACILITY CENTER |
| 128 | GROUND FLOOR |
| 129 | FIRST FLOOR |
| 130 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Outside wall)(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 131 | GALLERY & COMMON FACILITY CENTER |
| 132 | GROUND FLOOR |
| 133 | FIRST FLOOR |
| 134 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge)GROUND FLOOR |
| 135 | GALLERY & COMMON FACILITY CENTER |
| 136 | Providing approved primer of one coat to the Iron work including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as directed by Engineer-In-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge)GROUND FLOOR |
| 137 | GALLERY & COMMON FACILITY CENTER |
| 138 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )GROUND FLOOR |
| 139 | GALLERY & COMMON FACILITY CENTER |
| 140 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.FIRST FLOOR |
| 141 | GALLERY & COMMON FACILITY CENTER |
| 142 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment). |
| 143 | GALLERY & COMMON FACILITY CENTER |
| 144 | Providing and fixing of UPVC sliding windows 2/3 track sliding-60 series/Top hung ventilator of any approved make ,duly manufactured using upvc reinforced profiles of 62mm x 60mm x 2.25mm for outer frame, 66mm x 38mm x 2.25mm for sliding shutter frames capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.2 mm prefabricated and welded through fusion welding & the window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with EPDM weathering seal including the cost of all materials,necessary locking arrangements ,fittings,cost of labour,T&P ,etc complete as per direction of Engineer-in-charge.GALLERY & COMMON FACILITY CENTER |
| 145 | GROUND FLOOR |
| 146 | FIRST FLOOR |
| 147 | Glass doorSupplying , fitting and fixing of openable UPVC doors with frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 148 | GALLERY & COMMON FACILITY CENTER |
| 149 | Providing and lying integram cement based water proffing traetment including preparertion of surface as required for treatment of roofs, balconies, terrace etc consisting of following operations: (a) Applying a slurry cot of neaat cement using 2.75kg/sqm of cement aadmixed with water proffing compound comforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using briken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortr 1:5 (1 cement : 5 coaarse sand) admixed with water proffing ompound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick laayer of cement mortr of mix 1:5 (1 cement 5 coarse saand) admixed with water proffing compound conforming to IS : 2645 and approved by Enginer-in-charge to required slope and treating similarly the adjoining wall up to 300 mm height including rounding of junctions of waall and slabs. (c) After two dys of proper curing applying a second coat of cement slurry using 2.75 kg/sqqm of cement admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 Coarse cement sand) admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge (approved jajpur court builibing) |
| 150 | FIRST FLOORGALLERY & COMMON FACILITY CENTER |
| 151 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdor floors such as footpath, courtyard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 152 | GALLERY & COMMON FACILITY CENTER |
| 153 | TENSILE FIBER STRUCTURE :-Design, Supply and Installation of tensile membrane fabric 1050GSM, both sides PVDF coat, with tensile strength 280/ 280 daN/5cm, tear strength 30/ 28 daN of serge Ferrari or equivalent as per the manufacturer's specification and 15-year manufacturer's warranty or equivalent. Flame Retardancy M2/NFP92-507, The membrane shall be cut and manufactured with a high-frequency PVC welding machine. The rate is inclusive of all fittings and fixtures. |
| 154 | Design, Supply, fabrication and erection of ms steel structures for tensile fabric. Including color, primer, pipe bending, materials shifting including all machinery, labor, tools and hydra. |
| 155 | INTERIOR FURNISHING WORKS :-Supply and Installation of false ceiling Aeroceil/ Armstrong/ Anutone equivalent 12 mm thick Tufbloc magnesium oxide HDFR boards of size 1200 x 2400 mm having Density-1000 kg/mt cube, with STC- 34 – 50, weight - 12 kg /sq mt, Fire Class - 1&P & Thermal Heat Resistance - 0.11792 W/mK Climate ( degree Centigrade , RH - 50,95 , Green VoC , RC% - Low & 30 Water resistant with wet expansion less than -0.02% from ambient to saturation, Moisture Movement - 0.02% from Anutone are to be fixed with Philips head screw is fixed by using concealed ceiling system. The concealed ceiling system shall include GI Wall channel(WC 25) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 22 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. |
| 156 | Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) having thickness 0.45 mm, length 3600 mm, knurled web 35mm, depth of 25 mm and equal flanges 9.5 mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers.Now the jointing & finishing of the same will be done by using Anutone jointing kit consist of powder mixed with water and apply the same with flat flap on the boards joints to finish the surface of the boards so as to look flush. Test certificate of the use products shall be submitted after procurement of materials including cost, conveyance, loading, unloading of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 157 | Supply and Installation of Aeroceil/ Anutone/ Armstrong/ equivalent 8 mm thick magnesium oxide square edge magnesia core ceiling tile of size 595 x 595 mm having density 1000 Kgs/ m3, weight 8 kg/m2 which is suspended by using 0.3 mm thick and 24 mm wide precoated metalAnutone T 24 grid system. The technical parameters are as follows :Core - Magnesia, Fire – Class 1 & P, Acoustics – STC 44 - 54 , climate - 50 , RH - 95, Termite resistance ,Green (RC %) – 30, Hygiene (VoC, Clean room) – Low, Class 3 , Thermal -0.12 W/mK. The T 24 Grid system of 600 x 600 mm module shall include wall angle (WA 24 W 30) with unequal flanges of size 14 & 20 mm wide, length 3000 mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300 mm centers. Then suspend the Main T 24(MT 24 W 36) having flange width 24 mm, height 32 mm and length 3600 mm from the soffit with help of soffit cleat and wire rod along with leveling spring clip at 1200 mm c/c. Cross 24(CT 24 W 12) with flange width 24 mm, height 32 mm and length 1200 mm is then interlocked into the precut slots in the Main T 24 at 600 mm centers in the direction perpendicular to the Main Anutone T 24. Finally Cross T 24 (CT 24 W 06) having flange width 24 mm, height 32 mm and length 600 mm are then interlocked into the precut slots in the 1200 mm Cross T 24 at 1200 mm centers and in direction parallel to the Main T 24. Anuton Magnesium oxide vinyl square edge of size 595 x 595 x 8 mm thick shall be placed into the grid size of 600 x 600 mm. Test certificate will be submitted after procurement of materials. |
| 158 | Supply and installation of Anutone/ Aeroceil Astral Serge Lance, Metal grille ceilings of size 25x100x3000x0.5mm thk, cellsize 100/150/200mm c/c, square edge, made up of Galvanised Mild steel, installed using Anutone Strut ceiling system. Anutone Strut ceiling system includes Anutone Strut Carrier, having 8mm circular perforations at 50 mm pitch, sectional thickness 1.2mm, length 3600mm, equal flanges of 21mm, hung from the soffit at 1200mm centers with Hanger rod and soffit cleat (Hangerrod and soffit cleat not by Anutone).C Hanger is fastened to Strut Carrier above at every 100/150/200mm.C Hanger is used as Connector Clip to Connect Strut Carrier and Serge Lance.Serge Lance is fastened to C Hanger at interval of 100|150|200mm or as per architectural drawing•Fire (Class) – A |
| 159 | Providing and fixing gypboard suspended false ceiling (single layers) in different levels, recesses, flat areas as per design with G.I. Framework using Gypsteel of perimeter channels, intermediate channels and ceiling sections) and 12.5 mm taped edge gypboard screw fixed to ceiling section as per design , complete with fixing and finishing of tapered and square edges of board with jointing compound paper tape and 2 coats suitable primer including all cost of materials , labour, overheads T & P etc., complete.and painting the entire ceiling area with plastic emulsion paint ( 2 & more coats ) to get an even shade as per the detail design and specification. measurement will be taken flat area of the ceiling for payment.no additional payment made for the different level/ drop. |
| 160 | SITE DEVELOPMENT-PAVER ROAD & PARKING :-Cleaning & grubbing road land including uprooting rank vegetation, grass, bushes, shurbes,sapling and trees girth upto 300mm ,removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness |
| 161 | Loosening and Compacting original ground supporting embarkment to facilitate placement of first layer of embarkment, scarified to a depth of 150mm ,mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embarkment construction & clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 162 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 163 | Providing & laying of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by Block making machine with proper compaction laid in required patteren etc.comple in all respect conforming to IRC SP- 63:2018 as per direction of Engineer-in-charge. |
| 164 | Providing & laying precast, precured cement concrete (M-25 grade) Kerb stone (400x300x150mm) with graded stonne aggregates & fixing in position & pattern as shown in drawing with cement mortar of (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required including cost of all materials, labour, lead, T&P etc. complete in all respect (excluding GST) as per specification and as directed by Engineer-in-charge. |
| 165 | Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 100mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge. |
| 166 | Grassing with Providing and laying Grassing with carpet grass(zoysia japonica) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed. In rows 5 cm. apart in either direction. |
| 167 | LAND SCAPING WORKGREENERY DEVELOPEMT THROUGH LAWNSupply of cow dung manure, well decomposed, garbage free including transportation & delivery at nursery per tractor load etc., all completed |
| 168 | Lifting & spreading of manure uniformly over the surface area as per landscape design/advice of the site in-charge & all completed. |
| 169 | Supply of broad leaf grass turf, disease free, glossy green etc. well grown, carpet formed 2' thickness about for an area of 15613 sqmtr. Including transportation & delivery at site as per instruction of in-charge at site at 1:5 ratio for dibbling etc., complete all respect. |
| 170 | Dibbling of grass in required spacing including rolling, 1st watering & maintenace of the lawn to make it free from weeds top dressing with fertilizer and pesticide and mixture of grass planting as per instruction of Officer in-charge at site & complete in all respect |
| 171 | PLANTATON OF ORNAMENTAL, SHRUBS, SPECIMEN & DECORATIVE PANTS |
| 172 | Colium potted plants in 10\\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 173 | Thuja 3'ht. Potted plants, well grown, decorative stage, healthy & disease free including transportation and delivery site. |
| 174 | Red Dracena potted plants in 10\\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 175 | Bougainvillea potted plants in 10\\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 176 | Dracena (Yellow Colour) potted plants in 10\\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 177 | Bougainvillea (Poly pack) plants in 10\\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 178 | SITE LEVELING :-Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification including cost of material, conveyance, royalty, taxes and other charges with labour and T&P charges for loading, unloading and stacking at site completer in all respect as per direction of Engineer/Architect in charge. |
| 179 | Considering 50% Granular material/ morrum |
| 180 | Considering 50% sandy material |
| 181 | Supply of good quality garden soil preferably red alluvial/ sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining adequate humus with a ph range from 6.5 to 7.5 should be free from any undesirable inorganic materials like wastage construction, roots and bushes of wild plants, polythene garbage etc. to be collected after duly screened including cost, conveyance, royalty, taxes and other charges with labour and T&P charges for loading, unloading and stacking at site in separate heaps of (1.5X1.5X0.5) cum or its multiplies taken into 1(one) cum for measurement and payment purpose and to be uniformly spreaded over an area of 6000 sq.mtr with average thickness of 6 cm and completed in all respects. |
| 182 | Lifting and spreading of good garden soil uniformly over the surface area as per landscape design/ advice of the site in-charge & all completed |
| 183 | SPORTS FACILITIES :CONSTRUCTION OF BASKETBALL, VOLLEYBALL & LAWN TENNIS COURT-Cleaning & grubbing road land including uprooting rank vegetation, grass, bushes, shurbes,sapling and trees girth upto 300mm ,removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness |
| 184 | BASKET BALL COURT |
| 185 | VOLLEY BALL COURT |
| 186 | LAWN TENNIS COURT |
| 187 | Providing and fixing of MS welded mesh of size 25x25 mm of dia 2 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 188 | BASKET BALL COURT |
| 189 | VOLLEY BALL COURT |
| 190 | LAWN TENNIS COURT |
| 191 | RCC M20 grade concrete using 20mm down well graded CBHG chips including all cost of labour, T&P etc. complete. |
| 192 | BASKET BALL COURT |
| 193 | VOLLEY BALL COURT |
| 194 | LAWN TENNIS COURT |
| 195 | Providing & fixing of goal post Supplying and laying of 3 Layer Synthetic Surface which includes one layer of resurfacer, a layer of filler colour coat and a layer of top colour coat followed by International Standard White line marking as per FIFA norms and terms including cost, conveyance, loading, unloading & fixing of materials, cost of labour, T&P etc complete.as per the direction of the architect in charge |
| 196 | BASKET BALL COURT |
| 197 | VOLLEY BALL COURT |
| 198 | LAWN TENNIS COURT |
| 199 | Supplying and laying of 3 Layer Synthetic Surface which includes one layer of resurfacer, a layer of filler colour coat and a layer of top colour coat followed by International Standard White line marking as per FIBA norms and terms including cost, conveyance, loading, unloading & fixing of materials, cost of labour, T&P etc complete.as per the direction of the architect in charge |
| 200 | BASKET BALL COURT |
| 201 | VOLLEY BALL COURT |
| 202 | LAWN TENNIS COURT |
| 203 | SYNTHETIC TRACK SUB BASE WORK :-Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : |
| 204 | All kinds of soil |
| 205 | Earth work in excavation by mechanical means (Hydaulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for all lift and lead, including getting out the excavated soil and disposal of surplus excavated soils as directed, within all lead and lift. |
| 206 | All kinds of soil. |
| 207 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming , watering, etc. and disposing of surplus excavated soil as directed , within all lead and lift. |
| 208 | Pipes, cables etc. exceeding 80mm dia. but not exceeding 450 mm dia |
| 209 | CONCRETE WORK |
| 210 | Providing and laying in position cement concrete of specified grade including the cost of centring and shuttering - All work upto plinth level |
| 211 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 212 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 213 | Centering and Shuttering including sturting proping and removal of formwork for |
| 214 | Foundations, footings, bases for columns |
| 215 | Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc. |
| 216 | BRICK WORK |
| 217 | Maonry work with concrete /cement block or latrite stone work in foundation and plinth in : |
| 218 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 219 | FINISHING |
| 220 | 12 mm cement plaster of mix : |
| 221 | 1:4 (1 cement : 4 coarse sand) |
| 222 | Neat cement punning |
| 223 | ROAD WORK |
| 224 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres |
| 225 | Supplying and stacking at site : Good Earth |
| 226 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications of World Athletics and directions of Engineer-in-Charge. |
| 227 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 228 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications of World Athletics and directions of Engineer-in-Charge. |
| 229 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as perspecifications : |
| 230 | On W.M.M. @ 0.75 kg./sqm. |
| 231 | On bituminious surface @ 0.5 Kg/sqm |
| 232 | Providing and laying Bituminous Macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications toachieve the desired compaction and density, complete as per specificatons of World Athletics and directions of Engineer-in-Charge.(a) 50mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 233 | Providing and laying Bituminous concrete using crushed stone aggregates of specified grading premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification of World Athletics complete and as per directions of Engineer-in-Charge. |
| 234 | 30 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of100-120 TPH capacity |
| 235 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid In the required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 236 | NATURAL GRASS - FOOTBALL FIELD WORK |
| 237 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness |
| 238 | Earthwork in excavation up to 1.50mtr depth of foundation trenches for columns, basement, tiebeams, walls and steps in All Kinds of soil with initial leads and lifts including dressing and levelling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. Complete as per the drawing, design including cost of all labour,T&Petc.as required for the work complete as directed by the Engineer-in-charge. |
| 239 | Supplying and filling of sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. |
| 240 | Fine Dresing and Compaction (as per contour/level) using manually or machinary in all respect as per driection of EIC. |
| 241 | SUBGRADE: Preparation and consolidation of subgrade with power road roller of 8 to12 tonne capacity after excavating earth to an average of 22.5cm depth,dressing to camber andconsolidating with road roller including making good the undulations etc.andre-rolling the subgrade and disposal of surplus earth with lead upto 1 kms - finished item of work. |
| 242 | Supplying and stacking of good earth at site including royalty and carriage upto 5km complete(earth measured instacks will be reduced by 20% for payment). |
| 243 | Trench Cutting with supply of Machinary and manpower as per design with disposal of excavated earth from site with intial lead and lift complete the work as per direction of EIC. |
| 244 | Supply and Laying of 150 gsm Geotextile in the trench ( Make : ) with supply of labours, required tools, tackles including loading, unloading, transportation,etc. complete the work as per direction of EIC. |
| 245 | Supply and Laying of 160mm Pvc( Make : Astral/Supreme ) pipe with 6kg/cm2 including loading, unloading, transportation, fittings, cutting, fixing complete the work as per direction of EIC. |
| 246 | Supply and Laying of 100mm perforated Pvc( Make : Supreme/Astral ) pipe with 6kg/cm2 including loading, unloading, transportation, fittings, cutting, fixing complete the work as per direction of EIC. |
| 247 | Installation, jointing and fixing of Perforated Pipe 4\\" and 6'' with supply of materials and labours in all respect as per direction of EIC. |
| 248 | Supply and Laying of 10 mm aggregate in the trench and outfield with supply of Machine,labour, tools, tackles with proper level as per drawing complete the work as per instruction of EIC. |
| 249 | Supply and laying of Coarse sand over the aggregate of cricket pitch, bowling runup and Outfield with supply of Machine, labour, tools, tackles with proper level as per drawing complete the work as per instruction of EIC. |
| 250 | Supply and applying of of Organic Matter 100kg/100sqm(Neem Cake/ meliorate) in all respect as per direction of EIC. |
| 251 | Spreading and Mixing of OM on the top layer of Ground in all respect as per direction of EIC. |
| 252 | Supply and Applying of Basal Fertilization & Starter fertilizer in all respect as per direction of EIC. |
| 253 | Supply and sodding of washed treated bermuda sports tifway 419 bermuda grass stolens in all respect as per direction of EIC. |
| 254 | Development of Football field including mixing supplied sand tilling, De-weeding, sprigging/ seeding with improved barmunda variety suitable for local climatic condition in all respect as per direction of EIC. |
| 255 | Supply and laying RCC drain cover of size 600 x 600 x 60 mm with 8mm rods @ 100mmc/c over the walls of drain at proper level for ease flow of water |
| 256 | Supply and laying RCC drain cover of size 600 x 300 x 60 mm with 8mm rods @ 100mmc/c over the walls of drain at proper level for ease flow of water |
| 257 | Providing & Laying minimum 15 cm thick cement concrete slab over the existing sub base with a nominal mix of 1:1.5:3 (1 cement: 1.5 coarse sand:3 Graded stone aggregate 20 mm nominal size) forfixing throwing circles for Discus/Hammer /Shot-put in required diameter/size including cost of cutting the base and sub-base wherever necessary cost of fixing the required throwing circle rings for Discus/Hammer/Shot-put with necessary fixing arrangements as per direction of Engineer-in-Charge. The finished surface of concrete base slab shall have required non skid / non slippery finish and gradient as per requirements / specifications laid down by IAAF and as per directions of Engineer-in-Charge (the cost of throwing circle rings is not included in this item and shall be paid as part of competition equipment |
| 258 | Providing and fixing at or near ground level Precast cement concrete Kerb stones (300x300x150mm) of M-25grade of of specified size including setting in position in Kerbs edging etc. to the required line level and jointed with cement mortar 1:3 (1 cement : 3 coarse sand) making joints with or without grooves all complete as per direction of Engineer-in-charge. |
| 259 | Providing and fixing security chain link fencing around hockey ground 2.00 meter high vertical post made with MS square hollow section 72x72x4.8mm vertical post & Horizantal pipe of size 50x50x3.6mm MS square hollow section on fixing with chainlink fencing mesh size 2''x2'' of 10 gauge hot dip galvanized chian link fixed with spilt line/wire for tighting with MS flat 12x5mm. including fixing in position in concrete complete in all respect to the entire satisfaction of engineer-in-charge including carriage of materials within all leads and lifts and other incidantal charges. |
| 260 | Irrigation system |
| 261 | Supply and installation of irrigation system including 25mm upvc pipe, 40mm, 63mm and 75 mm with QC valave, Air release valve, isolation valve, irrigation controler, Filter, 640 series sprinkler, Swing joint, pvc fittings, Electrical wire,etc commissioning of the materials in all respect as per direction of EIC. |
| 262 | uPVC PIPE IS:4985 - Superme/Finolex Make |
| 263 | 75 MM 10kg/Cm2 PVC pipe |
| 264 | 63 MM 10kg/Cm2 PVC pipe |
| 265 | 40 MM 10kg/Cm2 PVC pipe |
| 266 | POP UP SPRINKLER SYSTEM : |
| 267 | TORO (U.S.A.) T7 Series Sports Sprinkler |
| 268 | 1'' Size Swing joint with four Elbow (Imported) |
| 269 | 75mm x 1'' Size Service Saddle (Imported) |
| 270 | 63mm x 1'' Size Service Saddle (Imported) |
| 271 | 40mm x 1'' Size Service Saddle (Imported) |
| 272 | 2'' Size Lateral Line PVC Ball Valve PN16 (Plasson make) |
| 273 | 2\\" Size Air Release Valve (Harit Make) |
| 274 | 1\\" Size Brass QCV (Harit Make) |
| 275 | 1\\" Size QCV Key (Harit Make) |
| 276 | 1\\" Brass Swivel Elbow (Harit Make) |
| 277 | 12'' Size Rectangular Plastic Valve Box- TORO(USA) |
| 278 | 10'' Size Round Valve Box -TORO(USA) |
| 279 | 6'' Size Round Valve Box -TORO(USA) |
| 280 | PUMPING SYSTEM : |
| 281 | Pump Set suitable to deliver 5.8 LPS with 58 Mtr.Head Monobloc Pump, Pressure Gauge, NRV, Ball Valve , Suction & delivery header pipe & fittings etc. |
| 282 | Control panel having MCB, Indicating Lamps Single Phasing Preventer, Star-delta Starting etc |
| 283 | 4 Sq. mm 3 core Power Cable for pump |
| 284 | Water Level for Automation |
| 285 | 2 HP Pump with Starter & fittings for Hydrant operation |
| 286 | 3'' Size Disc Filter with Fitting (Amiad make -Imported) |
| 287 | AUTOMATION ITEMS:- |
| 288 | 16 Station Irrigation Controller with Rain sensor + Stablizer TORO(USA) |
| 289 | 2\\" Size Solenoid Valves - Irritrol/Toro(USA) Make |
| 290 | 14 AWG White Direct Burial Wire (Macrotherm Make) |
| 291 | 16 AWG Red Direct Burial Wire (Macrotherm Make) |
| 292 | DBR/Y Splice Kit tape etc 3M USA |
| 293 | Heavy Duty PVC Fittings,saddles & Accessories, |
| 294 | Installation,Testing & Commissioning, Charges |
| 295 | Trenching & Back filling 1.5 feet deep |
| 296 | Providing and laying Synthetic REGUPOL 4.0 AG CHAMPION Athletics Track including WA Standard markings on the surface all complete as per requirements /specifications laid down by WA class -II certification and as per direction of the Engineer-in-charge. |
| 297 | (i) Normal Stress Areas with a minimum thickness of 15mm of finished track surface |
| 298 | (ii) High Stress Areas with a minimum thickness of 20 mm of finished Track Surface. |
| 299 | (iii) High Stress Areas with a minimum thickness of 25 mm of finished Track Surface. |
| 300 | Providing and applying UV Protective PU spray coat of WA approved Product Manufacture for required colour over top layer as per direction of engineer-in charge. |
| 301 | Construction of jumping pits filling with sand all complete as per drawing and as directed by Engineer-in-Charge. |
| 302 | Construction of Steeple chase water jump pit inside North D portion as per ''WA specification'' and complete as per direction of Engineer-in-Charge. |
| 303 | Supplying of track field equipments: |
| 304 | (a) Polevault box with cover |
| 305 | (b) Take of board system for Long jump/triple jump |
| 306 | (c) Hammer cum Discuss throwing circle with cage, net and poles. |
| 307 | (d) Shot put rings with toe board |
| 308 | (e) Discuss throwing circle with cage, net and poles. |
| 309 | (f) Aluminium Kerbing 400m standard track. |
| 310 | (g) Waterjump hurdle for steeple chase pit |
| 311 | (h) Convertion circle for Discuss cum hammer |
| 312 | (i) Football Goal post - FIFA approved design. |
| 313 | FOUNDATION FOR HIGH MAST LIGHT |
| 314 | Earthwork excavation in all kinds of soil as per drawing and technical specification including dressing and levelling the bed, sides and bottom and removing the excavated earth and depositing the same away from the work site within initial lead of 50m and initial lift of 1.5m, including cost, conveyance of all materials, all labour, T&P articles required for the work, including shoring, shuttering, propping and dewatering if required etc. complete in all respect as per direction of the Engineer-in-Charge. |
| 315 | Extra lift or 1.5m or part there of over the initial lift of 1.5m in all kinds of embankments and road works and ordinary earth work in general. |
| 316 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 317 | Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge. |
| 318 | Supplying and filling in foundation trenches and plinth with sand, well watered and rammed in layers not exceeding 23cm in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and , materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-Charge. |
| 319 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment). |
| 320 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (1 1/2\\") 0 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading,cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 321 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 322 | Foundation & bases of column |
| 323 | Columns |
| 324 | Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel welding or jointing if necessary, bending, binding, tying the grills as required for RCC works, and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost). |
| 325 | Construction of RCC storage sump well (UGT) of 75000 litres capacity complete including necessory excavtion, RCC work and accessories all complete as per drawing and as per the direction of engineer-in-charge. |
| 326 | Supply and installation of fully computerized, automatic and single key operation pop-up spinkler system specifically dsigned for football field including all fittings and accessories including earth work in excavation and re-filling (earth work includes 450mm of soil cover over the pipe and width of 300) HDPE pipe dia 150/110mm class pe 100 graede12.5g/cm2. ''including carriage of materials within all leads and lifts and other incidental charges. |
| 327 | Construction of pump house with brick mosonry ,RCC roof slab including necessory doors and window etc., all complete as per drawing and as per the direction of engineer -in charge. |
| 328 | Supplaying and instllation of 50H.P coupled pumping set with electronic controller etc.or equivalent ,making connections suitable for T W/D.C.B/ open well.the job includes screwing and welding of flanges on GI B-class riser pipes, installation of complete fittings and accessories with riser pipes,jointing of electrical cable and other connections .layout of the same along with details of product is to be got approved by the engineer-in-charge. |
| 329 | E.I. WORK(COMMON FACILITY CENTER & SECURITY GATE)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. |
| 330 | Group A |
| 331 | Group B |
| 332 | Group C |
| 333 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 334 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 335 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 336 | Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge. |
| 337 | Supplying and drawing TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in existing surface / recessed steel / PVC conduit as required as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. |
| 338 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 339 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 340 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 341 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 342 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 343 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 344 | 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 345 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 346 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,DP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 347 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 348 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 349 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year |
| 350 | Fittings & Fixtures |
| 351 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 352 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 353 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 354 | supply ,Installation and testing of 15W LED BULK HEAD WALL MOUNTED light with pressure die cast Aluminium housing and high transmitive PMMA diffuser IP 65 (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2years. |
| 355 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 356 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 357 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( fan Regulator compatible) |
| 358 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 359 | MAIN FEEDER PANEL S/I/T&Commissioning of CPRI tested LT outdoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 80X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 65kA 3P+N type 1+2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomers.Mandatory provision of cable alley is to be given.Incomer:1 800A 4P MCCB(36 KA) with LSIG microprocessor based, Ics=100%Icu Bus bar: 4 nos.900A Aluminum Busbar duly sleeved 1 no. 630A 4way MOTORISED CHANGEOVER SWITCH Outgoing: 4 Nos 250 A 4P MCCB 25 ka with LSIG microprocessor based, Ics=100%Icu , 2 no.400A 4P MCCB(36 KA) with LSIG microprocessor based, Ics=100%Icu,4 nos. of 125 A 4P MCCB 25 ka with adjustable thermal setting Ics = 100% , 4 nos. 100A 4P MCCB 25 ka with adjustable thermal setting Ics = 100% ,02 nos 32A DP MCB 10kA,C series, 2 nos 63A 4P MCB 10kA,C series Instrument- (i)all the incoming feeders shall have phase indicating lamp with toggle switch & HRC fuse .(ii)All the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(ABB/Schneider/Siemens/Legrand)(iii) 1 set of digital multifunction meter(V+A+F+KwH+KVAR+KVAH+THD (ABB/Schneider/Siemens/Legrand)Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 360 | MAIN CONTROL Panel (VOLLY COURT,BASKET ball COURT): S/I/T&Commissioning of LT outdoor floor mounted cubical type electrical panelmade out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. .Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.Mandatory provision of cable alley is to be given.Incoming: 125 Amp. 4P MCCB 16 ka with with adjustable thermal setting, Ics=100%Icu ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) .,125 A 4P Manual Changeover Busbar : 04 numbers of 200Amps Aluminum busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. .Outgoing: 32 Amp.4P MCB 10 KA, C series -12 Nos,02 nos 32A DP MCB 10kA,C series, 4 nos 63A 4P MCB 10kA,C series, 2 nos 63A 4P MCCB 16 ka with with adjustable thermal setting, Ics=100%Icu ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) for solar.Instrument- (i)All the incoming feeders shall have phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-150)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 125/5A 3 nos class 1 type(iv) Provision of bidirectional meter for solar feeder.Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 361 | Design, Supply, Installation, Testing and Commissioning of Outdoor type with CRCA 2mm thick Mast Lighting Distribution Boards ( MLDB) for operation of the lights on Stadium masts incomer-32A, FP MCB, C series,10kA , 100 Amp.aluminum Bus Bar - 4 Nos. by color coded PVC sleeve & supported by suitable size DMC insulator and outgoing 6A DP MCB, C series,10kA-15 nos with one no.40kA type 2 3P+N SPD with 63A 4P MCB, C series, 10kA in the incomer and other accessories as per direction of Eng-in-charge.Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 362 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 363 | 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR MAIN PANEL) |
| 364 | 3.5 core x 300 sq mm Aluminium armoured Cable.(FOR MAIN PANEL) |
| 365 | 4C core 10 sqmm Aluminium armoured Cable |
| 366 | Supply and laying of 3C* 2.5sq mm Copper UnArmored Cable : SITC OF 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster |
| 367 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 368 | 3.5 core x 50 sq mm brass double compression gland and aluminium lugs |
| 369 | 3.5 core x300 sq mm gland and aluminium lugs |
| 370 | 4 core x 10 sq mm gland and aluminium lugs |
| 371 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 372 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 373 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 374 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.(To be used for laying of solar cable) |
| 375 | EARTHING |
| 376 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 377 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 378 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 379 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 380 | Providing and fixing 6 kg ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 381 | Supplying, installation, testing and commissioning of 2 kg capacity Eco friendly stored pressure type filled with HFC 236(Clean agent fire extinguisher) having zero ozone depletion potential clean agent fire extinguisher with safety seal, pressure gauge,controlable discharge mechanism helium leak detection tested and confirming to IS 15683 complete with initial charge including cost of all material & labour etc complete.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 382 | DATA NETWORK & CCTV |
| 383 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 384 | SITC of Cat6 I/O with single Face plate with GI modular box and keystone: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 385 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 386 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 387 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 388 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 389 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 390 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 391 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 392 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 393 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 394 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 395 | Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 396 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 397 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 398 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch |
| 399 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 400 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 401 | (2 VOLLYBALL COURT,3 BASKETBALL COURT) |
| 402 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Vakrangee/Valmont |
| 403 | Construction of pedestal type foundation with M20 grade concrete for pole 2000mm depth x 550mm length x 550mm breadth including all material and labour as per the direction of Engineer-in-charge. The structural calculation and civil foundation shall be duly approved by the competant authority from civil wing before execution of the work. |
| 404 | SITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement. Only sport series flood light will be accepted.Make- Panasonic/Philips/Bajaj/LT/Wipro/Crompton |
| 405 | Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) On grid inverter of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The On grid inverter shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply On grid inverter unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.g) SITC of outdoor(IP65) 63A 4P MCCB with bidrectional meter with 2mm CRCA hot dip galvanised panel asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years |
| 406 | P.H. WORKGallery And Common Facility Center (G+1):-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia PVC ASTM pipe (sch-80) |
| 407 | 32mm dia PVC ASTM pipe (sch-80) |
| 408 | 40mm dia PVC ASTM pipe (sch-80) |
| 409 | First Floor-40mm dia PVC ASTM pipe (sch-80) |
| 410 | 50 mm dia PVC ASTM pipe (sch-80) |
| 411 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.Ground Floor20mm dia CPVC pipe |
| 412 | 25mm dia CPVC pipe |
| 413 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall Ground Floor |
| 414 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. Ground Floor |
| 415 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor |
| 416 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041N Jaquar Make) |
| 417 | 15mm dia CP Long body bib cock(Jaquar)CON-CHR-107KN |
| 418 | 15mm dia CP Health Faucet (ALD-CHR- 577) |
| 419 | 15 mm dia CP WALL MIXER NON TELEPHONIC ( FLR-MCH-5219N Jaquar make ) |
| 420 | 15mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make ) |
| 421 | 20mm dia CP CONCEALED STOP COCK EXT HVY WTH WITH FLANGE(FLR-MCH-5083NJaquar) Make |
| 422 | 32mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm |
| 423 | 15 mm dia CP pillar cock auto closing system(Jaquar)-PRS-CHR-031 |
| 424 | Soap Dispenser with glass bottle(ACN-CHR-1135N) |
| 425 | CP soap Dish holder (Jaquar make)-AKP -ABR-35731P |
| 426 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 427 | 600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM |
| 428 | 25mm dia brass or gun metal fullway valve (Shakti Make) |
| 429 | 32mm dia brass or gun metal fullway valve (Shakti Make) |
| 430 | 50mm dia brass or gun metal fullway valve (Shakti Make) |
| 431 | 15mm dia CP flange |
| 432 | 15mm dia CP extension piece |
| 433 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477 |
| 434 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware Make) |
| 435 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme) |
| 436 | 110mm U-PVC door tee |
| 437 | 110mm U-PVC Plain tee |
| 438 | 110mm U-PVC door bend |
| 439 | 110mm U-PVC plain bend |
| 440 | 110mm dia U-PVC 'P' trap |
| 441 | 110mm dia U-PVC Plain Shoe Bend |
| 442 | 110mm dia U-PVC offset with out ear |
| 443 | 110mm dia U-PVC cowl |
| 444 | 125mm dia CP grating |
| 445 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall. |
| 446 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain with seat cover (Parryware/Hendware/Cera/Somany/Kerovit) |
| 447 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 448 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) (head)70002 |
| 449 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 450 | Under Counter Basin (560x455) (H)10095 white |
| 451 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror |
| 452 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Parryware / Hindware make) |
| 453 | 15mm dia urinal spreader |
| 454 | 32mm dia C.P. dome waste |
| 455 | Auto closing concealed urinal flush valve(Jaquar make)-PRS-CHR-077 |
| 456 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
| 457 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. |
| 458 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. Ground Floor |
| 459 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size. |
| 460 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size. |
| 461 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge,In Superstructure . |
| 462 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 463 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 464 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cum |
| 465 | Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. |
| 466 | Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge. |
| 467 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
| 468 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter. |
| 469 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 470 | Sinking of 200mmx150mm dia large Tube well(1 No.) :-Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore.Labour for Drilling of 200 mm dia bore 0mtr to 120mtr |
| 471 | Labour for Drilling of 150 mm dia bore 0mtr to 120mtr |
| 472 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 mtrs |
| 473 | Lowering of 200mm dia GI/P.V.C/MS casing pipes 31 mtr to 45 mtrs |
| 474 | Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe |
| 475 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH |
| 476 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). Submerssible Pump Set 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm. |
| 477 | DOL control panel |
| 478 | 2.50 sqmm cable |
| 479 | 32mm dia steel short piece |
| 480 | 32 mm dia HDPE Pipe |
| 481 | Bore Cap |
| 482 | C.I.Bracket |
| 483 | Rope Wire |
| 484 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 485 | Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber. |
| 486 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 487 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete |
| 488 | 160mm dia U-PVC Alround Concrete |
| 489 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 490 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm . |
| 491 | ---- do --- addl depth of 0.15m upto 0.90m |
| 492 | R.C.P.C.Manhole Cover |
| 493 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 494 | R.C.P.C.Manhole Cover |
| 495 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit. |
| 496 | Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00X1.50m at 1st Floor. 1NosSupplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 497 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 498 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete. RCC floor roof, chajja etc. |
| 499 | RCC Beam, Column, wall etc |
| 500 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. |
| 501 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.For 1nos. Tank |
| 502 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.For 1nos. Tank |
| 503 | Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge.For 1nos. Tank |
| 504 | Construction 1 nos 100 users RCC Septic tank :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 505 | - do - with addl. Depth of 1.5 m |
| 506 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 507 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 508 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 509 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 510 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 511 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.For Roof slab |
| 512 | For RCC wall |
| 513 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 514 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 515 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 516 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 517 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 518 | Dewatering with 5 H.P diesel engine pump during excavation |
| 519 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 520 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 521 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 522 | 110mm U-PVC cowl |
| 523 | Construction of 75000 Litres RCC Underground Reservoir of Inside size- 7.00 X 3.50 X2.30m :-Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
| 524 | -do- with Ist additional depth of 1.50 m over the initial lead and lift |
| 525 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 526 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 527 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement and shuttering. |
| 528 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 529 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC floor roof, chajja etc |
| 530 | RCC Beam, Column, wall etc |
| 531 | RCC Plinth bend/ Raft |
| 532 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. |
| 533 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 534 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 535 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail